Development of multianalyte sensor arrays composed of chemically derivatized polymeric microspheres localized in micromachined cavities

被引:159
作者
Goodey, A
Lavigne, JJ
Savoy, SM
Rodriguez, MD
Curey, T
Tsao, A
Simmons, G
Wright, J
Yoo, SJ
Sohn, Y
Anslyn, EV
Shear, JB
Neikirk, DP
McDevitt, JT [1 ]
机构
[1] Univ Texas, Dept Elect & Comp Engn, Austin, TX 78712 USA
[2] Univ Texas, Dept Chem & Biochem, Austin, TX 78712 USA
[3] Univ Texas, Inst Mol & Cellular Biol, Austin, TX 78712 USA
[4] Univ Texas, Ctr Nanostructured Mat, Austin, TX 78712 USA
[5] Univ Texas, Texas Mat Inst, Austin, TX 78712 USA
关键词
D O I
10.1021/ja003341l
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The development of a chip-based sensor array composed of individually addressable polystyrene-poly(ethylene glycol) and agarose microspheres has been demonstrated. The microspheres are selectively arranged in micromachined cavities localized on silicon wafers. These cavities are created with an anisotropic etch and serve as miniaturized reaction vessels and analysis chambers. A single drop of fluid provides sufficient analysis media to complete similar to 100 assays in these microetch pits. The cavities possess pyramidal pit shapes with trans-wafer openings that allows for both fluid flow through the microreactors/analysis chambers and optical access to the chemically sensitive microspheres. Identification and quantitation of analytes occurs via colorimetric and fluorescence changes to receptor and indicator molecules that are covalently attached to termination sites on the polymeric microspheres. Spectral data are extracted from the array efficiently using a charge-coupled device allowing for the near-real-time digital analysis of complex fluids. The power and utility of this new microbead array detection methodology is demonstrated here for the analysis of complex fluids containing a variety of important classes of analytes including acids, bases, metal cations, metabolic cofactors, and antibody reagents.
引用
收藏
页码:2559 / 2570
页数:12
相关论文
共 77 条
  • [1] *AM PHARM BIOT, 2000, BIOD 2000 AM PHARM B
  • [2] Amatore C., 1995, PHYS ELECTROCHEMISTR, P131
  • [3] Amrani M. E. H., 1993, Materials Science & Engineering C: Biomimetic Materials, Sensors and Systems, VC1, P17, DOI 10.1016/0928-4931(93)90005-N
  • [4] [Anonymous], 1990, SIGMA ALDRICH HDB ST
  • [5] ENZYMATIC DETERMINATION OF GLUCOSE IN A FLOW SYSTEM BY CATALYTIC-OXIDATION OF THE NICOTINAMIDE COENZYME AT A MODIFIED ELECTRODE
    APPELQVIST, R
    MARKOVARGA, G
    GORTON, L
    TORSTENSSON, A
    JOHANSSON, G
    [J]. ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) : 237 - 247
  • [6] SURFACE MICROMACHINED TUNABLE INTERFEROMETER ARRAY
    ARATANI, K
    FRENCH, PJ
    SARRO, PM
    POENAR, D
    WOLFFENBUTTEL, RF
    MIDDELHOEK, S
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1994, 43 (1-3) : 17 - 23
  • [7] Protein microchips: Use for immunoassay and enzymatic reactions
    Arenkov, P
    Kukhtin, A
    Gemmell, A
    Voloshchuk, S
    Chupeeva, V
    Mirzabekov, A
    [J]. ANALYTICAL BIOCHEMISTRY, 2000, 278 (02) : 123 - 131
  • [8] New developments in particle-based immunoassays: Introduction
    Bangs, LB
    [J]. PURE AND APPLIED CHEMISTRY, 1996, 68 (10) : 1873 - 1879
  • [9] BASAVA C, 1994, PEPTIDES DESIGN SYNT
  • [10] Bodanszky M., 1993, PRINCIPLES PEPTIDE S, V2nd