Scanometric potassium determination with ionophore-based disposable sensors

被引:30
作者
Lapresta-Fernandez, A. [1 ]
Capitan-Vallvey, L. F. [1 ]
机构
[1] Univ Granada, Fac Sci, Solid Phase Spectrometry Res Grp, Dept Analyt Chem, E-18071 Granada, Spain
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2008年 / 134卷 / 02期
关键词
Scanner; Potassium determination; Disposable sensor; Digital image; Image color analysis; Color management;
D O I
10.1016/j.snb.2008.06.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A conventional flatbed scanner is used to acquire the analytical parameters for quantitative determination in one-shot optical sensors based on ionophore-chromoionophore chemistry. Variables affecting the acquisition of the images and treatment were studied. The analytical parameter, an estimated reflection density, is obtained from an area of the sensing zone of the disposable sensor using the average luminosity of the best channel that fits the sensor theoretical model. The fit of the experimental results to the theoretical sigmoidal model and the precision of the results, in terms of relative standard deviation (R.S.D.%), are used to optimize the scanner variables. In order to improve the reliability and validity of the results we worked with scanner color management. Applying this methodology, we tried to make color measurements as independent as possible from the particular scanner used. Furthermore, the perceptual stimulus, that is, the color sensor response, is preserved and enhanced across this imaging treatment without any loss of information. Using this scanner protocol for measurement and the relation between digital output of the color scanner and the concentration of potassium into the sensing zone it is possible to analyze potassium between 6.58 x 10(-6) and 10(-2) M with a precision, expressed as R.S.D. of loga(K)., ranging from 0.45 to 1.80%. These results are good when compared to the same procedure using a DAD spectrophotometer in which the concentration range is 1.31 x 10(-1) and 0.1 M and the precision range between 3.31 and 7.66%. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:694 / 701
页数:8
相关论文
共 48 条
[1]   Speciation of iron(II), iron(III) and full-range pH monitoring using paptode: A simple colorimetric method as an appropriate alternative for optodes [J].
Abbaspour, A ;
Mehrgardi, MA ;
Noori, A ;
Kamyabi, MA ;
Khalafi-Nezhad, A ;
Rad, MNS .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (02) :857-865
[2]   Power law olivine crystal size distributions in lithospheric mantle xenoliths [J].
Armienti, P ;
Tarquini, S .
LITHOS, 2002, 65 (3-4) :273-285
[3]   Signal-to-noise ratios of 6 intraoral digital sensors [J].
Attaelmanan, AG ;
Borg, E ;
Gröndahl, HG .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2001, 91 (05) :611-615
[4]   Quantification of soil features using digital image processing (DIP) techniques [J].
Aydemir, S ;
Keskin, S ;
Drees, LR .
GEODERMA, 2004, 119 (1-2) :1-8
[5]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[6]   Protein determination by ponceau S using digital color image analysis of protein spots on nitrocellulose membranes [J].
Bannur, SV ;
Kulgod, SV ;
Metkar, SS ;
Mahajan, SK ;
Sainis, JK .
ANALYTICAL BIOCHEMISTRY, 1999, 267 (02) :382-389
[7]   Example of use of a desktop scanner for data acquisition in a colorimetric assay [J].
Birch, NC ;
Stickle, DF .
CLINICA CHIMICA ACTA, 2003, 333 (01) :95-96
[8]  
Blazsek M, 2004, CHEM LISTY, V98, P989
[9]  
*CAN INC, 2007, IM QUAL IMPR TECHN
[10]  
Capitan-Vallvey L.F., 2005, ENCY SENSORS, P55