Simulations of ion trapping in a micrometer-sized cylindrical ion trap

被引:18
作者
Austin, DE [1 ]
Cruz, D
Blain, MG
机构
[1] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
[2] Sandia Natl Labs, Albuquerque, NM 87185 USA
关键词
D O I
10.1016/j.jasms.2005.11.020
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have performed detailed SIMION simulations of ion behavior in micrometer-sized cylindrical ion traps (r(0) = 1 mu m). Simulations examined the effects of ion and neutral temperature, the pressure and nature of cooling gas, ion mass, trap voltage and frequency, space-charge, fabrication defects, and other parameters on the ability of micrometer-sized traps to store ions. At this size scale voltage and power limitations constrain trap operation to frequencies about 1 GHz and rf amplitudes of tens of volts. Correspondingly, the pseudopotential well depth of traps is shallow, and thermal energies contribute significantly to ion losses. Trapping efficiency falls off gradually as q(z) approaches 0.908, possibly complicating mass-selective trapping, ejection, or quantitation. Coulombic repulsion caused by multiple ions in a small-volume results in a trapping limit of a single ion per trap. If multiple ions are produced in a trap, all but one ion are ejected within a few microseconds. The remaining ion tends to have favorable trapping parameters and a lifetime about hundreds of microseconds; however, this lifetime is significantly shorter than it would have been in the absence of space-charge. Typical microfabrication defects affect ion trapping only minimally. We recently reported (IJMS 2004, 236, 91-104) on the construction of a massively parallel array of ion traps with dimensions of r(0) = 1 mu m. The relationship of the simulations to the expected performance of the microfabricated array is discussed.
引用
收藏
页码:430 / 441
页数:12
相关论文
共 48 条
[1]   Escape velocity and resonant ion dynamics in Paul trap mass spectrometers [J].
Abraham, GT ;
Chatterjee, A ;
Menon, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 231 (01) :1-16
[2]   A compact time-of-flight mass spectrometer for high-flux cosmic dust analysis [J].
Austin, DE ;
Beauchamp, JL ;
Manning, HLK ;
Bailey, CL .
JOURNAL OF GEOPHYSICAL RESEARCH-PLANETS, 2004, 109 (E7) :E07S071-5
[3]   Simulations of ion trapping in a micrometer-sized cylindrical ion trap [J].
Austin, DE ;
Cruz, D ;
Blain, MG .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (03) :430-441
[4]   Dustbuster:: a compact impact-ionization time-of-flight mass spectrometer for in situ analysis of cosmic dust [J].
Austin, DE ;
Ahrens, TJ ;
Beauchamp, JL .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (01) :185-189
[5]   Cylindrical ion trap array with mass selection by variation in trap dimensions [J].
Badman, ER ;
Cooks, RG .
ANALYTICAL CHEMISTRY, 2000, 72 (20) :5079-5086
[6]  
Badman ER, 2000, J MASS SPECTROM, V35, P659, DOI 10.1002/1096-9888(200006)35:6<659::AID-JMS5>3.0.CO
[7]  
2-V
[8]   A parallel miniature cylindrical ion trap array [J].
Badman, ER ;
Cooks, RG .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3291-3297
[9]   A miniature cylindrical quadrupole ion trap: Simulation and experiment [J].
Badman, ER ;
Johnson, RC ;
Plass, WR ;
Cooks, RG .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4896-4901
[10]   AN IMPROVED AND ACCURATE METHOD FOR THE CALCULATION OF TRAJECTORIES IN QUADRUPOLE MASS FILTERS AND ION TRAPS USING PHASE-SPACE DYNAMICS [J].
BARIL, M ;
LE, R ;
MARCHAND, P .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 98 (01) :87-97