Spectrally resolved magnetic resonance imaging of a xenon biosensor

被引:68
作者
Hilty, C [1 ]
Lowery, TJ
Wemmer, DE
Pines, A
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Lab, Div Mat Sci, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Lawrence Berkeley Lab, Phys Biosci Div, Berkeley, CA 94720 USA
关键词
biosensors; cage compounds; imaging agents; magnetic resonance imaging; xenon;
D O I
10.1002/anie.200502693
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Going hyper: A continuous flow of water saturated with hyperpolarized xenon through a glass tube assembly containing a xenon biosensor attached through its biotin tag to immobilized avidin-agarose beads (see picture) packed in between two frits results in distinct NMR signals that allow detection of the immobilized avidin analyte with high sensitivity. (Figure Presented) © 2006 Wiley-VCH Verlag GmbH & Co. KGaA.
引用
收藏
页码:70 / 73
页数:4
相关论文
共 14 条
[1]  
ALBERT MS, 1994, NATURE, V370, P199, DOI 10.1038/370199a0
[2]  
Callaghan P.T., 1991, Principles of nuclear magnetic resonance microscopy, V1st
[3]   CYCLOTRIVERATRYLENES AND CRYPTOPHANES [J].
COLLET, A .
TETRAHEDRON, 1987, 43 (24) :5725-5759
[4]   Molecular imaging with endogenous substances [J].
Golman, K ;
Ardenær-Larsen, JH ;
Petersson, JS ;
Månsson, S ;
Leunbach, I .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (18) :10435-10439
[5]   In vivo NMR and MRI using injection delivery of laser-polarized xenon [J].
Goodson, BM ;
Song, YQ ;
Taylor, RE ;
Schepkin, VD ;
Brennan, KM ;
Chingas, GC ;
Budinger, TF ;
Navon, G ;
Pines, A .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (26) :14725-14729
[6]   NMR-based biosensing with optimized delivery of polarized 129Xe to solutions [J].
Han, SI ;
Garcia, S ;
Lowery, TJ ;
Ruiz, EJ ;
Seeley, JA ;
Chavez, L ;
King, DS ;
Wemmer, DE ;
Pines, A .
ANALYTICAL CHEMISTRY, 2005, 77 (13) :4008-4012
[7]   NMR RECEIVER - DESCRIPTION AND ANALYSIS OF DESIGN [J].
HOULT, DI .
PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY, 1978, 12 :41-77
[8]   A continuously recirculating optical pumping apparatus for high xenon polarization and surface NMR studies [J].
Knagge, K ;
Prange, J ;
Raftery, D .
CHEMICAL PHYSICS LETTERS, 2004, 397 (1-3) :11-16
[9]   Applications of laser-polarized 129Xe to biomolecular assays [J].
Lowery, TJ ;
Rubin, SM ;
Ruiz, EJ ;
Spence, MM ;
Winssinger, N ;
Schultz, PG ;
Pines, A ;
Wemmer, DE .
MAGNETIC RESONANCE IMAGING, 2003, 21 (10) :1235-1239
[10]  
LOWERY TJ, 2005, IN PRESS CHEMBIOCHEM