Quantitative analysis of fentanyl in rat plasma by gas chromatography with nitrogen-phosphorus detection

被引:29
作者
Choi, HS
Shin, HC
Khang, G
Rhee, JM
Lee, HB
机构
[1] Korea Res Inst Chem Technol, Biomat Lab, Taejon 305606, South Korea
[2] Chonbuk Natl Univ, Dept Polymer Sci & Technol, Chonju 561756, South Korea
[3] Korea Res Inst Chem Technol, Toxicol Res Ctr, Pharmacokinet & Toxicokinet Lab, Taejon 305606, South Korea
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2001年 / 765卷 / 01期
关键词
D O I
10.1016/S0378-4347(01)00405-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive assay method was developed to determine fentanyl, an opiate agonist, in rat plasma by gas chromatography with nitrogen-phosphorus detection. For the pretreatment of plasma samples, sodium hydroxide was added to denature protein and n-butyl chloride was used to extract fentanyl. The calibration curve was linear within the concentration range 0.5 to 50 ng/ml (r=0.9997). The limit of detection was 0.1 ng/ml, and 0.5 ng/ml could be quantified with acceptable precision. Furthermore, fentanyl could be determined in only 200 mul of rat plasma. The method has been successfully applied to an intramuscular pharmacokinetic study at a dose of 10 mug/kg. Therefore, the current method is a valuable analytical tool for investigating the pharmacokinetics of fentanyl at low clinical doses. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:63 / 69
页数:7
相关论文
共 37 条
[11]  
IKEDA R, 1990, WESTERN J MED, V152, P617
[12]  
Janssen P.A., 1985, OPIOIDS ANESTHESIA, P37
[13]   QUANTITATIVE-ANALYSIS OF FENTANYL IN PHARMACEUTICAL PREPARATIONS BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
KINGSBURY, DP ;
MAKOWSKI, GS ;
STONE, JA .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1995, 19 (01) :27-30
[14]   SENSITIVE GAS-LIQUID-CHROMATOGRAPHY METHOD FOR THE DETERMINATION OF FENTANYL CONCENTRATIONS IN BLOOD [J].
KOWALSKI, SR ;
GOURLAY, GK ;
CHERRY, DA ;
MCLEAN, CF .
JOURNAL OF PHARMACOLOGICAL METHODS, 1987, 18 (04) :347-355
[15]   DETERMINATION OF FENTANYL AND ALFENTANIL IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION [J].
KUMAR, K ;
MORGAN, DJ ;
CRANKSHAW, DP .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 419 :464-468
[16]   A sensitive assay for the simultaneous measurement of alfentanil and fentanyl in plasma [J].
Kumar, K ;
Ballantyne, JA ;
Baker, AB .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (06) :667-673
[17]   GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC ANALYSIS OF ALFENTANIL METABOLITES - APPLICATION TO HUMAN LIVER MICROSOMAL ALFENTANIL BIOTRANSFORMATION [J].
LABROO, R ;
KHARASCH, ED .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 660 (01) :85-94
[18]   Comparison of pharmacokinetics of fentanyl after intravenous and transdermal administration in cats [J].
Lee, DD ;
Papich, MG ;
Hardie, EM .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2000, 61 (06) :672-677
[19]   A FENTANYL FATALITY INVOLVING MIDAZOLAM [J].
LEVINE, B ;
GOODIN, JC ;
CAPLAN, YH .
FORENSIC SCIENCE INTERNATIONAL, 1990, 45 (03) :247-251
[20]  
MARCHALL BE, 1990, PHARMACOL BASIS THER, P305