Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research

被引:192
作者
Antonuk, LE [1 ]
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
关键词
D O I
10.1088/0031-9155/47/6/201
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A review of electronic portal imaging devices (EPIDs) used in external beam, megavoltage radiation therapy is presented. The review consists of a brief introduction to the definition, role and clinical significance of portal imaging, along with a discussion of radiotherapy film systems and the motivations for EPIDs. This is followed by a summary of the challenges and constraints inherent to portal imaging along with a concise, historical review of the technologies that have been explored and developed. The paper then examines, in greater depth, the two first-generation technologies that have found widespread clinical use starting from the late 1980s. This is followed by a broad overview of the physics, operation, properties and advantages of active matrix, flat-panel, megavoltage imagers, presently being commercially introduced to clinical environments or expected to be introduced in the future. Finally, a survey of contemporary research efforts focused on improving portal imaging performance by addressing various weaknesses in existing commercial systems is presented.
引用
收藏
页码:R31 / R65
页数:35
相关论文
共 117 条
[31]   Use of a kinestatic charge detector for megavoltage portal imaging [J].
DiBianca, F ;
Samant, S ;
Laughter, J ;
Rasmussen, J ;
Rodriguez, C .
PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 :195-201
[32]   Initial clinical performance of a large-field KCD digital radiography system [J].
DiBianca, F ;
Rodriguez, C ;
Devidas, S ;
Emerson, D ;
Gaber, MW ;
Giakos, G ;
Gold, R ;
Jordan, L ;
Kaufman, R ;
Kollipara, S ;
Laughter, J ;
Mahmud, A ;
Nagarajan, S ;
Peng, Q ;
Price, PJ ;
Sebes, J ;
Zeman, H ;
Zhu, ZP .
PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 :826-836
[33]   KINESTATIC CHARGE DETECTION [J].
DIBIANCA, FA ;
BARKER, MD .
MEDICAL PHYSICS, 1985, 12 (03) :339-343
[34]   Development of a novel, high contrast, cassette/film/screen system for radiation therapy portal localization imaging [J].
Dickerson, RE ;
Haus, AG ;
Huff, KE .
PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 :520-529
[35]   DQE(F) OF 4 GENERATIONS OF COMPUTED RADIOGRAPHY ACQUISITION DEVICES [J].
DOBBINS, JT ;
ERGUN, DL ;
RUTZ, L ;
HINSHAW, DA ;
BLUME, H ;
CLARK, DC .
MEDICAL PHYSICS, 1995, 22 (10) :1581-1593
[36]   Characterization of a fluoroscopic imaging system for kV and MV radiography [J].
Drake, DG ;
Jaffray, DA ;
Wong, JW .
MEDICAL PHYSICS, 2000, 27 (05) :898-905
[37]   A prototype amorphous silicon array based radiotherapy portal imager [J].
Drake, DG ;
Jaffray, DA ;
Wong, JW .
PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 :32-41
[38]   Modulation transfer function for a large-area amorphous silicon image receptor [J].
Earnhart, JRD ;
Chaney, EL .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (12) :2531-2540
[39]   Relative dosimetry using active matrix flat-panel imager (AMFPI) technology [J].
El-Mohri, Y ;
Antonuk, LE ;
Yorkston, J ;
Jee, KW ;
Maolinbay, M ;
Lam, KL ;
Siewerdsen, JH .
MEDICAL PHYSICS, 1999, 26 (08) :1530-1541
[40]   Determination of the detective quantum efficiency of a prototype, megavoltage indirect detection, active matrix flat-panel imager [J].
El-Mohri, Y ;
Jee, KW ;
Antonuk, LE ;
Maolinbay, M ;
Zhao, QH .
MEDICAL PHYSICS, 2001, 28 (12) :2538-2550