Compensation for nonuniform attenuation in SPECT brain imaging

被引:10
作者
Glick, SJ
King, MA
Pan, TS
Soares, EJ
机构
[1] University of Massachusetts, Medical Center, Worcester
关键词
D O I
10.1109/23.491524
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Accurate compensation for photon attenuation is needed to perform quantitative brain single-photon-emission computed tomographic (SPECT) imaging, Bellini's attenuation compensation method has been used with a nonuniform attenuation map to account for the nonuniform attenuation properties of the head, Simulation studies using a three-dimensional (3-D) digitized anthropomorphic brain phantom were conducted to compare quantitative accuracy of reconstructions obtained with the nonuniform Bellini method to that obtained with the Chang method and to iterative reconstruction using maximum-likelihood expectation maximization (ML-EM), Using the Chang method and assuming the head to be a uniform attenuator gave reconstructions with an average bias of approximately 6-8%, whereas using the Bellini or the iterative ML-EM method with a nonuniform attenuation map gave an average bias of approximately 1%. The computation time required to implement nonuniform attenuation compensation with the Bellini algorithm is approximately equivalent to the time required to perform one iteration of ML-EM. Thus, using the Bellini method with a nonuniform attenuation map provides accurate compensation for photon attenuation within the head, and the method can be implemented in computation times suitable for routine clinical use.
引用
收藏
页码:737 / 750
页数:14
相关论文
共 31 条
[1]  
ABI-DARGHAM A, 1994, J NUCL MED, V35, P228
[2]   COMPENSATION OF TISSUE ABSORPTION IN EMISSION TOMOGRAPHY [J].
BELLINI, S ;
PIACENTINI, M ;
CAFFORIO, C ;
ROCCA, F .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1979, 27 (03) :213-218
[4]   NONITERATIVE COMPENSATION FOR THE DISTANCE-DEPENDENT DETECTOR RESPONSE AND PHOTON ATTENUATION IN SPECT IMAGING [J].
GLICK, SJ ;
PENNEY, BC ;
KING, MA ;
BYRNE, CL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) :363-374
[5]   CHARACTERIZATION OF THE MODULATION TRANSFER-FUNCTION OF DISCRETE FILTERED BACKPROJECTION [J].
GLICK, SJ ;
KING, MA ;
PENNEY, BC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1989, 8 (02) :203-213
[6]   THE EFFECT OF INTRINSIC ATTENUATION CORRECTION METHODS ON THE STATIONARITY OF THE 3-D MODULATION TRANSFER-FUNCTION OF SPECT [J].
GLICK, SJ ;
HAWKINS, WG ;
KING, MA ;
PENNEY, BC ;
SOARES, EJ ;
BYRNE, CL .
MEDICAL PHYSICS, 1992, 19 (04) :1105-1112
[7]  
GONG W, 1994, J NUCL MED, V39
[8]   AN ATTENUATED PROJECTOR BACKPROJECTOR FOR ITERATIVE SPECT RECONSTRUCTION [J].
GULLBERG, GT ;
HUESMAN, RH ;
MALKO, JA ;
PELC, NJ ;
BUDINGER, TF .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (08) :799-816
[9]   THE USE OF FILTERING METHODS TO COMPENSATE FOR CONSTANT ATTENUATION IN SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY [J].
GULLBERG, GT ;
BUDINGER, TF .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (02) :142-157
[10]   THE CIRCULAR HARMONIC TRANSFORM FOR SPECT RECONSTRUCTION AND BOUNDARY-CONDITIONS ON THE FOURIER-TRANSFORM OF THE SINOGRAM [J].
HAWKINS, WG ;
LEICHNER, PK ;
YANG, NC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (02) :135-148