A two-dimensional quadrupole ion trap mass spectrometer

被引:566
作者
Schwartz, JC
Senko, MW
Syka, JEP
机构
[1] Thermo Finnigan, LC & LC MS Div, San Jose, CA 95134 USA
[2] Thermo Finnigan, LC & LC MS Div, Charlottesville, VA USA
关键词
D O I
10.1016/S1044-0305(02)00384-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of a linear or two-dimensional (2-D) quadrupole ion trap as a high performance mass spectrometer is demonstrated. Mass analysis is performed by ejecting ions out a slot in one of the rods using the mass selective instability mode of operation. Resonance ejection and excitation are utilized to enhance mass analysis and to allow isolation and activation of ions for MS' capability. Improved trapping efficiency and increased ion capacity are observed relative to a three-dimensional (3-D) ion trap with similar mass range. Mass resolution comparable to 3-D traps is readily achieved, including high resolution at slower scan rates, although adequate mechanical tolerance of the trap structure is a requirement. Additional advantages of 2-D over 3-D ion traps are also discussed and demonstrated. (J Am Soc Mass Spectrom 2002, 13, 659-669) (C) 2002 American Society for Mass Spectrometry.
引用
收藏
页码:659 / 669
页数:11
相关论文
共 35 条
[1]   Design and performance of an ESI interface for selective external ion accumulation coupled to a Fourier transform ion cyclotron mass spectrometer [J].
Belov, ME ;
Nikolaev, EN ;
Anderson, GA ;
Udseth, HR ;
Conrads, TP ;
Veenstra, TD ;
Masselon, CD ;
Gorshkov, MV ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2001, 73 (02) :253-261
[2]   ELIMINATION OF AXIAL EJECTION DURING EXCITATION WITH A CAPACITIVELY COUPLED OPEN TRAPPED-ION CELL FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :177-180
[3]  
Bier M. E., 1995, U. S. Patent, Patent No. [5,420,425 A, 5420425]
[4]   MULTIPLE-SHELL STRUCTURES OF LASER-COOLED MG-24(+) IONS IN A QUADRUPOLE STORAGE RING [J].
BIRKL, G ;
KASSNER, S ;
WALTHER, H .
NATURE, 1992, 357 (6376) :310-313
[5]  
Campbell JM, 1998, RAPID COMMUN MASS SP, V12, P1463, DOI 10.1002/(SICI)1097-0231(19981030)12:20<1463::AID-RCM357>3.3.CO
[6]  
2-8
[7]   An interface with a linear quadrupole ion guide for an electrospray-ion trap mass spectrometer system [J].
Cha, BC ;
Blades, M ;
Douglas, DJ .
ANALYTICAL CHEMISTRY, 2000, 72 (22) :5647-5654
[8]   A combined linear ion trap time-of-flight system with improved performance and MSn capabilities [J].
Collings, BA ;
Campbell, JM ;
Mao, DM ;
Douglas, DJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (19) :1777-1795
[9]   ION-TRAPPING TECHNIQUE FOR ION MOLECULE REACTION STUDIES IN THE CENTER QUADRUPOLE OF A TRIPLE QUADRUPOLE MASS-SPECTROMETER [J].
DOLNIKOWSKI, GG ;
KRISTO, MJ ;
ENKE, CG ;
WATSON, JT .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1988, 82 (1-2) :1-15
[10]  
DOUGLAS DJ, 1991, Patent No. 5179278