Is high-throughput measurement of 25-hydroxyvitamin D3 without 25-hydroxyvitamin D2 appropriate for routine clinical use?

被引:11
作者
Costelloe, S. J. [1 ]
Woolman, E. [1 ]
Rainbow, S. [2 ]
Stratiotis, L. [1 ]
O'Garro, G. [1 ]
Whiting, S. [1 ]
Thomas, M. [1 ]
机构
[1] Royal Free Hosp, Dept Clin Biochem, London NW3 2QG, England
[2] Northwick Pk Hosp & Clin Res Ctr, Dept Clin Biochem, Harrow HA1 3UJ, Middx, England
关键词
VITAMIN-D-3; ACCURATE;
D O I
10.1258/acb.2008.008157
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
引用
收藏
页码:86 / 87
页数:2
相关论文
共 9 条
[1]   Vitamin D2 is much less effective than vitamin D3 in humans [J].
Armas, LAG ;
Hollis, BW ;
Heaney, RP .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2004, 89 (11) :5387-5391
[2]   Laboratory reporting of 25-hydroxyvitamin D results: Potential for clinical misinterpretation [J].
Binkley, Neil ;
Drezner, Marc K. ;
Hollis, Bruce W. .
CLINICAL CHEMISTRY, 2006, 52 (11) :2124-2125
[3]   How accurate are assays for 25-hydroxyvitamin D? Data from the international vitamin D external quality assessment scheme [J].
Carter, GD ;
Carter, R ;
Jones, J ;
Berry, J .
CLINICAL CHEMISTRY, 2004, 50 (11) :2195-2197
[4]   Vitamin D2 is as effective as vitamin D3 in maintaining circulating concentrations of 25-hydroxyvitamin D [J].
Holick, Michael F. ;
Biancuzzo, Rachael M. ;
Chen, Tai C. ;
Klein, Ellen K. ;
Young, Azzie ;
Bibuld, Douglass ;
Reitz, Richard ;
Salameh, Wael ;
Ameri, Allen ;
Tannenbaum, Andrew D. .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2008, 93 (03) :677-681
[5]   The case against ergocalciferol (vitamin D2) as a vitamin supplement [J].
Houghton, Lisa A. ;
Vieth, Reinhold .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2006, 84 (04) :694-697
[6]   Self-prescribed high-dose vitamin D3:: effects on biochemical parameters in two men [J].
Kimball, Samantha ;
Vieth, Reinhold .
ANNALS OF CLINICAL BIOCHEMISTRY, 2008, 45 :106-110
[7]   Vitamin D Nutrition and Bone Disease in Adults [J].
Mawer E.B. ;
Davies M. .
Reviews in Endocrine and Metabolic Disorders, 2001, 2 (2) :153-164
[8]   Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography-tandem mass spectrometry as a reference [J].
Roth, Heinz Juergen ;
Schmidt-Gayk, Heinrich ;
Weber, Holger ;
Niederau, Christoph .
ANNALS OF CLINICAL BIOCHEMISTRY, 2008, 45 :153-159
[9]   Are clinical laboratories prepared for accurate testing of 25-hydroxy vitamin D? [J].
Singh, Ravinder J. .
CLINICAL CHEMISTRY, 2008, 54 (01) :221-223