摘要
A conventional flatbed scanner is used to acquire the analytical parameters for quantitative determination in one-shot optical sensors based on ionophore-chromoionophore chemistry. Variables affecting the acquisition of the images and treatment were studied. The analytical parameter, an estimated reflection density, is obtained from an area of the sensing zone of the disposable sensor using the average luminosity of the best channel that fits the sensor theoretical model. The fit of the experimental results to the theoretical sigmoidal model and the precision of the results, in terms of relative standard deviation (R.S.D.%), are used to optimize the scanner variables. In order to improve the reliability and validity of the results we worked with scanner color management. Applying this methodology, we tried to make color measurements as independent as possible from the particular scanner used. Furthermore, the perceptual stimulus, that is, the color sensor response, is preserved and enhanced across this imaging treatment without any loss of information. Using this scanner protocol for measurement and the relation between digital output of the color scanner and the concentration of potassium into the sensing zone it is possible to analyze potassium between 6.58 x 10(-6) and 10(-2) M with a precision, expressed as R.S.D. of loga(K)., ranging from 0.45 to 1.80%. These results are good when compared to the same procedure using a DAD spectrophotometer in which the concentration range is 1.31 x 10(-1) and 0.1 M and the precision range between 3.31 and 7.66%. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:694 / 701
页数:8
相关论文
共 48 条
[11]   A disposable single-use optical sensor for potassium determination based on neutral ionophore [J].
Capitán-Vallvey, LF ;
Ramos, MDF ;
Al-Natsheh, M .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 88 (02) :217-222
[12]   Variation in thermally induced melanism in monarch butterflies (Lepidoptera:Nymphalidae) from three North American populations [J].
Davis, AK ;
Farrey, BD ;
Altizer, S .
JOURNAL OF THERMAL BIOLOGY, 2005, 30 (05) :410-421
[13]  
FERNANDEZ R, 2007, RETOQUE DIGITAL AJUS
[14]   Illuminant and device invariant colour using histogram equalisation [J].
Finlayson, G ;
Hordley, S ;
Schaefer, G ;
Tian, GY .
PATTERN RECOGNITION, 2005, 38 (02) :179-190
[15]   Microplate-based microbial assay for risk assessment and (eco)toxic fingerprinting of chemicals [J].
Gabrielson, J ;
Kühn, I ;
Colque-Navarro, P ;
Hart, M ;
Iversen, A ;
McKenzie, D ;
Möllby, R .
ANALYTICA CHIMICA ACTA, 2003, 485 (01) :121-130
[16]   Development of multianalyte sensor arrays composed of chemically derivatized polymeric microspheres localized in micromachined cavities [J].
Goodey, A ;
Lavigne, JJ ;
Savoy, SM ;
Rodriguez, MD ;
Curey, T ;
Tsao, A ;
Simmons, G ;
Wright, J ;
Yoo, SJ ;
Sohn, Y ;
Anslyn, EV ;
Shear, JB ;
Neikirk, DP ;
McDevitt, JT .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (11) :2559-2570
[17]  
Greyson J, 1981, J Automat Chem, V3, P66, DOI 10.1155/S1463924681000199
[18]   Developments in the use of image analysis for the assessment of oriental noodle appearance and colour [J].
Hatcher, DW ;
Symons, SJ ;
Manivannan, U .
JOURNAL OF FOOD ENGINEERING, 2004, 61 (01) :109-117
[19]  
HUERTAS R, 2004, ARG 2004 P, P45
[20]   Colorimetric sensor Arrays for volatile organic compounds [J].
Janzen, Michael C. ;
Ponder, Jennifer B. ;
Bailey, Daniel P. ;
Ingison, Crystal K. ;
Suslick, Kenneth S. .
ANALYTICAL CHEMISTRY, 2006, 78 (11) :3591-3600