Improved Safety and Reduction in Stent Thrombosis Associated With Biodegradable Polymer-Based Biolimus-Eluting Stents Versus Durable Polymer-Based Sirolimus-Eluting Stents in Patients With Coronary Artery Disease Final 5-Year Report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) Randomized, Noninferiority Trial

被引:286
作者
Serruys, Patrick W. [1 ]
Farooq, Vasim [1 ]
Kalesan, Bindu [2 ,3 ]
de Vries, Ton [4 ]
Buszman, Pawel [5 ]
Linke, Axel [6 ]
Ischinger, Thomas [7 ]
Klauss, Volker [8 ]
Eberli, Franz [9 ]
Wijns, William [10 ]
Morice, Marie Claude [11 ]
Di Mario, Carlo [12 ]
Corti, Roberto [13 ]
Antoni, Diethmar [14 ]
Sohn, Hae Y. [15 ]
Eerdmans, Pedro [16 ]
Rademaker-Havinga, Tessa [4 ]
van Es, Gerrit-Anne [4 ]
Meier, Bernhard [17 ]
Jueni, Peter [2 ,3 ]
Windecker, Stephan [17 ]
机构
[1] Erasmus Univ, Thoraxctr, Med Ctr, NL-3000 DR Rotterdam, Netherlands
[2] Univ Bern, Dept Cardiol, CTU Bern, Bern, Switzerland
[3] Univ Bern, Inst Social & Prevent Med, Dept Cardiol, Bern, Switzerland
[4] Cardialysis, Rotterdam, Netherlands
[5] Amer Heart Poland, Ustron, Poland
[6] Herzzentrum Leipzig, Leipzig, Germany
[7] Kardiol Zentrum, Munich, Germany
[8] Kardiol Innenstadt, Munich, Germany
[9] Triemli Spital, Dept Cardiol, Zurich, Switzerland
[10] Onze Lieve Vrouw Hosp, Dept Cardiol, Aalst, Belgium
[11] Inst Hosp Jacques Cartier, Inst Cardiovasc Paris Sud, Massy, France
[12] Royal Brompton Hosp, London SW3 6LY, England
[13] Univ Zurich Hosp, CH-8091 Zurich, Switzerland
[14] Hosp Bogenhausen, Dept Cardiol, Munich, Germany
[15] Univ Hosp Munich Innenstadt, Dept Cardiol, Munich, Germany
[16] Biosensors Europe SA, Morges, Switzerland
[17] Univ Bern, Dept Cardiol, Bern, Switzerland
关键词
biodegradable polymer; drug-eluting stents; durable polymer; stent thrombosis; BARE-METAL STENTS; MYOCARDIAL-INFARCTION; TASK-FORCE; FOLLOW-UP; CLINICAL PRESENTATION; PRACTICE GUIDELINES; BYPASS-SURGERY; SYNTAX SCORE; REVASCULARIZATION; INTERVENTION;
D O I
10.1016/j.jcin.2013.04.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial. Background The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES. Methods The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat. Results At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority <0.0001, p for superiority = 0.069). The BES was associated with a significant reduction in the more comprehensive patient-orientated composite endpoint of all-cause death, any MI, and all-cause revascularization (297 [35.1%] vs. 339 [40.4%], RR: 0.84 [95% CI: 0.71 to 0.98], p for superiority = 0.023). A significant reduction in very late definite ST from 1 to 5 years was evident with the BES (n = 5 [0.7%] vs. n = 19 [2.5%], RR: 0.26 [95% CI: 0.10 to 0.68], p = 0.003), corresponding to a significant reduction in ST-associated clinical events (primary endpoint) over the same time period (n = 3 of 749 vs. n = 14 of 738, RR: 0.20 [95% CI: 0.06 to 0.71], p = 0.005). Conclusions The safety benefit of the biodegradable polymer BES, compared with the durable polymer SES, was related to a significant reduction in very late ST (>1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220) (C) 2013 by the American College of Cardiology Foundation
引用
收藏
页码:777 / 789
页数:13
相关论文
共 50 条
[1]   Clinical Presentation, Management, and Outcomes of Angiographically Documented Early, Late, and Very Late Stent Thrombosis [J].
