Rapid analysis of iodinated X-ray contrast media in secondary and tertiary treated wastewater by direct injection liquid chromatography-tandem mass spectrometry

被引:54
作者
Busetti, Francesco [1 ]
Linge, Kathryn L. [1 ]
Blythe, Justin W. [1 ]
Heitz, Anna [1 ]
机构
[1] Curtin Univ Technol, Dept Appl Chem, CWQRC, Perth, WA 6845, Australia
基金
澳大利亚研究理事会;
关键词
LC-MS; Iodinated X-ray contrast media (ICM); Direct injection; Wastewater; Reverse osmosis; Water reuse;
D O I
10.1016/j.chroma.2008.10.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The iodinated X-ray contrast media are the most widely administered intravascular pharmaceuticals and are known to persist in the aquatic environment. A rapid method using direct injection liquid chromatography-tandem mass spectrometry (DI-LC-MS/MS) has been developed to measure eight ICM. These include iopamidol, iothalamic acid, diatrizoic acid, iohexol, iomeprol, iopromide, plus both ioxaglic acid and iodipamide, which have not previously reported in the literature. The LC-MS/MS fragmentation patterns obtained for each of the compounds are discussed and the fragments lost for each transition are identified. Matrix effects in post-RO water, MQ water, tap water and secondary effluent have also been investigated. The DI-LC-MS/MS method was validated on both secondary and tertiary treated wastewater, and applied to samples from an advanced activated sludge wastewater treatment plant (WWTP) and a water recycling facility using microfiltration (MF) and reverse osmosis (RO) in Perth, Western Australia. As well as providing information of the efficacy for RO to remove specific ICM, these results also represent the first values of ICM published in the literature for Australia. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:200 / 208
页数:9
相关论文
共 31 条
[1]  
[Anonymous], 2007, AUSTR GUIDELINES WAT
[2]   Factors affecting the rejection of organic solutes during NF/RO treatment - a literature review [J].
Bellona, C ;
Drewes, JE ;
Xu, P ;
Amy, G .
WATER RESEARCH, 2004, 38 (12) :2795-2809
[3]  
Bellona C, 2008, J AM WATER WORKS ASS, V100, P102
[4]   Determination of sixteen polycyclic aromatic hydrocarbons in aqueous and solid samples from an Italian wastewater treatment plant [J].
Busetti, F ;
Heitz, A ;
Cuomo, M ;
Badoer, S ;
Traverso, P .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1102 (1-2) :104-115
[5]   Behavior of pharmaceuticals, cosmetics and hormones in a sewage treatment plant [J].
Carballa, M ;
Omil, F ;
Lema, JM ;
Llompart, M ;
García-Jares, C ;
Rodríguez, I ;
Gómez, M ;
Ternes, T .
WATER RESEARCH, 2004, 38 (12) :2918-2926
[6]   X-ray contrast media - an overview [J].
Christiansen, C .
TOXICOLOGY, 2005, 209 (02) :185-187
[7]   Occurrence of iodinated X-ray contrast media in domestic effluents and their fate during indirect potable reuse [J].
Drewes, JE ;
Fox, P ;
Jekel, M .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2001, 36 (09) :1633-1645
[8]   STEREOISOMERISM IN CONTRAST-MEDIA IOVERSOL [J].
DUNN, J ;
LIN, Y ;
MILLER, D ;
ROGIC, M ;
NEUMANN, W ;
WOULFE, S ;
WHITE, D .
INVESTIGATIVE RADIOLOGY, 1990, 25 :S102-S103
[9]   CLARIFICATION OF THE LIMIT OF DETECTION IN CHROMATOGRAPHY [J].
FOLEY, JP ;
DORSEY, JG .
CHROMATOGRAPHIA, 1984, 18 (09) :503-511
[10]   Development of a multi-residue analytical methodology based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for screening and trace level determination of pharmaceuticals in surface and wastewaters [J].
Gros, Meritxell ;
Petrovic, Mira ;
Barcelo, Damia .
TALANTA, 2006, 70 (04) :678-690