[C-13]octanoic acid breath test for gastric emptying of solids: Accuracy, reproducibility, and comparison with scintigraphy

被引:173
作者
Choi, MG
Camilleri, M
Burton, DD
Zinsmeister, AR
Forstrom, LA
Nair, KS
机构
[1] MAYO CLIN & MAYO FDN,GASTROENTEROL RES UNIT,ROCHESTER,MN 55905
[2] MAYO CLIN & MAYO FDN,BIOSTAT SECT,ROCHESTER,MN 55905
[3] MAYO CLIN & MAYO FDN,NUCL MED SECT,ROCHESTER,MN 55905
[4] MAYO CLIN & MAYO FDN,MASS SPECTROMETRY CORE LAB,ROCHESTER,MN 55905
关键词
D O I
10.1016/S0016-5085(97)70126-4
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background & Aims: Previous work suggested that a breath test using C-13 accurately measures gastric emptying of solids. Thus, breath test half emptying time (t(1/2)) minus 66 minutes was claimed to estimate accurately t(1/2) by scintigraphy. The aim of this study was to evaluate the accuracy and reproducibility of this breath test in healthy subjects. Methods: Fifteen volunteers (8 men and 7 women; mean age, 41 +/- 13 years) underwent simultaneous scintigraphy and [C-13]octanoic acid breath test. Scans and breath samples were obtained every 15 minutes for 4 and 6 hours, respectively. The breath test was repeated three times within a 3-week period. Results: Parameters from scintigraphy and breath test were not correlated significantly. Differences of lag phase and t(1/2) between the two tests were highly variable (range for t(1/2), -33.1 to 169.6; mean, 48.0 minutes). Increasing breath test ''duration'' (samples over 4, 5, or 6 hours) yielded decreasing estimates of the lag phase and t(1/2) Although widely different values were observed in some subjects, repeated breath tests showed a high degree of reproducibility within individuals (mean coefficient of variation, 12%). Conclusion: [C-13]Octanoic acid breath test for gastric emptying of solids requires further validation before it can substitute for scintigraphy as a diagnostic test, but it seems useful for intraindividual comparisons.
引用
收藏
页码:1155 / 1162
页数:8
相关论文
共 35 条
[1]   APPLIED POTENTIAL TOMOGRAPHY - A NEW NONINVASIVE TECHNIQUE FOR MEASURING GASTRIC-EMPTYING [J].
AVILL, R ;
MANGNALL, YF ;
BIRD, NC ;
BROWN, BH ;
BARBER, DC ;
SEAGAR, AD ;
JOHNSON, AG ;
READ, NW .
GASTROENTEROLOGY, 1987, 92 (04) :1019-1026
[2]   Mass spectrometric methods for determination of [C-13] leucine enrichment in human muscle protein [J].
Balagopal, P ;
Ford, GC ;
Ebenstein, DB ;
Nadeau, DA ;
Nair, KS .
ANALYTICAL BIOCHEMISTRY, 1996, 239 (01) :77-85
[3]  
BJORKMAN DJ, 1991, AM J GASTROENTEROL, V86, P821
[4]   THE [C-13]ACETATE BREATH TEST ACCURATELY REFLECTS GASTRIC-EMPTYING OF LIQUIDS IN BOTH LIQUID AND SEMISOLID TEST MEALS [J].
BRADEN, B ;
ADAMS, S ;
DUAN, LP ;
ORTH, KH ;
MAUL, FD ;
LEMBCKE, B ;
HOR, G ;
CASPARY, WF .
GASTROENTEROLOGY, 1995, 108 (04) :1048-1055
[5]   VARIABILITY OF GASTRIC-EMPTYING MEASUREMENTS IN MAN EMPLOYING STANDARDIZED RADIOLABELED MEALS [J].
BROPHY, CM ;
MOORE, JG ;
CHRISTIAN, PE ;
EGGER, MJ ;
TAYLOR, AT .
DIGESTIVE DISEASES AND SCIENCES, 1986, 31 (08) :799-806
[6]   TOWARDS A LESS COSTLY BUT ACCURATE TEST OF GASTRIC-EMPTYING AND SMALL-BOWEL TRANSIT [J].
CAMILLERI, M ;
ZINSMEISTER, AR ;
GREYDANUS, MP ;
BROWN, ML ;
PROANO, M .
DIGESTIVE DISEASES AND SCIENCES, 1991, 36 (05) :609-615
[7]   HUMAN GASTRIC-EMPTYING AND COLONIC FILLING OF SOLIDS CHARACTERIZED BY A NEW METHOD [J].
CAMILLERI, M ;
COLEMONT, LJ ;
PHILLIPS, SF ;
BROWN, ML ;
THOMFORDE, GM ;
CHAPMAN, N ;
ZINSMEISTER, AR .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (02) :G284-G290
[8]   GASTRIC-EMPTYING IN NORMAL SUBJECTS - A REPRODUCIBLE TECHNIQUE USING A SINGLE SCINTILLATION CAMERA AND COMPUTER-SYSTEM [J].
COLLINS, PJ ;
HOROWITZ, M ;
COOK, DJ ;
HARDING, PE ;
SHEARMAN, DJC .
GUT, 1983, 24 (12) :1117-1125
[9]  
CORTOT A, 1981, GASTROENTEROLOGY, V80, P922
[10]   Variability of gastrointestinal transit in healthy women and men [J].
Degen, LP ;
Phillips, SF .
GUT, 1996, 39 (02) :299-305