Armstrong, Ehrin J. ;
Feldman, Dmitriy N. ;
Wang, Tracy Y. ;
Kaltenbach, Lisa A. ;
Yeo, Khung-Keong ;
Wong, S. Chiu ;
Spertus, John ;
Shaw, Richard E. ;
Minutello, Robert M. ;
Moussa, Issam ;
Ho, Kalon K. L. ;
Rogers, Jason H. ;
Shunk, Kendrick A. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (02) :131-140
[2]   Short- and Long-Term Outcomes With Drug-Eluting and Bare-Metal Coronary Stents A Mixed-Treatment Comparison Analysis of 117 762 Patient-Years of Follow-Up From Randomized Trials [J].
Bangalore, Sripal ;
Kumar, Sunil ;
Fusaro, Mario ;
Amoroso, Nicholas ;
Attubato, Michael J. ;
Feit, Frederick ;
Bhatt, Deepak L. ;
Slater, James .
CIRCULATION, 2012, 125 (23) :2873-+
[3]   Stent thrombosis late after implantation of first-generation drug-eluting stents - A cause for concern [J].
Camenzind, Edoardo ;
Steg, P. Gabriel ;
Wijns, William .
CIRCULATION, 2007, 115 (11) :1440-1455
[4]   Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation [J].
Cook, Stephane ;
Wenaweser, Peter ;
Togni, Mario ;
Billinger, Michael ;
Morger, Cyrill ;
Seiler, Christian ;
Vogel, Rolf ;
Hess, Otto ;
Meier, Bernhard ;
Windecker, Stephan .
CIRCULATION, 2007, 115 (18) :2426-2434
[5]   Correlation of Intravascular Ultrasound Findings With Histopathological Analysis of Thrombus Aspirates in Patients With Very Late Drug-Eluting Stent Thrombosis [J].
Cook, Stephane ;
Ladich, Elena ;
Nakazawa, Gaku ;
Eshtehardi, Parham ;
Neidhart, Michel ;
Vogel, Rolf ;
Togni, Mario ;
Wenaweser, Peter ;
Billinger, Michael ;
Seiler, Christian ;
Gay, Steffen ;
Meier, Bernhard ;
Pichler, Werner J. ;
Jueni, Peter ;
Virmani, Renu ;
Windecker, Stephan .
CIRCULATION, 2009, 120 (05) :391-399
[6]  
Cutlip DE, 2001, CIRCULATION, V103, P1967
[7]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[8]   Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice:: data from a large two-institutional cohort study [J].
Daemen, Joost ;
Wenaweser, Peter ;
Tsuchida, Keiichi ;
Abrecht, Linda ;
Sophia, Vaina ;
Morger, Cyrill ;
Kukreja, Neville ;
Jueni, Peter ;
Sianos, Georgios ;
Hellige, Gerrit ;
van Domburg, Ron T. ;
Hess, Otto M. ;
Boersma, Eric ;
Meier, Bernhard ;
Windecker, Stephan ;
Serruys, Patrick W. .
LANCET, 2007, 369 (9562) :667-678
[9]   The SYNTAX Score and SYNTAX-Based Clinical Risk Scores [J].
Farooq, Vasim ;
Brugaletta, Salvatore ;
Serruys, Patrick W. .
SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2011, 23 (02) :99-105
[10]   Prediction of 1-Year Mortality in Patients With Acute Coronary Syndromes Undergoing Percutaneous Coronary Intervention Validation of the Logistic Clinical SYNTAX (Synergy Between Percutaneous Coronary Interventions With Taxus and Cardiac Surgery) Score [J].
Farooq, Vasim ;
Vergouwe, Yvonne ;
Genereux, Philippe ;
Bourantas, Christos V. ;
Palmerini, Tullio ;
Caixeta, Adriano ;
Garcia-Garcia, Hector M. ;
Diletti, Roberto ;
Morel, Marie-angele ;
McAndrew, Thomas C. ;
Kappetein, Arie Pieter ;
Valgimigli, Marco ;
Windecker, Stephan ;
Dawkins, Keith D. ;
Steyerberg, Ewout W. ;
Serruys, Patrick W. ;
Stone, Gregg W. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (07) :737-745