Determination of hydrogen peroxide by utilizing a cobalt(II)hexacyanoferrate-modified glassy carbon electrode as a chemical sensor

被引:80
作者
Lin, MS
Jan, BI
机构
[1] Department of Chemistry, Tamkang University, Tamsui
关键词
electrochemical sensor; hydrogen peroxide; cobalt(II)hexacyanoferrate; mixed-valence cluster; rotating ring-disk electrode;
D O I
10.1002/elan.1140090416
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A mixed-valence cluster of cobalt(II)hexacyanoferrate possesses an elect-on transfer property and is suitable for the development of an effective hydrogen peroxide detection scheme. The characteristics of cobalt(II)hexacyanoferrate have been studied using both elemental analysis and infrared spectra, confirming the structure is Co-2(II)[Fe-II(CN)(6)]. The cobalt(II)hexacyanoferrate-modified electrode exhibits a rapid response (t(95%) = 6.5 s) to the injection of 5.0 x 10(-5)M hydrogen peroxide. The linearity of the response is up to 1.1 x 10(-3)M (correlation coefficients is 0.999). The sensitivity of this modified electrode is 11.8 mu A/mM-mm(2). The detection limit of cobalt(II)hexacyanoferrate-modified electrode to hydrogen peroxide is 6.25 x 10(-8)M. The current chemical sensor modified with Co-2(II)[Fe-6(II)] has better sensitivity than previous odes. The modified glassy carbon electrode shows no interference from ascorbic acid, uric acid, acetaminophen, 1,4-dihydroxyquinone, dopamine at the 2.0 x 10(-4)M level and polyamines at 5.0 x 10(-5)M level.
引用
收藏
页码:340 / 344
页数:5
相关论文
共 25 条
[1]   FIBER-OPTIC SENSOR FOR THE DETERMINATION OF GLUCOSE USING MICELLAR ENHANCED CHEMI-LUMINESCENCE OF THE PEROXYOXALATE REACTION [J].
ABDELLATIF, MS ;
GUILBAULT, GG .
ANALYTICAL CHEMISTRY, 1988, 60 (24) :2671-2674
[2]  
Brown D.M., 1980, Mixed Valence Compounds
[3]   FLOW-THROUGH OPTICAL BIOSENSOR BASED ON THE PERMANENT IMMOBILIZATION OF AN ENZYME AND TRANSIENT RETENTION OF A REACTION-PRODUCT [J].
FERNANDEZROMERO, JM ;
DECASTRO, MDL .
ANALYTICAL CHEMISTRY, 1993, 65 (21) :3048-3052
[4]  
GHOSH SN, 1974, J INORG NUCL CHEM, V36, P2465, DOI 10.1016/0022-1902(74)80454-9
[5]   FLUOROMETRIC-DETERMINATION OF HYDROGEN-PEROXIDE IN GROUNDWATER [J].
HOLM, TR ;
GEORGE, GK ;
BARCELONA, MJ .
ANALYTICAL CHEMISTRY, 1987, 59 (04) :582-586
[6]   IMMOBILIZED LUMINOL CHEMI-LUMINESCENCE REAGENT SYSTEM FOR HYDROGEN-PEROXIDE DETERMINATIONS IN FLOWING STREAMS [J].
HOOL, K ;
NIEMAN, TA .
ANALYTICAL CHEMISTRY, 1988, 60 (09) :834-837
[7]   CHEMILUMINESCENCE ANALYSIS IN FLOWING STREAMS WITH LUMINOL IMMOBILIZED ON SILICA AND CONTROLLED-PORE GLASS [J].
HOOL, K ;
NIEMAN, TA .
ANALYTICAL CHEMISTRY, 1987, 59 (06) :869-872
[8]   EXPLOITATION OF REVERSED MICELLES AS A MEDIUM IN ANALYTICAL CHEMILUMINESCENCE MEASUREMENTS WITH APPLICATION TO THE DETERMINATION OF HYDROGEN-PEROXIDE USING LUMINOL [J].
HOSHINO, H ;
HINZE, WL .
ANALYTICAL CHEMISTRY, 1987, 59 (03) :496-504
[9]   NONENZYMATIC METHOD FOR THE DETERMINATION OF HYDROGEN-PEROXIDE IN ATMOSPHERIC SAMPLES [J].
LEE, JH ;
TANG, IN ;
WEINSTEINLLOYD, JB .
ANALYTICAL CHEMISTRY, 1990, 62 (21) :2381-2384
[10]   PINEAPPLE-TISSUE BASED BIOELECTRODE FOR THE DETERMINATION OF HYDROGEN-PEROXIDE [J].
LIN, MS ;
THAM, SY ;
RECHNITZ, GA .
ELECTROANALYSIS, 1990, 2 (07) :511-516