The new reticulocyte parameter (RET-Y) of the Sysmex XE 2100 - Its use in the diagnosis and monitoring of posttreatment sideropenic anemia

被引:46
作者
Buttarello, M
Temporin, V
Ceravolo, R
Farina, G
Bulian, P
机构
[1] Geriatr Hosp, Dept Lab Med, Clin Pathol Lab, Padua, Italy
[2] Geriatr Hosp, Outpatient Clin, Padua, Italy
[3] S Maria Angeli Hosp, Dept Lab Med, Pordenone, Italy
关键词
reticulocyte parameters; mean reticulocyte hemoglobin content; mean reticulocyte volume; hematology analyzer; iron deficiency anemia;
D O I
10.1309/W65295DTUWK7U1HH
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
To verify their clinical usefulness in diagnosis and early response to therapy of sideropenic anemia, we compared the behavior of the reticulocyte parameter (RET-Y), a raw measure dependent on size and content of the cell, generated by the Sysmex XE 2100, with the mean reticulocyte volume (MCVr) and mean reticulocyte hemoglobin content (CHr) from the Bayer ADVIA 120 in healthy subjects and patients with iron deficiency anemia. Correlations were high (r = 0.88 and r = 0.94, respectively). All parameters varied significantly as early as 48 hours after the start of intravenous iron therapy (mean differences of 17.4% [RET-Y], 4.5% [MCVr], and 9.5% [CHr]). Sudden decreases in those parameters at interruption of therapy indicate the reappearance of sideropenic erythropoiesis. The receiver operating characteristic curve demonstrated a high degree of efficiency in differentiating moderate or severe iron deficiency anemia from the healthy state. The best association between sensitivity and specificity was at a cutoff of channel 1, 624 for RET-Y and 104.5 fL for MCVr (negative and positive predictive values, respectively, of 99.6% and 96.5% for RET-Y and 98.7% and 93.3% for MCVr). RET-Y is correlated closely with CHr and is useful for diagnosis and early monitoring after the administration of intravenous iron.
引用
收藏
页码:489 / 495
页数:7
相关论文
共 19 条
[11]   A randomized trial of iron deficiency testing strategies in hemodialysis patients [J].
Fishbane, S ;
Shapiro, W ;
Dutka, P ;
Valenzuela, OF ;
Faubert, J .
KIDNEY INTERNATIONAL, 2001, 60 (06) :2406-2411
[12]   The effect of intravenous iron on the reticulocyte response to recombinant human erythropoietin [J].
Major, A ;
MathezLoic, F ;
Rohling, R ;
Gautschi, K ;
Brugnara, C .
BRITISH JOURNAL OF HAEMATOLOGY, 1997, 98 (02) :292-294
[13]  
PAPAYANNOPOULOU T, 1975, BLOOD CELLS, V1, P535
[14]  
Parisotto R, 2001, HAEMATOLOGICA, V86, P128
[15]  
Thomas C, 2002, CLIN CHEM, V48, P1066
[16]   FLOW-CYTOMETRIC LIGHT-SCATTERING MEASUREMENT OF RED BLOOD-CELL VOLUME AND HEMOGLOBIN CONCENTRATION [J].
TYCKO, DH ;
METZ, MH ;
EPSTEIN, EA ;
GRINBAUM, A .
APPLIED OPTICS, 1985, 24 (09) :1355-1365
[17]  
[No title captured]
[18]  
[No title captured]
[19]  
[No title captured]