Comparison of immediate and follow-up results of the short and long NIR stent with the Palmaz-Schatz stent

被引:25
作者
Kobayashi, Y [1 ]
De Gregorio, J [1 ]
Kobayashi, N [1 ]
Reimers, B [1 ]
Albiero, R [1 ]
Vaghetti, M [1 ]
Finci, L [1 ]
Di Mario, C [1 ]
Colombo, A [1 ]
机构
[1] Ctr Coure Columbus, I-20145 Milan, Italy
关键词
D O I
10.1016/S0002-9149(99)00366-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The intrinsic characteristics of a stent including stent length may affect both procedural success and long-term outcome. The present study evaluated the immediate and follow-up results after implantation of the short and long NIR stent and compared these results with the Palmaz-Schatz stent. Between July 1995 and December 1996, stenting with a 16-mm NIR stent (NIR-16), a 32-mm NIR stent (NIR-32), or a Palmaz-Schatz stent (88) was performed in 68, 57, and 155 lesions, respectively. There were no significant differences in the incidences of delivery failure (PS, 2.6%: NIR-16, 4.4%; NIR-32, 5.3%; p = NS) and procedural success (PS, 92%; NIR-16, 93%; NIR-32, 93%; p NS) among the 3 groups. The reference vessel diameter was smaller in lesions with a 32-mm NIR stent than in those with a Palmaz-Schatz stent (PS, 3.14 +/- 0.58, NIR-16, 3.00 +/- 0.50; NIR-32, 2.90 +/- 0.47 mm; p <0.05). The lesion length was longer in lesions with a 32-mm NIR stent than in those with a Palmaz-Schatz or a 16-mm NIR stent (PS, 8.9 +/- 5.0; NIR-16, 11.0 +/- 4.1; NIR-32 26.1 +/- 9.7 mm; p <0.01). After the procedure, the lesions with a 32-mm NIR stent had a smaller minimal lumen diameter than those with a Palmaz-Schatz stent (PS, 3.17 +/- 0.61; NIR-16, 2.99 +/- 0.51; NIR-32, 2.89 +/- 0.49 mm; p <0.01). At follow-vp, a smaller minimal lumen diameter was observed in lesions with a 32-mm NIR stent than in those with a Palmaz-Schatz or a 16-mm NIR stent (PS, 2.32 +/- 0.98; NIR-16, 2.25 +/- 0.80; NIR-32, 1.68 +/- 0.79 mm; p <0.01). Restenosis rates were 16.5% in lesions with a Palmaz-Schatz stent, 13.3% in those with a 16-mm NIR stent, and 47.4% in those with a 32-mm NIR stent (p <0.01). Although stent delivery and procedural success of a long NIR stent were acceptable, the restenosis rate of a long NIR stent was high compared with a short NIR stent or a Palmaz-Schatz stent. (C) 1999 by Excerpta Medico, Inc.
引用
收藏
页码:499 / 504
页数:6
相关论文
共 24 条
[11]   LUMINAL LOSS AND SITE OF RESTENOSIS AFTER PALMAZ-SCHATZ CORONARY STENT IMPLANTATION [J].
IKARI, Y ;
HARA, K ;
TAMURA, T ;
SAEKI, F ;
YAMAGUCHI, T .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (03) :117-120
[12]   Intracoronary stent implantation without ultrasound guidance and with replacement of conventional anticoagulation by antiplatelet therapy - 30-day clinical outcome of the French Multicenter Registry [J].
Karrillon, GJ ;
Morice, MC ;
Benveniste, E ;
Bunouf, P ;
Aubry, P ;
Cattan, S ;
Chevalier, B ;
Commeau, P ;
Cribier, A ;
Eiferman, C ;
Grollier, G ;
Guerin, Y ;
Henry, M ;
Lefevre, T ;
Livarek, B ;
Louvard, Y ;
Marco, J ;
Makowski, S ;
Monassier, JP ;
Pernes, JM ;
Rioux, P ;
Spaulding, C ;
Zemour, G .
CIRCULATION, 1996, 94 (07) :1519-1527
[13]   THE IMPORTANCE OF ACUTE LUMINAL DIAMETER IN DETERMINING RESTENOSIS AFTER CORONARY ATHERECTOMY OR STENTING [J].
KUNTZ, RE ;
SAFIAN, RD ;
CARROZZA, JP ;
FISHMAN, RF ;
MANSOUR, M ;
BAIM, DS .
CIRCULATION, 1992, 86 (06) :1827-1835
[14]   RESTENOSIS AFTER CORONARY ANGIOPLASTY - POTENTIAL BIOLOGIC DETERMINANTS AND ROLE OF INTIMAL HYPERPLASIA [J].
LIU, MW ;
ROUBIN, GS ;
KING, SB .
CIRCULATION, 1989, 79 (06) :1374-1387
[15]  
RATNR BD, 1987, J BIOMED MATER RES-A, V21, P59
[16]  
Reifart N, 1997, CIRCULATION, V96, P91
[17]  
Reimers B, 1997, CATHETER CARDIO DIAG, V40, P343, DOI 10.1002/(SICI)1097-0304(199704)40:4<343::AID-CCD3>3.0.CO
[18]  
2-9
[19]  
RICHTER K, 1998, HDB CORONARY STENTS, P137