Comparison of pure and hybrid iterative reconstruction techniques with conventional filtered back projection: Image quality assessment in the cervicothoracic region

被引:47
作者
Katsura, Masaki [1 ]
Sato, Jiro [1 ]
Akahane, Masaaki [1 ]
Matsuda, Izuru [1 ]
Ishida, Masanori [1 ]
Yasaka, Koichiro [1 ]
Kunimatsu, Akira [1 ]
Ohtomo, Kuni [1 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Radiol, Bunkyo Ku, Tokyo 1138655, Japan
关键词
Model-based iterative reconstruction; Adaptive statistical iterative reconstruction; Filtered back projection; Streak artifact; Image noise; Cervicothoracic region; DOSE REDUCTION; CT ANGIOGRAPHY;
D O I
10.1016/j.ejrad.2012.11.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Objectives: To evaluate the impact on image quality of three different image reconstruction techniques in the cervicothoracic region: model-based iterative reconstruction (MBIR), adaptive statistical iterative reconstruction (ASIR), and filtered back projection (FBP). Methods: Forty-four patients underwent unenhanced standard-of-care clinical computed tomography (CT) examinations which included the cervicothoracic region with a 64-row multidetector CT scanner. Images were reconstructed with FBP, 50% ASIR-FBP blending (ASIR50), and MBIR. Two radiologists assessed the cervicothoracic region in a blinded manner for streak artifacts, pixilated blotchy appearances, critical reproduction of visually sharp anatomical structures (thyroid gland, common carotid artery, and esophagus), and overall diagnostic acceptability. Objective image noise was measured in the internal jugular vein. Data were analyzed using the sign test and pair-wise Student's t-test. Results: MBIR images had significant lower quantitative image noise (8.88 +/- 1.32) compared to ASIR images (18.63 +/- 4.19, P < 0.01) and FBP images (26.52 +/- 5.8, P < 0.01). Significant improvements in streak artifacts of the cervicothoracic region were observed with the use of MBIR (P < 0.001 each for MBIR vs. the other two image data sets for both readers), while no significant difference was observed between ASIR and FBP (P > 0.9 for ASIR vs. FBP for both readers). MBIR images were all diagnostically acceptable. Unique features of MBIR images included pixilated blotchy appearances, which did not adversely affect diagnostic acceptability. Conclusions: MBIR significantly improves image noise and streak artifacts of the cervicothoracic region over ASIR and FBP. MBIR is expected to enhance the value of CT examinations for areas where image noise and streak artifacts are problematic. (c) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:356 / 360
页数:5
相关论文
共 16 条
[1]
Impact of Adaptive Statistical Iterative Reconstruction (ASIR) on Radiation Dose and Image Quality in Aortic Dissection Studies: A Qualitative and Quantitative Analysis [J].
Cornfeld, Daniel ;
Israel, Gary ;
Detroy, Ezra ;
Bokhari, Jamal ;
Mojibian, Hamid .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (03) :W336-W340
[2]
*EUR, 16262 EUR
[3]
Reducing the Radiation Dose for CT Colonography Using Adaptive Statistical Iterative Reconstruction: A Pilot Study [J].
Flicek, Kristina T. ;
Hara, Amy K. ;
Silva, Alvin C. ;
Wu, Qing ;
Peter, Mary B. ;
Johnson, C. Daniel .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (01) :126-131
[4]
Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study [J].
Hara, Amy K. ;
Paden, Robert G. ;
Silva, Alvin C. ;
Kujak, Jennifer L. ;
Lawder, Holly J. ;
Pavlicek, William .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) :764-771
[5]
Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique [J].
Katsura, Masaki ;
Matsuda, Izuru ;
Akahane, Masaaki ;
Sato, Jiro ;
Akai, Hiroyuki ;
Yasaka, Koichiro ;
Kunimatsu, Akira ;
Ohtomo, Kuni .
EUROPEAN RADIOLOGY, 2012, 22 (08) :1613-1623
[6]
A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction [J].
Leipsic, Jonathon ;
Nguyen, Giang ;
Brown, Jaqueline ;
Sin, Don ;
Mayo, John R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) :1095-1099
[7]
Adaptive Statistical Iterative Reconstruction: Assessment of Image Noise and Image Quality in Coronary CT Angiography [J].
Leipsic, Jonathon ;
LaBounty, Troy M. ;
Heilbron, Brett ;
Min, James K. ;
Mancini, G. B. John ;
Lin, Fay Y. ;
Taylor, Carolyn ;
Dunning, Allison ;
Earls, James P. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) :649-654
[8]
Reducing Abdominal CT Radiation Dose With Adaptive Statistical Iterative Reconstruction Technique [J].
Prakash, Priyanka ;
Kalra, Mannudeep K. ;
Kambadakone, Avinash K. ;
Pien, Homer ;
Hsieh, Jiang ;
Blake, Michael A. ;
Sahani, Dushyant V. .
INVESTIGATIVE RADIOLOGY, 2010, 45 (04) :202-210
[9]
Radiation Dose Reduction With Chest Computed Tomography Using Adaptive Statistical Iterative Reconstruction Technique: Initial Experience [J].
Prakash, Priyanka ;
Kalra, Mannudeep K. ;
Digumarthy, Subba R. ;
Hsieh, Jiang ;
Pien, Homer ;
Singh, Sarabjeet ;
Gilman, Matthew D. ;
Shepard, Jo-Anne O. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (01) :40-45
[10]
Abdominal CT: Comparison of Low-Dose CT With Adaptive Statistical Iterative Reconstruction and Routine-Dose CT With Filtered Back Projection in 53 Patients [J].
Sagara, Yoshiko ;
Hara, Amy K. ;
Pavlicek, William ;
Silva, Alvin C. ;
Paden, Robert G. ;
Wu, Qing .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) :713-719