Development of QRS detection algorithm designed for wearable cardiorespiratory system

被引:57
作者
Adnane, Mourad [1 ]
Jiang, Zhongwei [1 ]
Choi, Samjin [1 ]
机构
[1] Yamaguchi Univ, Dept Mech Engn, Yamaguchi 7558611, Japan
关键词
QRS detection; HRV; RR interval; Cardiorespiratory belt sensor; TIME; ECG;
D O I
10.1016/j.cmpb.2008.07.010
中图分类号
TP39 [计算机的应用];
学科分类号
080201 [机械制造及其自动化];
摘要
An in-home sleep monitoring system was developed previously in our laboratory for monitoring electrocardiography (ECG) and respiratory signals. However, the ECG signal acquired with this system is prone to high-grade noise caused by motion artifact. Since the detection of the QRS complexes with high accuracy is very important in a computer-based analysis of the ECG, a high accuracy QRS detection algorithm is developed and based on the combination of heart rate indicators and morphological ECG features. The proposed algorithm is tested both on 16h data acquired using the two sensors of our cardiorespiratory belt system, i.e., the polyvinylidene fluoride (PVDF) film and the conductive fabric sheets, and on all 48 records of the MIT/BIH Arrhythmia Database. Satisfying results are obtained for both databases, the sensitivity Se and positive predictivity P, were calculated for each case and results show S-e=[96.98%, 93.76%] and P+=[97.81%, 99.48%] for conductive fabric and PVDF film sensors, respectively, and S-e=99.77% and P+=99.64% in the case of the MIT/BIH Arrhythmia Database. Further, heart rate variability (HRV) measures were calculated using our system and a commercial system. A comparison between systems' results is done to show the usefulness of our developed algorithm used with our cardiorespiratory belt sensor. (c) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:20 / 31
页数:12
相关论文
共 18 条
[1]
Automatic ectopic beat elimination in short-term heart rate variability measurement [J].
Acar, B ;
Savelieva, I ;
Hemingway, H ;
Malik, M .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2000, 63 (02) :123-131
[2]
[Anonymous], MIT-BIH Arrhythmia Database
[3]
ARNER AE, 2002, REPRODUCIBILITY SHOR, P49
[4]
BJERREGAARD P, 1983, EUR HEART J, V4, P44
[5]
High-resolution QRS fiducial point corrections in sparsely sampled ECG recordings [J].
Bragge, T ;
Tarvainen, MP ;
Ranta-Aho, PO ;
Karjalainen, PA .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (05) :743-751
[6]
Camm AJ, 1996, EUR HEART J, V17, P354
[7]
A real-time QRS detection method based on moving-averaging incorporating with wavelet denoising [J].
Chen, Szi-Wen ;
Chen, Hsiao-Chen ;
Chan, Hsiao-Lung .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2006, 82 (03) :187-195
[8]
A novel wearable sensor device with conductive fabric and PVDF film for monitoring cardiorespiratory signals [J].
Choi, SJ ;
Jiang, ZW .
SENSORS AND ACTUATORS A-PHYSICAL, 2006, 128 (02) :317-326
[9]
Real time electrocardiogram QRS detection using combined adaptive threshold [J].
Christov, Ivaylo I. .
BIOMEDICAL ENGINEERING ONLINE, 2004, 3 (1)
[10]
DECHAZAL P, 2003, IEEE T BIOMEDICAL EN, V50