Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research

被引:192
作者
Antonuk, LE [1 ]
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
关键词
D O I
10.1088/0031-9155/47/6/201
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A review of electronic portal imaging devices (EPIDs) used in external beam, megavoltage radiation therapy is presented. The review consists of a brief introduction to the definition, role and clinical significance of portal imaging, along with a discussion of radiotherapy film systems and the motivations for EPIDs. This is followed by a summary of the challenges and constraints inherent to portal imaging along with a concise, historical review of the technologies that have been explored and developed. The paper then examines, in greater depth, the two first-generation technologies that have found widespread clinical use starting from the late 1980s. This is followed by a broad overview of the physics, operation, properties and advantages of active matrix, flat-panel, megavoltage imagers, presently being commercially introduced to clinical environments or expected to be introduced in the future. Finally, a survey of contemporary research efforts focused on improving portal imaging performance by addressing various weaknesses in existing commercial systems is presented.
引用
收藏
页码:R31 / R65
页数:35
相关论文
共 117 条
[1]   Experimental evaluation of a-Se and CdTe flat-panel X-ray detectors for digital radiography and fluoroscopy [J].
Adachi, S ;
Hori, N ;
Sato, K ;
Tokuda, S ;
Sato, T ;
Uehara, K ;
Izumi, Y ;
Nagata, H ;
Yoshimura, Y ;
Yamada, S .
MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 :38-47
[2]  
ANDREWS JR, 1958, AMER J ROENTGENOL RA, V79, P74
[3]  
[Anonymous], 2000, TECHNOLOGY APPL AMOR
[4]  
ANTONUK LE, 1993, MATER RES SOC SYMP P, V297, P945, DOI 10.1557/PROC-297-945
[5]  
ANTONUK LE, 1995, P SOC PHOTO-OPT INS, V2432, P216, DOI 10.1117/12.208340
[6]   Megavoltage imaging with a large-area, flat-panel, amorphous silicon imager [J].
Antonuk, LE ;
Yorkston, J ;
Huang, WD ;
Sandler, H ;
Siewerdsen, JH ;
ElMohri, Y .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (03) :661-672
[7]   Initial performance evaluation of an indirect-detection, active matrix flat-panel imager (AMFPI) prototype for megavoltage imaging [J].
Antonuk, LE ;
El-Mohri, Y ;
Huang, WD ;
Jee, KW ;
Siewerdsen, JH ;
Maolinbay, M ;
Scarpine, VE ;
Sandler, H ;
Yorkston, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (02) :437-454
[8]   DEMONSTRATION OF MEGAVOLTAGE AND DIAGNOSTIC-X-RAY IMAGING WITH HYDROGENATED AMORPHOUS-SILICON ARRAYS [J].
ANTONUK, LE ;
BOUDRY, J ;
HUANG, WD ;
MCSHAN, DL ;
MORTON, EJ ;
YORKSTON, J ;
LONGO, MJ ;
STREET, RA .
MEDICAL PHYSICS, 1992, 19 (06) :1455-1466
[9]   RADIATION RESPONSE CHARACTERISTICS OF AMORPHOUS-SILICON ARRAYS FOR MEGAVOLTAGE RADIOTHERAPY IMAGING [J].
ANTONUK, LE ;
YORKSTON, J ;
HUANG, W ;
BOUDRY, J ;
MORTON, EJ ;
LONGO, MJ ;
STREET, RA .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :1069-1073
[10]   THIN-FILM, FLAT-PANEL, COMPOSITE IMAGERS FOR PROJECTION AND TOMOGRAPHIC IMAGING [J].
ANTONUK, LE ;
BOUDRY, J ;
HUANG, WD ;
LAM, KL ;
MORTON, EJ ;
TENHAKEN, RK ;
YORKSTON, J ;
CLINTHORNE, NH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (03) :482-490