Metal-on-metal bearings surfaces: materials, manufacture, design, optimization, and alternatives

被引:48
作者
Isaac, GH
Thompson, J
Williams, S
Fisher, J
机构
[1] Depuy Int Ltd, Number One, Leeds LS11 0EA, W Yorkshire, England
[2] Univ Leeds, Inst Med & Biol Engn, Leeds, W Yorkshire, England
关键词
total hip replacement; wear; hard-on-hard bearings; metal-on-metal bearings; ceramics; polyethylene;
D O I
10.1243/095441105X68953
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
When first introduced, total hip replacements offered pain relief and improved mobility in elderly patients. The success of this procedure in terms of long-term durability and restoration of function has led to its use in younger, more active patients. This has resulted in a commensurate increase in patient expectation regarding longevity and the degree to which function and lifestyle is restored. The bearing surface is a key feature of the performance of replacement joints. It is generally accepted that excessive amounts of wear debris preclude their long-term survivorship and hence there is an ongoing requirement for bearing surfaces which minimize debris generation. The purpose of this paper is to review the factors which affect the performance of so-called metal-on-metal bearings, to compare their performance with that of the other commonly used contemporary alternatives, metal and ceramic articulating against highly cross-linked polyethylene, and ceramic-on-ceramic, and finally to consider the potential solutions offered by new developments such as ceramic-on-metal and coatings applied to metal-on-metal bearings.
引用
收藏
页码:119 / 133
页数:15
相关论文
共 74 条
[1]  
[Anonymous], CLIN ORTHOP
[2]   A hip joint simulator study using new and physiologically scratched femoral heads with ultra-high molecular weight polyethylene acetabular cups [J].
Barbour, PSM ;
Stone, MH ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H6) :569-576
[3]   Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation [J].
Besong, AA ;
Tipper, JL ;
Ingham, E ;
Stone, MH ;
Wroblewski, BM ;
Fisher, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :340-344
[4]  
BIZOT P, 2000, CLIN ORTHOP RELAT R, V379, P134
[5]   SYSTEMIC EFFECTS OF BIOMATERIALS [J].
BLACK, J .
BIOMATERIALS, 1984, 5 (01) :11-18
[6]   THE USE OF DENSE ALUMINA ALUMINA CERAMIC COMBINATION IN TOTAL HIP-REPLACEMENT [J].
BOUTIN, P ;
CHRISTEL, P ;
DORLOT, JM ;
MEUNIER, A ;
DEROQUANCOURT, A ;
BLANQUAERT, D ;
HERMAN, S ;
SEDEL, L ;
WITVOET, J .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (12) :1203-1232
[7]  
BOWSHER JG, 2003, T 49 ANN M ORTH RES
[8]   Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners [J].
Bradford, L ;
Baker, DA ;
Graham, J ;
Chawan, A ;
Ries, MD ;
Pruitt, LA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (06) :1271-1282
[9]   A tribological study of cobalt chromium molybdenum alloys used in metal-on-metal resurfacing hip arthroplasty [J].
Cawley, J ;
Metcalf, JEP ;
Jones, AH ;
Band, TJ ;
Skupien, DS .
WEAR, 2003, 255 :999-1006
[10]  
Chan FW, 1999, CLIN ORTHOP RELAT R, P10