Midterm Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty

被引:49
作者
Hamilton, William G. [1 ,2 ]
McAuley, James P. [3 ]
Blumenfeld, Thomas J. [4 ]
Lesko, James P. [5 ]
Himden, Sam E. [5 ]
Dennis, Douglas A. [6 ]
机构
[1] Anderson Orthopaed Res Inst, Alexandria, VA 22307 USA
[2] Mt Vernon Hosp, Inova Ctr Joint Replacement, Alexandria, VA USA
[3] London Hlth Sci Ctr Univ Hosp, London, ON, Canada
[4] Joint Surg Sacramento, Sacramento, CA USA
[5] DePuy, Warsaw, IN USA
[6] Colorado Joint Replacement, Denver, CO USA
关键词
total hip arthroplasty; ceramic; outcome; total hip replacement; bearing surfaces; RANDOMIZED CONTROLLED-TRIAL; CROSS-LINKED POLYETHYLENE; ACETABULAR COMPONENT; FEMORAL-HEAD; FOLLOW-UP; SQUEAKING HIP; WEAR ANALYSIS; PRESS-FIT; FRACTURE; DISLOCATION;
D O I
10.1016/j.arth.2015.02.047
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
This study reports mid-term results of Delta ceramic on ceramic (COC) in total hip arthroplasty (THA). Subjects received Delta COC THA in a prospective multi-center study with either 28 mm (n=177) or 36 mm(n=168) articulations. Annual clinical and radiographic evaluations were performed, and patients were asked about hip noises. At mean 5.3-year follow-up there were 3 (0.9%) post-operative liner fractures. Nine revisions were performed (2 liner fracture, 4 stem loosening, 3 deep infection). Kaplan-Meier survivorship at 6 years was 96.9% (94.0-98.4). Twenty-six (7.5%) subjects reported squeaking, of whom none were revised. One (0.3%) subject could reproduce a sound in clinic. More patients reported squeaking with a 36 mm bearing (28 mm: 7/177, 36 mm: 19/168, P=0.013). (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:110 / 115
页数:6
相关论文
共 58 条
[1]
Revision total hip arthroplasty performed after fracture of a ceramic femoral head - A multicenter survivorship study [J].
Allain, J ;
Roudot-Thoraval, F ;
Delecrin, J ;
Anract, P ;
Migaud, H ;
Goutallier, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (05) :825-830
[2]
Comparison of Surgical Outcomes and Implant Wear Between Ceramic-Ceramic and Ceramic-Polyethylene Articulations in Total Hip Arthroplasty [J].
Amanatullah, Derek F. ;
Landa, Joshua ;
Strauss, Eric J. ;
Garino, Jonathan P. ;
Kim, Sunny H. ;
Di Cesare, Paul E. .
JOURNAL OF ARTHROPLASTY, 2011, 26 (06) :72-77
[3]
[Anonymous], J ARTHROPLASTY
[4]
Polyethylene in total joint arthroplasty - A dead end for permanent implants? [J].
Badorf, D ;
Willmann, G .
BIOMEDIZINISCHE TECHNIK, 1998, 43 (05) :151-154
[5]
Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty [J].
Berry, DJ ;
Von Knoch, M ;
Schleck, CD ;
Harmsen, WS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (11) :2456-2463
[6]
Bizot P, 2001, CLIN ORTHOP RELAT R, P85
[7]
Ceramic-on-Ceramic Total Hip Arthroplasty: Update [J].
Capello, William N. ;
D'Antonio, James A. ;
Feinberg, Judy R. ;
Manley, Michael T. ;
Naughton, Marybetb .
JOURNAL OF ARTHROPLASTY, 2008, 23 (07) :39-43
[8]
Fracture of a Titanium Sleeve-encased Third-generation Ceramic Liner in a Modern THA [J].
Chotai, Pranit N. ;
Su, Edwin P. .
ORTHOPEDICS, 2011, 34 (10) :E682-E684
[9]
Ceramic Bearings for Total Hip Arthroplasty Have High Survivorship at 10 Years [J].
D'Antonio, James A. ;
Capello, William N. ;
Naughton, Marybeth .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (02) :373-381
[10]
Fracture of the ABC® ceramic liner -: A report of three cases [J].
Diwanji, Sanket R. ;
Seon, Jong Kenn ;
Song, Eun. Kyoo ;
Yoon, Taek Rim .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (464) :242-246