Double-heater-wire circuits and heat-and-moisture exchangers and the risk of ventilator-associated pneumonia

被引:71
作者
Boots, RJ [1 ]
George, N
Faoagali, JL
Druery, J
Dean, K
Heller, RF
机构
[1] Royal Brisbane & Womens Hosp, Dept Intens Care Med, Brisbane, Qld, Australia
[2] Royal Brisbane & Womens Hosp, Dept Microbiol, Brisbane, Qld, Australia
关键词
humidification; ventilator-associated pneumonia; heat-and-moisture exchanger; airway resistance; randomized trial;
D O I
10.1097/01.CCM.0000201887.51076.31
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To compare the incidence of ventilator-associated pneumonia (VAP) in patients ventilated in intensive care by means of circuits humidified with a hygroscopic heat-and-moisture exchanger with a bacterial viral filter (HME) or hot-water humidification with a heater wire in both inspiratory and expiratory circuit limbs (DHW) or the inspiratory limb only (SHW). Design: A prospective, randomized trial. Setting: A metropolitan teaching hospital's general intensive care unit. Patients: Three hundred eighty-one patients requiring a minimum period of mechanical ventilation of 48 hrs. Interventions: Patients were randomized to humidification with use of an HME (n = 190), SHW (n = 94), or DHW (n = 97). Measurements and Main Results. Study end points were VAP diagnosed on the basis of Clinical Pulmonary Infection Score (CPIS) (1), HME resistance after 24 hrs of use, endotracheal tube resistance, and HME use per patient. VAP occurred with similar frequency in all groups (13%, HME; 14%, DHW; 10%, SHW; p = 0.61) and was predicted only by current smoking (adjusted odds ratio [AOR], 2.1; 95% confidence interval [CI], 1.1-3.9; p =.03) and ventilation days (AOR, 1.05; 95% Cl, 1.0-1.2; p =.001); VAP was less likely for patients with an admission diagnosis of pneumonia (AOR, 0.40; 95% Cl, 0.4-0.2; p =.04). HME resistance after 24 hrs of use measured at a gas flow of 50 L/min was 0.9 cm H2O (0.4-2.9). Endotracheal tube resistance was similar for all three groups (16-19 cm H2O min/L; p =.2), as were suction frequency, secretion thickness, and blood on suctioning (p =.32, p =.06, and p =.34, respectively). The HME use per patient per day was 1.13. Conclusions: Humidification technique does not influence either VAP incidence or secretion characteristics, but HMEs may have air-flow resistance higher than manufacturer specifications after 24 hrs of use.
引用
收藏
页码:687 / 693
页数:7
相关论文
共 41 条
[1]   REPORT OF THE AMERICAN-EUROPEAN CONSENSUS CONFERENCE ON ACUTE RESPIRATORY-DISTRESS SYNDROME - DEFINITIONS, MECHANISMS, RELEVANT OUTCOMES, AND CLINICAL-TRIAL COORDINATION [J].
BERNARD, GR ;
ARTIGAS, A ;
BRIGHAM, KL ;
CARLET, J ;
FALKE, K ;
HUDSON, L ;
LAMY, M ;
LEGALL, JR ;
MORRIS, A ;
SPRAGG, R ;
Cochin, B ;
Lanken, PN ;
Leeper, KV ;
Marini, J ;
Murray, JF ;
Oppenheimer, L ;
Pesenti, A ;
Reid, L ;
Rinaldo, J ;
Villar, J ;
van Asbeck, BS ;
Dhainaut, JF ;
Mancebo, J ;
Matthay, M ;
Meyrick, B ;
Payen, D ;
Perret, C ;
Fowler, AA ;
Schaller, MD ;
Hudson, LD ;
Hyers, T ;
Knaus, W ;
Matthay, R ;
Pinsky, M ;
Bone, RC ;
Bosken, C ;
Johanson, WG ;
Lewandowski, K ;
Repine, J ;
Rodriguez-Roisin, R ;
Roussos, C ;
Antonelli, MA ;
Beloucif, S ;
Bihari, D ;
Burchardi, H ;
LeMaire, F ;
Montravers, P ;
Petty, TL ;
Robotham, J ;
Zapol, W .
JOURNAL OF CRITICAL CARE, 1994, 9 (01) :72-81
[2]   THE EFFECTS OF VASODILATION WITH PROSTACYCLIN ON OXYGEN DELIVERY AND UPTAKE IN CRITICALLY ILL PATIENTS [J].
BIHARI, D ;
SMITHIES, M ;
GIMSON, A ;
TINKER, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1987, 317 (07) :397-403
[3]   Changing a hydrophobic heat and moisture exchanger after 48 hours rather than 24 hours: a clinical and microbiological evaluation [J].
Boisson, C ;
Viviand, X ;
Arnaud, S ;
Thomachot, L ;
Miliani, Y ;
Martin, C .
INTENSIVE CARE MEDICINE, 1999, 25 (11) :1237-1243
[4]   BRONCHIOLITIS OBLITERANS ORGANIZING PNEUMONIA - A CLINICAL AND RADIOLOGICAL REVIEW [J].
BOOTS, RJ ;
MCEVOY, JDS ;
MOWAT, P ;
LEFEVRE, I .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1995, 25 (02) :140-145
[5]   Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients [J].
Boots, RJ ;
Howe, S ;
George, N ;
Harris, FM ;
Faoagali, J .
CRITICAL CARE MEDICINE, 1997, 25 (10) :1707-1712
[6]  
Campbell R S, 2000, Respir Care, V45, P306
[7]  
CELLI BR, 1995, AM J RESP CRIT CARE, V152, pS77
[8]   USE OF HEAT AND MOISTURE EXCHANGING (HME) FILTERS IN MECHANICALLY VENTILATED ICU PATIENTS - INFLUENCE ON AIRWAY FLOW-RESISTANCE [J].
CHIARANDA, M ;
VERONA, L ;
PINAMONTI, O ;
DOMINIONI, L ;
MINOJA, G ;
CONTI, G .
INTENSIVE CARE MEDICINE, 1993, 19 (08) :462-466
[9]   ENDOTRACHEAL-TUBE OCCLUSION ASSOCIATED WITH THE USE OF HEAT AND MOISTURE EXCHANGERS IN THE INTENSIVE-CARE UNIT [J].
COHEN, IL ;
WEINBERG, PF ;
FEIN, IA ;
ROWINSKI, GS .
CRITICAL CARE MEDICINE, 1988, 16 (03) :277-279
[10]   EFFECTS OF THE HEAT-MOISTURE EXCHANGERS ON DYNAMIC HYPERINFLATION OF MECHANICALLY VENTILATED COPD PATIENTS [J].
CONTI, G ;
DEBLASI, RA ;
ROCCO, M ;
PELAIA, P ;
ANTONELLI, M ;
BUFI, M ;
MATTIA, C ;
GASPARETTO, A .
INTENSIVE CARE MEDICINE, 1990, 16 (07) :441-443