Stress-based performance evaluation of osseointegrated dental implants by finite-element simulation

被引:63
作者
Baggi, Luigi [2 ]
Cappelloni, Ilaria [3 ]
Maceri, Franco [1 ]
Vairo, Giuseppe [1 ]
机构
[1] Univ Roma Tor Vergata, Dept Civil Engn, I-00133 Rome, Italy
[2] Univ Roma Tor Vergata, Sch Dent, I-00133 Rome, Italy
[3] Univ Roma Tor Vergata, Dept Mech Engn, I-00133 Rome, Italy
关键词
3D finite-element simulation; dental biomechanics; osseointegrated dental implants; platform switching influence; trabecular bone quality influence;
D O I
10.1016/j.simpat.2008.05.009
中图分类号
TP39 [计算机的应用];
学科分类号
081203 [计算机应用技术]; 0835 [软件工程];
摘要
In this paper biomechanical interaction between osseointegrated dental implants and bone is numerically investigated through 3D linearly elastic finite-element analyses, when static functional loads occur. Influence of some mechanical and geometrical parameters on bone stress distribution is highlighted and risk indicators relevant to critical overloading of bone are introduced. Insertions both in mandibular and maxillary molar segments are analyzed, taking into account different crestal bone loss configurations. Stress-based performances of five commercially-available dental implants are evaluated, demonstrating as the optimal choice of an endosseous implant is strongly affected by a number of shape parameters as well as by anatomy and mechanical properties of the site of placement. Moreover, effectiveness of some double-implant devices is addressed. The first one is relevant to a partially edentulous arch restoration, whereas other applications regard single-tooth restorations based on non-conventional endosteal mini-implants. Starting from computer tomography images and real devices, numerical models have been generated through a parametric algorithm based on a fully 3D approach. Furthermore, effectiveness and accuracy of finite-element simulations have been validated by means of a detailed convergence analysis. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:971 / 987
页数:17
相关论文
共 60 条
[1]
[Anonymous], 1999, CONTEMPORAY IMPLANT
[2]
ARKCA K, 2002, J DENT, V30, P40
[3]
Finite element analysis of stresses in endodontically treated, dowel-restored teeth [J].
Asmussen, E ;
Peutzfeldt, A ;
Sahafi, A .
JOURNAL OF PROSTHETIC DENTISTRY, 2005, 94 (04) :321-329
[4]
Effect of adhesive layer properties on stress distribution in composite restorations - a 3D finite element analysis [J].
Ausiello, P ;
Apicella, A ;
Davidson, CL .
DENTAL MATERIALS, 2002, 18 (04) :295-303
[5]
Implant-retained cantilever fixed prosthesis: Where and when [J].
Becker, CM ;
Kaiser, DA .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (04) :432-435
[6]
Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysis [J].
Bozkaya, D ;
Muftu, S ;
Muftu, A .
JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (06) :523-530
[7]
Bruce Martin R., 1998, Skeletal Tissue Mechanics
[8]
Brunski JB, 1997, IMPLANTS DENT ESSENT, P63
[9]
Callan D P, 1998, Implant Dent, V7, P258, DOI 10.1097/00008505-199807040-00003
[10]
Mechanical factors in bone growth and development [J].
Carter, DR ;
VanderMeulen, MCH ;
Beaupre, GS .
BONE, 1996, 18 (01) :S5-S10