Variations in the individual thick lamellar properties within osteons by nanoindentation

被引:179
作者
Rho, JY [1 ]
Zioupos, P
Currey, JD
Pharr, GM
机构
[1] Memphis State Univ, Dept Biomed Engn, Memphis, TN 38152 USA
[2] Cranfield Univ, Dept Mat & Med Sci, Shrivenham, England
[3] Univ York, Dept Biol, York, N Yorkshire, England
[4] Univ Tennessee, Dept Mat Sci, Knoxville, TN 37996 USA
[5] Oak Ridge Natl Lab, Div Met & Ceram, Oak Ridge, TN 37831 USA
基金
英国惠康基金;
关键词
elastic modulus; hardness; nanoindentation; osteons; lamellae of bone;
D O I
10.1016/S8756-3282(99)00163-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The nanoindentation method was used to examine variations in the individual thick lamellar properties within completed secondary osteons as a function of distance from the osteonal center (haversian canal). In general, there is a decline in both elastic modulus and hardness from the center of the osteon outward. Because some of the osteons may have a different general trend than others, an analysis of covariance was also carried out. The overall analysis was highly significant for both elastic modulus and hardness. Also, osteon number was significant as a factor, indicating that there was some difference in the overall thick lamellar properties of the different osteons, An unpaired t-test showed statistically significant differences (p = 0.0005 and 0.0004, respectively) between thick lamellar properties obtained from most of the inner two osteonal lamellae (E = 20.8 +/- 1.3 GPa and H = 0.65 +/- 0.06 GPa) and those from outermost two osteonal lamellae (E = 18.8 +/- 1.0 GPa and H = 0.55 +/- 0.05 GPa). In general, lamellar properties from near to the center of the osteon were greater than those from the outermost osteonal lamella. The mechanical properties of osteons are also significantly lower than those of the interstitial bone (p < 0.0001), The ratio (E-1/E-2) of the elastic moduli of the outermost osteonal lamella (E-1) (considered to be the soft part of the osteons) and that of interstitial bone (E-2) was approximately 0.7. These results may have important implications for the mechanical contribution of individual osteons to bone biomechanics. (C) 1999 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:295 / 300
页数:6
相关论文
共 31 条
[1]  
[Anonymous], 1905, ARCH ENT MECH ORG
[2]   THE TENSILE PROPERTIES OF SINGLE OSTEONIC LAMELLAE - TECHNICAL PROBLEMS AND PRELIMINARY-RESULTS [J].
ASCENZI, A ;
BENVENUTI, A ;
BONUCCI, E .
JOURNAL OF BIOMECHANICS, 1982, 15 (01) :29-37
[3]   MECHANICAL-PROPERTIES OF MICROCALLUS IN HUMAN CANCELLOUS BONE [J].
BLACKBURN, J ;
HODGSKINSON, R ;
CURREY, JD ;
MASON, JE .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (02) :237-246
[4]   COMPOSITION OF THE CEMENT LINE AND ITS POSSIBLE MECHANICAL ROLE AS A LOCAL INTERFACE INHUMAN COMPACT-BONE [J].
BURR, DB ;
SCHAFFLER, MB ;
FREDERICKSON, RG .
JOURNAL OF BIOMECHANICS, 1988, 21 (11) :939-&
[5]   AGING CHANGES IN OSTEON MINERALIZATION IN THE HUMAN FEMORAL-NECK [J].
CROFTS, RD ;
BOYCE, TM ;
BLOEBAUM, RD .
BONE, 1994, 15 (02) :147-152
[6]   A method for interpreting the data from depth-sensing indentation instruments [J].
Doerner, M. F. ;
Nix, W. D. .
JOURNAL OF MATERIALS RESEARCH, 1986, 1 (04) :601-609
[7]   Micromechanics of osteonal cortical bone fracture [J].
Guo, XE ;
Liang, LC ;
Goldstein, SA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (01) :112-117
[8]  
ISSONS HA, 1960, XRAY MICROSCOPY XRAY, P199
[9]   SCANNING ACOUSTIC MICROSCOPE STUDIES OF THE ELASTIC PROPERTIES OF OSTEONS AND OSTEON LAMALLAE [J].
KATZ, JL ;
MEUNIER, A .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :543-548
[10]  
MAROTTI G, 1994, ITAL J MINER ELECT M, V8, P167