Determination of hydrogen peroxide by using a flow injection system with immobilized peroxidase and long pathlength capillary spectrophotometry

被引:58
作者
Pappas, AC [1 ]
Stalikas, CD [1 ]
Fiamegos, YC [1 ]
Karayannis, MI [1 ]
机构
[1] Univ Ioannina, Dept Chem, Lab Analyt Chem, Ioannina 45110, Greece
关键词
hydrogen peroxide; liquid waveguide capillary cell; immobilized peroxidase; flow injection analysis;
D O I
10.1016/S0003-2670(01)01600-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a highly sensitive method for the determination of nanomolar concentrations of hydrogen peroxide in the liquid phase is described. This paper demonstrates for the first time a flow injection analysis (FIA) system with immobilized enzyme reactor combined with a total internal reflective cell (a liquid waveguide capillary cell (LWCC)) and spectrophotometric detection, for the development of an improved procedure for the determination of hydrogen peroxide. Moreover, the newly synthesized 4-aminopyrazolone derivative, 4-amino-5-(p-aminophenyl)-1-methyl-2-phenyl-pyrazol-3-one (DAP), is used as a color coupler in its oxidative condensation with the sodium salt of N-ethyl-N-sulphopropylaniline sodium salt (ALPS) which acts as a hydrogen donor. Immobilization of peroxidase is achieved by coupling the periodate-treated enzyme to aminopropyl controlled-pore glass (CPG) beads. The determination of hydrogen peroxide is carried out in a 0.1 M phosphate buffer and the product is monitored at 590 nm with a charge-coupled device (CCD) detector equipped with fiber optics in a fully computerized system. The interference of different species, mainly ionic, was investigated. The method permits detection down to 4 nmol l(-1) hydrogen peroxide (signal-to-noise ratio = 3). A linear calibration graph was obtained over the range 20-700 nmol l(-1). The relative standard deviation (R.S.D.) at 300 nmol l(-1) H,02 is 1.7% (n = 7), The method was successfully applied for the determination of hydrogen peroxide in samples from a vat-cleaning process. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:305 / 313
页数:9
相关论文
共 36 条
[1]   IMPROVED COLOR REAGENT FOR DETERMINATION OF BLOOD-GLUCOSE BY OXIDASE SYSTEM [J].
BARHAM, D ;
TRINDER, P .
ANALYST, 1972, 97 (1151) :142-&
[2]   EVIDENCE FOR HEME PI-CATION RADICAL SPECIES IN COMPOUND I OF HORSERADISH-PEROXIDASE AND CATALASE [J].
BROWETT, WR ;
STILLMAN, MJ .
BIOCHIMICA ET BIOPHYSICA ACTA, 1981, 660 (01) :1-7
[3]  
Carr P.W., 1980, IMMOBILIZED ENZYMES
[4]   Reagentless amperometric determination of hydrogen peroxide by silica sol-gel modified biosensor [J].
Chut, SL ;
Li, J ;
Tan, SN .
ANALYST, 1997, 122 (11) :1431-1434
[5]   KINETICS OF FORMATION OF HORSERADISH-PEROXIDASE COMPOUND-I BY REACTION WITH PEROXOBENZOIC ACIDS - PH AND PEROXO ACID SUBSTITUENT EFFECTS [J].
DAVIES, DM ;
JONES, P ;
MANTLE, D .
BIOCHEMICAL JOURNAL, 1976, 157 (01) :247-253
[6]   Hydrogen peroxide assay by using enhanced chemiluminescence of the luminol-H2O2-horseradish peroxidase system: Comparative studies [J].
Diaz, AN ;
Sanchez, FG ;
Garcia, JAG .
ANALYTICA CHIMICA ACTA, 1996, 327 (02) :161-165
[7]   FUNCTION AND MECHANISM OF ACTION OF PEROXIDASES [J].
DUNFORD, HB ;
STILLMAN, JS .
COORDINATION CHEMISTRY REVIEWS, 1976, 19 (03) :187-251
[8]   Synthesis and analytical applications of 4-aminopyrazolone derivatives as chromogenic agents for the spectrophotometric determination of phenols [J].
Fiamegos, YC ;
Stalikas, CD ;
Pilidis, GA ;
Karayannis, MI .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :315-323
[9]  
FIAMEGOS YC, UNPUB
[10]   Detector cell based on plastic liquid-core waveguides suitable for aqueous solutions: one-to-two decades improved detection limits in conventional-size column liquid chromatography with absorption detection [J].
Gooijer, C ;
Hoornweg, GP ;
de Beer, T ;
Bader, A ;
van Iperen, DJ ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1998, 824 (01) :1-5