Patch technique for repair of a dural tear in microendoscopic spinal surgery

被引:22
作者
Shibayama, M. [1 ]
Mizutani, J. [1 ]
Takahashi, I. [1 ]
Nagao, S. [1 ]
Ohta, H. [1 ]
Otsuka, T. [1 ]
机构
[1] Toyokawa City Hosp, Aichi, Japan
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2008年 / 90B卷 / 08期
关键词
D O I
10.1302/0301-620X.90B8.20938
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A dural tear is a common but troublesome complication of endoscopic spinal surgery. The limitations of space make repair difficult, and it is often necessary to proceed to an open operation to suture the dura in order to prevent leakage of cerebrospinal fluid. We describe a new patch technique in which a small piece of polyglactin 910 is fixed to the injured dura with fibrin glue. Three pieces are generally required to obtain a watertight closure after lavage with saline. We have applied this technique in seven cases. All recovered well with no adverse effects. MRI showed no sign of leakage of cerebrospinal fluid.
引用
收藏
页码:1066 / 1067
页数:2
相关论文
共 10 条
[1]  
Foley KT, 1997, Tech Neurosurg, V3, P301
[2]   Nonsuture dural repair using polyglycolic acid mesh and fibrin glue: Clinical application to spinal surgery [J].
Hida, K ;
Yamaguchi, S ;
Seki, T ;
Yano, S ;
Akino, M ;
Terasaka, S ;
Uchida, T ;
Iwasaki, Y .
SURGICAL NEUROLOGY, 2006, 65 (02) :136-143
[3]   Short-term results of microendoscopic posterior decompression for lumbar spinal stenosis - Technical note [J].
Ikuta, K ;
Arima, J ;
Tanaka, T ;
Oga, M ;
Nakano, S ;
Sasaki, K ;
Goshi, K ;
Yo, M ;
Fukagawa, S .
JOURNAL OF NEUROSURGERY-SPINE, 2005, 2 (05) :624-633
[4]   Microendoscopic decompressive laminotomy for the treatment of lumbar stenosis [J].
Khoo, LT ;
Fessler, RG .
NEUROSURGERY, 2002, 51 (05) :S146-S154
[5]   VICRYL (POLYGLACTIN-910) MESH AS A DURAL SUBSTITUTE [J].
MAURER, PK ;
MCDONALD, JV .
JOURNAL OF NEUROSURGERY, 1985, 63 (03) :448-452
[6]  
Nagata K, 1999, NEUROL MED-CHIR, V39, P316, DOI 10.2176/nmc.39.316
[7]   VICRYL (POLYGLACTIN-910) MESH AS A DURAL SUBSTITUTE IN THE PRESENCE OF PIA ARACHNOID INJURY [J].
NUSSBAUM, CE ;
MAURER, PK ;
MCDONALD, JV .
JOURNAL OF NEUROSURGERY, 1989, 71 (01) :124-127
[8]   Bilateral decompression of lumbar spinal stenosis involving a unilateral approach with microscope and tubular retractor system [J].
Palmer, S ;
Turner, R ;
Palmer, R .
JOURNAL OF NEUROSURGERY, 2002, 97 (02) :213-217
[9]   Dural substitute with polyglycolic acid mesh and fibrin glue for dural repair: technical note and preliminary results [J].
Shimada, Yoichi ;
Hongo, Michio ;
Miyakoshi, Naohisa ;
Sugawara, Taku ;
Kasukawa, Yuji ;
Ando, Shigeru ;
Ishikawa, Yoshinori ;
Itoi, Eiji .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2006, 11 (05) :454-458
[10]   NOVEL DURAL CLOSURE TECHNIQUE USING POLYGLACTIN ACID SHEET PREVENTS CEREBROSPINAL FLUID LEAKAGE AFTER SPINAL SURGERY [J].
Sugawara, Taku ;
Itoh, Yasunobu ;
Hirano, Yoshitaka ;
Higashiyama, Naoki ;
Shimada, Yoichi ;
Kinouchi, Hiroyuki ;
Mizoi, Kazuo .
NEUROSURGERY, 2005, 57 (04) :290-294