Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump

被引:133
作者
Zhang, JT
Gellman, B
Koert, A
Dasse, KA
Gilbert, RJ
Griffith, BP
Wu, ZJJ
机构
[1] Univ Maryland, Sch Med, Dept Surg, Artificial Organs Lab, Baltimore, MD 21201 USA
[2] Levitronix LLC, Waltham, MA USA
[3] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
关键词
computational fluid dynamics; hemolysis modeling; magnetically levitated rotor; CentriMag blood pump; ventricular assist device;
D O I
10.1111/j.1525-1594.2006.00203.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The CentriMag centrifugal blood pump is a newly developed ventricular assist device based on magnetically levitated bearingless rotor technology. A combined computational and experimental study was conducted to characterize the hemodynamic and hemocompatibility performances of this novel blood pump. Both the three-dimensional flow features of the CentriMag blood pump and its hemolytic characteristics were analyzed using computational fluid dynamics (CFD)-based modeling. The hydraulic pump performance and hemolysis level were quantified experimentally. The CFD simulation demonstrated a clean and streamlined flow field in the main components of the CentriMag blood pump. The predicted results by hemolysis model indicated no significant high shear stress regions in the pump. A comparison of CFD predictions and experimental results showed good agreements. The relatively large gap passages (1.5 mm) between the outer rotor walls and the lower housing cavity walls provide a very good surface washing through a secondary flow path while the shear stresses in the secondary flow paths are reduced, resulting in a low rate of hemolysis ([Normalized Index of Hemolysis] NIH = 0.0029 +/- 0.006) without a decrease of the pump's hydrodynamic performance (pressure head: 352 mm Hg at a flow rate of 5.0 L/min and a rotational speed of 4000 rpm).
引用
收藏
页码:168 / 177
页数:10
相关论文
共 16 条
[11]   A method of isolating surface tension and yield stress effects in a U-shaped scanning capillary-tube viscometer using a Casson model [J].
Kim, S ;
Cho, YI ;
Hogenauer, WN ;
Kensey, KR .
JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2002, 103 (2-3) :205-219
[12]  
Malinauskas RA, 1997, ARTIF ORGANS, V21, P1255
[13]   The CentriMag: A new optimized centrifugal blood pump with levitating impeller [J].
Mueller, JP ;
Kuenzli, A ;
Reuthebuch, O ;
Dasse, K ;
Kent, S ;
Zuend, G ;
Turina, MI ;
Lachat, ML .
HEART SURGERY FORUM, 2004, 7 (05) :E477-E480
[14]  
RADOVANCEVIC B, 2003, 49 ANN C AM SOC ART, P19
[15]  
Schob R., 2002, WORLD PUMPS JUL, P34
[16]   Fluid dynamic characterization of operating conditions for continuous flow blood pumps [J].
Wu, ZJJ ;
Antaki, JF ;
Burgreen, GW ;
Butler, KC ;
Thomas, DC ;
Griffith, BP .
ASAIO JOURNAL, 1999, 45 (05) :442-449