On-column trace enrichment by sequential frontal and elution electrochromatography - II. Enhancement of sensitivity by segmented capillaries with z-cell configuration-application to the detection of dilute samples of moderately polar and nonpolar pesticides

被引:20
作者
Tegeler, T [1 ]
El Rassi, Z [1 ]
机构
[1] Oklahoma State Univ, Dept Chem, Stillwater, OK 74078 USA
关键词
electrochromatography; sensitivity; sample handling; pesticides; carbamates; pyrethroids;
D O I
10.1016/S0021-9673(01)01493-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An on-column trace enrichment method for capillary electrochromatography of dilute samples is described. It involves the sequential use of frontal and elution electrochromatography on a segmented capillary column comprising of two contiguous segments each packed with a different sorbent. While the entering segment is for preconcentration by frontal electrochromatography the second segment is much longer and is meant for separation of the enriched analytes in the subsequent elution electrochromatography step. The preconcentration segment is usually packed with a sorbent that affords the highest affinity towards the solutes of interest while the separation segment is packed with a stationary phase that exhibits the highest selectivity and separation efficiency for the analytes. The detection is performed in the UV using a z-cell configuration for achieving an increased path length for detection. The effectiveness of this on-column trace enrichment is demonstrated on dilute samples of moderately polar solutes (e.g., carbamate insecticides) and nonpolar solutes (e.g., pyrethroid insecticides). Under optimal frontal and elution electrochromatography conditions, 817- and 1100-fold sensitivity increase are achieved for permethrin (a pyrethroid insecticide) and methiocarb (a carbamate insecticide), respectively, with a UV detector. The method is demonstrated with real water samples (e.g., tap and lake water samples) spiked with carbamate and pyrethroid insecticides. The limits of detection for the pesticides achieved in tap and lake waters reached 10(-8) to 10(-9) M. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:267 / 279
页数:13
相关论文
共 20 条
[1]  
Breadmore MC, 2001, ELECTROPHORESIS, V22, P2464
[2]   Validation of new solid-phase extraction materials for the selective enrichment of organic contaminants from environmental samples [J].
Ferrer, I ;
Barceló, D .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (03) :180-192
[3]   Recent developments in polymer-based sorbents for solid-phase extraction [J].
Huck, CW ;
Bonn, GK .
JOURNAL OF CHROMATOGRAPHY A, 2000, 885 (1-2) :51-72
[4]   FUNDAMENTAL AND PRACTICAL ASPECTS OF COUPLED CAPILLARIES FOR THE CONTROL OF ELECTROOSMOTIC FLOW IN CAPILLARY ZONE ELECTROPHORESIS OF PROTEINS [J].
NASHABEH, W ;
ELRASSI, Z .
JOURNAL OF CHROMATOGRAPHY, 1993, 632 (1-2) :157-164
[5]  
NASHABEH W, 1992, HRC-J HIGH RES CHROM, V15, P289
[6]  
Osbourn DM, 2000, ELECTROPHORESIS, V21, P2768, DOI 10.1002/1522-2683(20000801)21:14<2768::AID-ELPS2768>3.0.CO
[7]  
2-P
[8]   Solid-phase extraction for multiresidue analysis of organic contaminants in water [J].
Pichon, V .
JOURNAL OF CHROMATOGRAPHY A, 2000, 885 (1-2) :195-215
[9]   Sample stacking of cationic and anionic analytes in capillary electrophoresis [J].
Quirino, JP ;
Terabe, S .
JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (01) :119-135
[10]   Capillary electrochromatography of steroids - Increased sensitivity by on-line concentration and comparison with high-performance liquid chromatography [J].
Stead, DA ;
Reid, RG ;
Taylor, RB .
JOURNAL OF CHROMATOGRAPHY A, 1998, 798 (1-2) :259-267