Iliofemoral arterial occlusive disease: Contrast-enhanced MR angiography for preinterventional evaluation and follow-up after stent placement

被引:49
作者
Link, J
Steffens, JC
Brossman, J
Graessner, J
Hackethal, S
Heller, M
机构
[1] Univ Kiel, Dept Radiol, D-24098 Kiel, Germany
[2] Siemens Med Syst Inc, Hamburg, Germany
关键词
arteries; grafts and prostheses; stenosis or obstruction; magnetic resonance (MR); comparative studies; vascular studies; stents and prostheses;
D O I
10.1148/radiology.212.2.r99au24371
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the efficacy of contrast material-enhanced magnetic resonance (MR) angiography for the diagnosis of peripheral arterial occlusion and follow-up after stent placement. MATERIALS AND METHODS: Sixty-seven patients (21 women, 46 men; mean age, 64.6 years) were examined. Digital subtraction angiography and contrast-enhanced MR angiography were performed in 28 patients for preinterventional evaluation of iliofemoral arterial occlusion and in 39 patients for follow-up after stent placement in the iliac or femoral arteries, which had been performed several months before. RESULTS: All 24 occlusions were correctly diagnosed with contrast-enhanced MR angiography. Of the 59 stenoses, 36 were greater than 50% and 23 were 50% or less. Sensitivity and specificity for the detection of stenoses greater than 50% were 100% and 83%, respectively. Patency of the different stents was determined correctly with contrast-enhanced MR, angiography. Some stents caused signal intensity dropout, which made MR evaluation of stents difficult. Generally, these signal intensity artifacts were most severe in stainless steel stents and mild in some nitinol stents. CONCLUSION: Contrast enhanced MR angiography is comparable to digital subtraction angiography for the detection of stenosis greater than 50% and occlusion in the iliofemoral arteries. Stent patency can be determined, but contrast-enhanced MR angiography is not suitable for stent evaluation owing to signal intensity dropout; however, it provides information about the vascular anatomic areas proximal and distal to the stent.
引用
收藏
页码:371 / 377
页数:7
相关论文
共 22 条
  • [11] BREATH-HOLD GADOLINIUM-ENHANCED MR-ANGIOGRAPHY OF THE ABDOMINAL-AORTA AND ITS MAJOR BRANCHES
    PRINCE, MR
    NARASIMHAM, DL
    STANLEY, JC
    CHENEVERT, TL
    WILLIAMS, DM
    MARX, V
    CHO, KJ
    [J]. RADIOLOGY, 1995, 197 (03) : 785 - 792
  • [12] DYNAMIC GADOLINIUM-ENHANCED 3-DIMENSIONAL ABDOMINAL MR ARTERIOGRAPHY
    PRINCE, MR
    YUCEL, EK
    KAUFMAN, JA
    HARRISON, DC
    GELLER, SC
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (06): : 877 - 881
  • [13] GADOLINIUM-ENHANCED MR AORTOGRAPHY
    PRINCE, MR
    [J]. RADIOLOGY, 1994, 191 (01) : 155 - 164
  • [14] FEMORAL MR-ANGIOGRAPHY VERSUS CONVENTIONAL ANGIOGRAPHY - PRELIMINARY-RESULTS
    QUINN, SF
    DEMLOW, TA
    HALLIN, RW
    EIDEMILLER, LR
    SZUMOWSKI, J
    [J]. RADIOLOGY, 1993, 189 (01) : 181 - 184
  • [15] MR-ANGIOGRAPHY OF THE PERIPHERAL VASCULATURE
    SCHNALL, MD
    HOLLAND, GA
    BAUM, RA
    COPE, C
    SCHIEBLER, ML
    CARPENTER, JP
    [J]. RADIOGRAPHICS, 1993, 13 (04) : 920 - 930
  • [16] SCHUERMANN K, 1997, CARDIOVASC INTER RAD, V20, P59
  • [17] SHETTY AN, 1995, AJR, V165, P990
  • [18] Three-dimensional gadolinium-enhanced MR angiography for aortoiliac inflow assessment plus renal artery screening in a single breath hold
    Snidow, JJ
    Johnson, MS
    Harris, VJ
    Margosian, PM
    Aisen, AM
    Lalka, SG
    Cikrit, DF
    Trerotola, SO
    [J]. RADIOLOGY, 1996, 198 (03) : 725 - 732
  • [19] Cardiac-gated two-dimensional phase-contrast MR angiography of lower extremity occlusive disease
    Steffens, CJ
    Link, J
    MullerHulsbeck, S
    Freund, M
    Brinkmann, G
    Heller, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (03) : 749 - 754
  • [20] Contrast-enhanced, K-space-centered, breath-hold MR angiography of the renal arteries and the abdominal aorta
    Steffens, JC
    Link, J
    Grassner, J
    MuellerHuelsbeck, S
    Brinkmann, G
    Reuter, M
    Heller, M
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (04) : 617 - 622