The CdTe detector module and its imaging performance

被引:32
作者
Mori, I [1 ]
Takayama, T [1 ]
Motomura, N [1 ]
机构
[1] Toshiba Co Ltd, Med Syst Co, CT & Nucl Med Syst Dev Dept, Med Syst R&D Ctr, Otawara, Tochigi 3248550, Japan
关键词
semiconductor; detector; single photon emission computed tomography; energy resolution; cadmium telluride;
D O I
10.1007/BF02988500
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In recent years investigations into the application of semiconductor detector technology in gamma cameras have become active world-wide. The reason for this burst of activity is the expectation that the semiconductor-based gamma camera would outperform the conventional Anger-type gamma camera with a large scintillator and photomultipliers. Nevertheless, to date, it cannot be said that this expectation has been met. Methods: While most of the studies have used CZT (Cadmium Zinc Telluride) as the semiconductor material, we designed and fabricated an experimental detector module of CdTe (Cadmium Telluride). The module consists of 512 elements and its pixel pitch is 1.6 mm. We have evaluated its energy resolution, planar image performance, single photon emission computed tomography (SPECT) image performance and time resolution for coincidence detection. Results: The average energy resolution was 5.5% FWHM at 140 keV. The intrinsic spatial resolution was 1.6 mm. The quality of the phantom images, both planar and SPECT, was visually superior to that of the Anger-type gamma camera. The quantitative assessment of SPECT images showed accuracy far better than that of the Anger-type camera. The coincidence time resolution was 8.6 ns. All measurements were done at room temperature, and the polarization effect that had been the biggest concern for CdTe was not significant. Conclusion: The results indicated that the semiconductor-based gamma camera is superior in performance to the Anger-type and has the possibility of being used as a positron emission computed tomography (PET) scanner.
引用
收藏
页码:487 / 494
页数:8
相关论文
共 16 条
[1]   CHARGE-TRANSPORT IN ARRAYS OF SEMICONDUCTOR GAMMA-RAY DETECTORS [J].
BARRETT, HH ;
ESKIN, JD ;
BARBER, HB .
PHYSICAL REVIEW LETTERS, 1995, 75 (01) :156-159
[2]   TIME-DEPENDENT POLARIZATION OF CDTE GAMMA-RAY DETECTORS [J].
BELL, RO ;
ENTINE, G ;
SERREZE, HB .
NUCLEAR INSTRUMENTS & METHODS, 1974, 117 (01) :267-271
[3]  
BENNETT PR, 1997, IEEE T NUCL SCI S C, P561
[4]   CdZnTe solid-state gamma camera [J].
Butler, JF ;
Lingren, CL ;
Friesenhahn, SJ ;
Doty, FP ;
Ashburn, WL ;
Conwell, RL ;
Augustine, FL ;
Apotovsky, B ;
Pi, B ;
Collins, T ;
Zhao, S ;
Isaacson, C .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :359-363
[5]   Growth and characterization of CdTe single crystals for radiation detectors [J].
Funaki, M ;
Ozaki, T ;
Satoh, K ;
Ohno, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2) :120-126
[6]   CdTe and CdZnTe semiconductor gamma detectors equipped with ohmic contacts [J].
Lachish, U .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2) :146-149
[7]   Progress in the development of large-area modular 64 x 64 CdZnTe imaging arrays for nuclear medicine [J].
Matherson, KJ ;
Barber, HB ;
Barrett, HH ;
Eskin, JD ;
Dereniak, EL ;
Marks, DG ;
Woolfenden, JM ;
Young, ET ;
Augustine, FL .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :354-358
[8]  
Matsumoto C., 1997, IEEE INT NUCL SCI S, V1, P569
[9]   Charge collection efficiency and space charge formation in CdTe gamma and X-ray detectors [J].
Matz, R ;
Weidner, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 406 (02) :287-298
[10]   Development of high-resolution CdTe radiation detectors in a new M-π-n design [J].
Niraula, M ;
Mochizuki, D ;
Aoki, T ;
Tomita, Y ;
Nihashi, T ;
Hatanaka, Y .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) :1237-1241