Single PEM Fuel Cell Analysis for the Evaluation of Current Ripple Effects

被引:31
作者
Ferrero, Roberto [1 ]
Marracci, Mirko [2 ]
Tellini, Bernardo [2 ]
机构
[1] Politecn Milan, Dept Elect Engn, I-20133 Milan, Italy
[2] Univ Pisa, Dept Energy & Syst Engn, I-56122 Pisa, Italy
关键词
Current ripple; equivalent circuit; fuel cell (FC); hysteresis; impedance spectroscopy; IMPEDANCE; MODEL;
D O I
10.1109/TIM.2012.2232432
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the results of an experimental analysis performed on a polymer electrolyte membrane fuel cell (FC) for the evaluation of the current ripple effects are reported. The polarization curve (PC) and the impedance spectrum measured for a single FC with a Nafion membrane are presented discussing some advantages and disadvantages of the two adopted techniques from the measurement point of view. The ohmic and activation resistance values provided by the PC are compared to the frequency limits of the equivalent resistance estimated by the spectroscopic analysis to evaluate the additional losses and the system efficiency reduction introduced by the current ripple. The presence of a voltage-current hysteretic behavior is discussed throughout the paper, and some comments on how such a relationship can impact on the identification of the indicated parameters are included.
引用
收藏
页码:1058 / 1064
页数:7
相关论文
共 25 条
[1]   Frequency dependent parameter model of supercapacitor [J].
Barsali, S. ;
Ceraolo, M. ;
Marracci, M. ;
Tellini, B. .
MEASUREMENT, 2010, 43 (10) :1683-1689
[2]  
Barsoukov E, 2005, IMPEDANCE SPECTROSCOPY: THEORY, EXPERIMENT, AND APPLICATIONS, 2ND EDITION, pXII
[3]   Impedance-based simulation models of supercapacitors and Li-ion batteries for power electronic applications [J].
Buller, S ;
Thele, M ;
De Doncker, RWAA ;
Karden, E .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (03) :742-747
[4]   Development of an equivalent circuit model of a fuel cell to evaluate the effects of inverter ripple current [J].
Choi, Woojin ;
Howze, Jo. W. ;
Enjeti, Prasad .
JOURNAL OF POWER SOURCES, 2006, 158 (02) :1324-1332
[5]   Electrical test methods for on-line fuel cell ohmic resistance measurement [J].
Cooper, K. R. ;
Smith, M. .
JOURNAL OF POWER SOURCES, 2006, 160 (02) :1088-1095
[6]  
EG&G Technical Services Inc, 2004, FUEL CELL HDB
[7]  
Ewing J.A., 1885, PHILOS T ROYAL SOC L, V176, P523
[8]  
Ferrero R, 2012, IEEE IMTC P, P52
[9]   Simplified model for evaluating ripple effects on commercial PEM fuel cell [J].
Ferrero, R. ;
Marracci, M. ;
Prioli, M. ;
Tellini, B. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2012, 37 (18) :13462-13469
[10]   Model based PEM fuel cell state-of-health monitoring via ac impedance measurements [J].
Fouquet, N. ;
Doulet, C. ;
Nouillant, C. ;
Dauphin-Tanguy, G. ;
Ould-Bouamama, B. .
JOURNAL OF POWER SOURCES, 2006, 159 (02) :905-913