Development of a multi-residue analytical methodology based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for screening and trace level determination of pharmaceuticals in surface and wastewaters

被引:626
作者
Gros, Meritxell
Petrovic, Mira
Barcelo, Damia
机构
[1] CSIC, Dept Environm Chem, IIQAB, ES-08034 Barcelona, Spain
[2] ICREA, Barcelona, Spain
关键词
liquid chromatography-tandem mass spectrometry; pharmaceuticals; surface and wastewater analysis; multi-residue analytical method; ion suppression;
D O I
10.1016/j.talanta.2006.05.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes development, optimization and validation of a method for the simultaneous determination of 29 multi-class pharmaceuticals using off line solid phase extraction (SPE) followed by liquid chromatography-triple quadrupole mass spectrometry (LC-MS-MS). Target compounds include analgesics and non-steroidal anti-inflammatories (NSAIDs), lipid regulators, psychiatric drugs, anti-histaminics, anti-ulcer agent, antibiotics and beta-blockers. Recoveries obtained were generally higher than 60% for both surface and wastewaters, with exception of several compounds that yielded lower, but still acceptable recoveries: ranitidine (50%), sotalol (50%), famotidine (50%) and mevastatin (34%). The overall variability of the method was below 15%, for all compounds and all tested matrices. Method detection limits (MDL) varied between I and 30 ng/L and from 3 to 160 ng/L for surface and wastewaters, respectively. The precision of the method, calculated as relative standard deviation (R.S.D.), ranged from 0.2 to 6% and from 1 to 11% for inter and intra-day analysis, respectively. A detailed study of matrix effects was performed in order to evaluate the suitability of different calibration approaches (matrix-matched external calibration, internal calibration, extract dilution) to reduce analyte suppression or enhancement during instrumental analysis. The main advantages and drawbacks of each approach are demonstrated, justifying the selection of internal standard calibration as the most suitable approach for our study. The developed analytical method was successfully applied to the analysis of pharmaceutical residues in WWTP influents and effluents, as well as in river water. For both, river and wastewaters, the most ubiquitous compounds belonged to the group of anti-inflammatories and analgesics, antibiotics, the lipid regulators being acetaminophen, trimethoprim, ibuprofen, ketoprofen, atenolol, propranolol, mevastatin, carbarnazepine and ranitidine the most frequently detected compounds. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:678 / 690
页数:13
相关论文
共 38 条
[1]   The ECHO technique -: the more effective way of data evaluation in liquid chromatography-tandem mass spectrometry analysis [J].
Alder, L ;
Lüderitz, S ;
Lindtner, K ;
Stan, HJ .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1058 (1-2) :67-79
[2]   Countering matrix effects in environmental liquid chromatography-electrospray ionization tandem mass spectrometry water analysis for endocrine disrupting chemicals [J].
Benijts, T ;
Dams, R ;
Lambert, W ;
De Leenheer, A .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1029 (1-2) :153-159
[3]   Determination of pharmaceutical compounds in surface- and ground-water samples by solid-phase extraction and high-performance liquid chromatography-electrospray ionization mass spectrometry [J].
Cahill, JD ;
Furlong, ET ;
Burkhardt, MR ;
Kolpin, D ;
Anderson, LG .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1041 (1-2) :171-180
[4]   Behavior of pharmaceuticals, cosmetics and hormones in a sewage treatment plant [J].
Carballa, M ;
Omil, F ;
Lema, JM ;
Llompart, M ;
García-Jares, C ;
Rodríguez, I ;
Gómez, M ;
Ternes, T .
WATER RESEARCH, 2004, 38 (12) :2918-2926
[5]  
CASTIGLIONI S, 2005, J CHROMATOGR A
[6]   Pharmaceuticals and personal care products in the environment: Agents of subtle change? [J].
Daughton, CG ;
Ternes, TA .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1999, 107 :907-938
[7]   LC-MS2 trace analysis of antimicrobials in water, sediment and soil [J].
Díaz-Cruz, MS ;
Barceló, D .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (07) :645-657
[8]  
Díaz-Cruz S, 2004, HANDB ENVIRON CHEM, V5, P227, DOI 10.1007/b97180
[9]   Determination of drugs in surface water and wastewater samples by liquid chromatography-mass spectrometry:: methods and preliminary results including toxicity studies with Vibrio fischeri [J].
Farré, ML ;
Ferrer, I ;
Ginebreda, A ;
Figueras, M ;
Olivella, L ;
Tirapu, L ;
Vilanova, M ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 2001, 938 (1-2) :187-197
[10]   Liquid chromatography-tandem mass spectrometry for performing confirmatory analysis of veterinary drugs in animal-food products [J].
Gentili, A ;
Perret, D ;
Marchese, S .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (07) :704-733