Epidermal Differential Impedance Sensor for Conformal Skin Hydration Monitoring

被引:122
作者
Huang, Xian [1 ]
Yeo, Woon-Hong [1 ]
Liu, Yuhao [1 ]
Rogers, John A. [1 ]
机构
[1] Univ Illinois, Dept Mat Sci & Engn, Frederick Seitz Mat Res Lab, Urbana, IL 61801 USA
关键词
STRATUM-CORNEUM; ELECTRICAL-PROPERTIES; DIELECTRIC-PROPERTIES; IN-VIVO; INTERFERENCE; FRICTION; INVIVO; TISSUE;
D O I
10.1007/s13758-012-0052-8
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We present the design and use of an ultrathin, stretchable sensor system capable of conformal lamination onto the skin, for precision measurement and spatial mapping of levels of hydration. This device, which we refer to as a class of 'epidermal electronics' due to its 'skin-like' construction and mode of intimate integration with the body, contains miniaturized arrays of impedance-measurement electrodes arranged in a differential configuration to compensate for common-mode disturbances. Experimental results obtained with different frequencies and sensor geometries demonstrate excellent precision and accuracy, as benchmarked against conventional, commercial devices. The reversible, non-invasive soft contact of this device with the skin makes its operation appealing for applications ranging from skin care, to athletic monitoring to health/wellness assessment.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 39 条
[1]   Measurement of hydration in the stratum corneum with the MoistureMeter and comparison with the Corneometer [J].
Alanen, E ;
Nuutinen, J ;
Nicklén, K ;
Lahtinen, T ;
Mönkkönen, J .
SKIN RESEARCH AND TECHNOLOGY, 2004, 10 (01) :32-37
[2]   Millimeter wave reflectivity used for measurement of skin hydration with different moisturizers [J].
Alekseev, S. I. ;
Szabo, I. ;
Ziskin, M. C. .
SKIN RESEARCH AND TECHNOLOGY, 2008, 14 (04) :390-396
[3]   Near-IR spectroscopic imaging for skin hydration: The long and the short of it [J].
Attas, EM ;
Sowa, MG ;
Posthumus, TB ;
Schattka, BJ ;
Mantsch, HH ;
Zhang, SLL .
BIOPOLYMERS, 2002, 67 (02) :96-106
[4]  
Barel A O, 1997, Skin Res Technol, V3, P107, DOI 10.1111/j.1600-0846.1997.tb00171.x
[5]   HYDRATION STUDIES ON SCALY HAND ECZEMA [J].
BLICHMANN, C ;
SERUP, J .
CONTACT DERMATITIS, 1987, 16 (03) :155-159
[6]   A multidisciplinary approach to evaluation and treatment of atopic dermatitis [J].
Boguniewicz, Mark ;
Nicol, Noreen ;
Kelsay, Kim ;
Leung, Donald Y. M. .
SEMINARS IN CUTANEOUS MEDICINE AND SURGERY, 2008, 27 (02) :115-127
[7]  
Choi JW, 2012, SKIN RES TECHNOL, V0, P1
[8]  
Clarys P., 1999, Skin Research and Technology, V5, P14, DOI DOI 10.1111/j.1600-0846.1999.tb00198.x
[9]   Use of Cutometer to assess epidermal hydration [J].
Dobrev, H .
SKIN RESEARCH AND TECHNOLOGY, 2000, 6 (04) :239-244
[10]   Comparative study of five instruments measuring stratum corneurn hydration (Comeometer CM 820 and CM 825, Skicon 200, Nova DPM 9003, DermaLab). Part I. In vitro [J].
Fluhr, Joachim W. ;
Gloor, Max ;
Lazzerini, Sabrina ;
Kleesz, Peter ;
Grieshaber, Romano ;
Berardesca, Enzo .
SKIN RESEARCH AND TECHNOLOGY, 1999, 5 (03) :161-170