RF safety of wires in interventional MRI: Using a safety index

被引:159
作者
Yeung, CJ
Susil, RC
Atalar, E
机构
[1] Johns Hopkins Univ, Johns Hopkins Outpatient Ctr, Sch Med, Dept Biomed Engn, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
关键词
MRI safety; RF heating; interventional MRI; moment method; metallic implants;
D O I
10.1002/mrm.10037
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
With the rapid growth of interventional MRI, radiofrequency (RF) heating at the tips of guidewires, catheters, and other wire-shaped devices has become an important safety issue. Previous studies have identified some of the variables that affect the relative magnitude of this heating but none could predict the absolute amount of heating to formulate safety margins. This study presents the first theoretical model of wire tip heating that can accurately predict its absolute value, assuming a straight wire, a homogeneous RF coil, and a wire that does not extend out of the tissue. The local specific absorption rate (SAR) amplification from induced currents on insulated and bare wires was calculated using the method of moments. This SAR gain was combined with a semianalytic solution to the bioheat transfer equation to generate a safety index. The safety index (degreesC/(W/kg)) is a measure of the in vivo temperature change that can occur with the wire in place, normalized to the SAR of the pulse sequence. This index can be used to set limits on the spatial peak SAR of pulse sequences that are used with the interventional wire. For the case of a straight resonant wire in a tissue with very low perfusion, only about 100 mW/kg/degreesC spatial peak SAR may be used at 1.5 T. But for less than or equal to 10-cm wires with an insulation thickness greater than or equal to 30% of the wire radius that are placed in well-perfused tissues, normal operating conditions of 4 W/kg spatial peak SAR are possible at 1.5 T. Further model development to include the influence of inhomogeneous RF, curved wires, and wires that extend out of the sample are required to generate safety indices that are applicable to common clinical situations. We propose a simple way to ensure safety when using an interventional wire: set a limit on the SAR of allowable pulse sequences that is a factor of a safety index below the tolerable temperature increase. Magn Reson Med 47:187-193, 2002. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 24 条
[1]   Effects of magnetic resonance Imaging on cardiac pacemakers and electrodes [J].
Achenbach, S ;
Moshage, W ;
Diem, B ;
Bieberle, T ;
Schibgilla, V ;
Bachmann, K .
AMERICAN HEART JOURNAL, 1997, 134 (03) :467-473
[2]  
ATALAR E, 1999, P ISMRM 7 SCI M EXH, P1006
[3]   A galerkin moment method for the analysis of an insulated antenna in a dissipative dielectric medium [J].
Atlamazoglou, PE ;
Uzunoglu, NK .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1998, 46 (07) :988-996
[4]   Calculation of electric fields induced near metal implants by magnetic resonance imaging switched-gradient magnetic fields [J].
Buechler, DN ;
Durney, CH ;
Christensen, DA .
MAGNETIC RESONANCE IMAGING, 1997, 15 (10) :1157-1166
[5]   RF heating of implanted spinal fusion stimulator during magnetic resonance imaging [J].
Chou, CK ;
McDougall, JA ;
Chan, KW .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (05) :367-373
[6]   THERAPEUTIC APPLICATIONS OF ELECTROMAGNETIC POWER [J].
GUY, AW ;
LEHMANN, JF ;
STONEBRIDGE, JB .
PROCEEDINGS OF THE IEEE, 1974, 62 (01) :55-75
[7]  
Harrington R. F., 1968, FIELD COMPUTATION MO
[8]  
International Electrotechnical Commission, 1995, 60601233 IEC
[9]  
Konings MK, 2000, J MAGN RESON IMAGING, V12, P79, DOI 10.1002/1522-2586(200007)12:1<79::AID-JMRI9>3.3.CO
[10]  
2-K