Dynamic automated DNA hybridization on a CD (compact disc) fluidic platform

被引:39
作者
Jia, GY
Ma, KS
Kim, J
Zoval, JV
Peytavi, R
Bergeron, MG
Madou, MJ [1 ]
机构
[1] Univ Calif Irvine, Dept Mech & Aerosp Engn, Irvine, CA 92697 USA
[2] Univ Laval, Div Microbiol, Ste Foy, PQ G1V 4G2, Canada
[3] Univ Laval, Infect Dis Res Ctr, Ste Foy, PQ G1V 4G2, Canada
关键词
flow-through DNA hybridization; microfluidics; CD platform; centrifugal; 2-level SU-8 photolithography; ELF; 97;
D O I
10.1016/j.snb.2005.04.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A dynamic DNA hybridization microfluidic system was developed for a compact disc (CD) platform. The compact disc was used as the fluidic platform for sample and reagent manipulation using centrifugal force. Chambers for reagent storage and conduits for fluidic functions were replicated from polydimethylsiloxane (PDMS) using a SU-8 master mold fabricated by a 2-level lithography process which we developed specially for the microfluidic structures used in this work. For capture probes, we used self-assembled DNA oligonucleotide monolayers on gold pads patterned on glass slides. The PDMS flow cells were aligned with and sealed against the glass slides to form the DNA hybridization units. Hybridization was detected using an enzymatic-labeled fluorescence technique. An analytical model was introduced to quantitatively predict the accumulation of target DNA molecules. The flow-through hybridization units were tested using DNA samples (25-mers) of various concentrations down to 100 pM and passive assays (no flow) using samples of the same concentrations were performed for comparison. For the same concentration, with the same hybridization time (3 min), a fluorescence intensity increase up to threefold was observed in the flow-through hybridization unit compared to the passive hybridization assays. Furthermore, at the lowest sample concentration, the signal intensity from the passive assay is at the same level of the background while the signal from the flow-through assay is appreciably above the noise level. Besides the fast hybridization rate, the CD-based method has the potential for enabling highly automated, multiple and self-contained assays for DNA detection. (c) 2005 Elsevier B.V. All fights reserved.
引用
收藏
页码:173 / 181
页数:9
相关论文
共 40 条
[11]   Electric field directed nucleic acid hybridization on microchips [J].
Edman, CF ;
Raymond, DE ;
Wu, DJ ;
Tu, EG ;
Sosnowski, RG ;
Butler, WF ;
Nerenberg, M ;
Heller, MJ .
NUCLEIC ACIDS RESEARCH, 1997, 25 (24) :4907-4914
[12]   Modeling of DNA hybridization kinetics for spatially resolved biochips [J].
Erickson, D ;
Li, DQ ;
Krull, UJ .
ANALYTICAL BIOCHEMISTRY, 2003, 317 (02) :186-200
[13]   Dynamic DNA hybridization on a chip using paramagnetic beads [J].
Fan, ZH ;
Mangru, S ;
Granzow, R ;
Heaney, P ;
Ho, W ;
Dong, QP ;
Kumar, R .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4851-4859
[14]   MICROMACHINING OF CAPILLARY ELECTROPHORESIS INJECTORS AND SEPARATORS ON GLASS CHIPS AND EVALUATION OF FLOW AT CAPILLARY INTERSECTIONS [J].
FAN, ZH ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :177-184
[15]  
GEANKOPLIS CJ, 1972, MASS TRANSPORT PHENO, P135
[16]   Microchip device for performing enzyme assays [J].
Hadd, AG ;
Raymond, DE ;
Halliwell, JW ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3407-3412
[17]   Characterization of DNA probes immobilized on gold surfaces [J].
Herne, TM ;
Tarlov, MJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (38) :8916-8920
[18]   Poly(dimethylsiloxane) electrospray devices fabricated with diamond-like carbon-poly(dimethylsiloxane) coated SU-8 masters [J].
Huikko, K ;
Östman, P ;
Grigoras, K ;
Tuomikoski, S ;
Tiainen, VM ;
Soininen, A ;
Puolanne, K ;
Manz, A ;
Franssila, S ;
Kostiainen, R ;
Kotiaho, T .
LAB ON A CHIP, 2003, 3 (02) :67-72
[19]   Three-dimensional micro-channel fabrication in polydimethylsiloxane (PDMS) elastomer [J].
Jo, BH ;
Van Lerberghe, LM ;
Motsegood, KM ;
Beebe, DJ .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2000, 9 (01) :76-81
[20]   Development of a fully integrated analysis system for ions based on ion-selective optodes and centrifugal microfluidics [J].
Johnson, RD ;
Badr, IHA ;
Barrett, G ;
Lai, SY ;
Lu, YM ;
Madou, MJ ;
Bachas, LG .
ANALYTICAL CHEMISTRY, 2001, 73 (16) :3940-3946