Three-way alternating least squares using three-dimensional tensors in MATLAB®

被引:22
作者
Bezemer, E [1 ]
Rutan, SC [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Chem, Richmond, VA 23284 USA
关键词
multivariate curve resolution; alternating least squares; two-way data analysis; three-way data analysis; kinetics; trilinearity; closure;
D O I
10.1016/S0169-7439(01)00199-X
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper describes an improved three-way alternating least-squares multivariate curve resolution algorithm that makes use of the recently introduced multi-dimensional arrays of MATLAB((R)). Multi-dimensional arrays allow for a convenient way to apply chemically sound constraints, such as closure, in the third dimension. The program is designed for kinetic studies on liquid chromatography with diode array detection but can be used for other three-way data analysis. The program is tested with a large number of synthetic data sets and its flexibility is demonstrated, especially when non-trilinear data sets are fit. In this case, the algorithm finds a solution with a better fit than direct trilinear decomposition (DTD). When trilinear data are used, the optimal fit is not as good as when a direct decomposition method is used. Most real data sets, however, have some degree of non-trilinearity. This makes this method a better choice to analyze non-trilinear, three-way data than direct trilinear decomposition. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:239 / 251
页数:13
相关论文
共 31 条
[1]  
[Anonymous], 1990, Journal ofChemometrics, DOI DOI 10.1002/CEM.1180040105
[2]   ASSESSING CHROMATOGRAPHIC PEAK PURITY USING CONDITION INDEX AND SINGULAR-VALUE EVOLVING PROFILES [J].
BAKKEN, GA ;
KALIVAS, JH .
ANALYTICA CHIMICA ACTA, 1995, 300 (1-3) :173-181
[3]  
BLYTH TS, 1986, MATRICES VECTOR SPAC
[4]   EXTENSION OF TRILINEAR DECOMPOSITION METHOD WITH AN APPLICATION TO THE FLOW PROBE SENSOR [J].
BOOKSH, KS ;
LIN, ZH ;
WANG, ZY ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :2561-2569
[5]  
Bro R, 1999, J CHEMOMETR, V13, P295, DOI 10.1002/(SICI)1099-128X(199905/08)13:3/4<295::AID-CEM547>3.0.CO
[6]  
2-Y
[7]  
Bro R, 1996, J CHEMOMETR, V10, P47, DOI 10.1002/(SICI)1099-128X(199601)10:1<47::AID-CEM400>3.3.CO
[8]  
2-3
[9]   FLUORESCENCE DETECTION IN LIQUID-CHROMATOGRAPHY WITH AN INTENSIFIED DIODE-ARRAY DETECTOR [J].
CECIL, TL ;
RUTAN, SC .
JOURNAL OF CHROMATOGRAPHY, 1991, 556 (1-2) :495-503
[10]   Purity assessment and resolution of tetracycline hydrochloride samples analysed using high-performance liquid chromatography with diode array detection [J].
De Braekeleer, K ;
de Juan, A ;
Massart, DL .
JOURNAL OF CHROMATOGRAPHY A, 1999, 832 (1-2) :67-86