Quantitative comparisons of continuous and pulsed low dose rate regimens in a model late-effect system

被引:37
作者
Brenner, DJ
Hall, EJ
RandersPehrson, G
Huang, YP
Johnson, GW
Miller, RW
Wu, B
Vazquez, ME
Medvedovsky, C
Worgul, BV
机构
[1] COLUMBIA UNIV, INST COMPARAT MED, NEW YORK, NY 10032 USA
[2] COLUMBIA UNIV, EYE RADIAT & ENVIRONM RES LAB, NEW YORK, NY 10032 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1996年 / 34卷 / 04期
关键词
brachytherapy; pulsed dose rate; late effects;
D O I
10.1016/0360-3016(95)02182-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: There is increasing interest and usage of pulsed low dose rate (PDR) brachytherapy, in which a single source is shuttled through the catheters of an implant, typically for about 10 min each hour. This study was designed to compare the late effects produced in various PDR regimens with those from the corresponding continuous low dose rate (CLDR) regimens. Methods and Materials: A model late-responding system was used, namely, cataract induction in the rat lens. This system has the advantage of being highly quantifiable. The rats eyes were exposed to a total dose of 15 Gy either continuously over 24 h, or with three different PDR regimens, all with the same total dose and overall time. We addressed three questions: (a) are late effects increased when a CLDR regimen is replaced with 10-min pulses repeated every hour? (b) Are late effects increased if hourly 10-min pulses are replaced with 10-min pulses repeated every 4 h? (c) Are late effects increased if 10-min pulses are replaced with 100-s pulses? Results: We found that the four regimens under test, continuous, 10-min pulses each hour, 10-min pulses every 4 h, and 100-s pulses every hour, showed no significant differences in cataractogenic potential, as estimated with the Wilcoxon-Gehan test. Power tests indicated that the experimental design was adequate to detect relatively small differences in cataractogenicity between regimens. Conclusions: The equality of late effects from CLDR and PDR in these experiments must imply that sublethal damage repair is quite slow in this model late-responding system, in agreement with trends observed in the clinic for sublethal damage repair of late sequelae. Such trends would suggest that PDR is unlikely to produce significantly worse late effects than the corresponding CLDR regimen, which is in agreement with early clinical data using PDR. Caution, however, is strongly recommended.
引用
收藏
页码:905 / 910
页数:6
相关论文
共 30 条
[21]  
MCLEAN M, 1994, ACTIVITY INT NUCLETR, V5, P6
[22]  
MERRIAM G R Jr, 1962, Trans Am Ophthalmol Soc, V60, P35
[23]   ACCELERATED HEAVY-PARTICLES AND THE LENS .1. CATARACTOGENIC POTENTIAL [J].
MERRIAM, GR ;
WORGUL, BV ;
MEDVEDOVSKY, C ;
ZAIDER, M ;
ROSSI, HH .
RADIATION RESEARCH, 1984, 98 (01) :129-140
[24]   TIME-DOSE RELATIONSHIPS IN EXPERIMENTAL RADIATION CATARACTOGENESIS [J].
SCHENKEN, LL ;
HAGEMANN, RF .
RADIOLOGY, 1975, 117 (01) :193-198
[25]  
SWIFT PS, 1994, ACTIVITY INT NUCL RA, V5, P29
[26]   REPAIR CAPACITY AND KINETICS OF HUMAN-SKIN DURING FRACTIONATED RADIOTHERAPY - ERYTHEMA, DESQUAMATION, AND TELANGIECTASIA AFTER 3 AND 5 YEARS FOLLOW-UP [J].
TURESSON, I ;
THAMES, HD .
RADIOTHERAPY AND ONCOLOGY, 1989, 15 (02) :169-188
[27]  
VANEIJKEREN M, 1994, ACTIVITY INT NUCL RA, V5, P6
[28]  
WHITE J, 1993, 41 ANN M RAD RES SOC
[29]  
WILCOXON F, 1945, BIOMETRICS BULL, V1, P80, DOI 10.1093/jee/39.2.269
[30]  
WORGUL BV, 1993, INVEST OPHTH VIS SCI, V34, P184