Universal calibration for analysis of organic solutions of medium and low volatility by inductively coupled plasma-atomic emission spectrometry

被引:13
作者
Al-Ammar, AA [1 ]
Gupta, RK [1 ]
Barnes, RM [1 ]
机构
[1] Univ Massachusetts, Dept Chem, Amherst, MA 01003 USA
关键词
D O I
10.1039/a808389d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel chemometric technique is described to facilitate the use of a single organic solvent matrix standard to calibrate inductively coupled plasma atomic emission spectrometry (ICP-AES) for the accurate determination of trace elements in another organic solvent or complex mixture of several organic solvents. Analysis errors arising from the difference in solvent matrix vapor loading and chemical composition between standard and sample are corrected. The technique is intended for organic solvent mixtures for which the plasma vapor loading is tolerable with conventional sample introduction techniques (ic., conventional nebulizer-spray chamber arrangement without a solvent desolvator). Simultaneous measurement of atomic and ionic spectral lines of the same analyte is required. A correction factor is estimated from its linear correlation with the line intensity ratio. For elements without a sensitive atom line, the correction is estimated from the correlation between their ionic line intensities and the ratio of ionic-to-atomic line intensities of another analyte in the same sample. Experimental tests with seven trace elements (Al, Be, Ca, Cu, Fe, Mg, and Mn) in different organic solvent mixtures (xylene, dichloromethane, hexane, carbon disulfide, acetone and 1,2,3,4-tetrahydronaphthalene) demonstrate the effectiveness of universal calibration.
引用
收藏
页码:801 / 807
页数:7
相关论文
共 12 条
[1]  
Al-Ammar AS, 1998, ATOM SPECTROSC, V19, P18
[2]   Correction for non-spectroscopic matrix effects in inductively coupled plasma-atomic emission spectroscopy by internal standardization using spectral lines of the same analyte [J].
Al-Ammar, AS ;
Barnes, RM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (11) :1583-1593
[3]   CHARACTERIZATION AND OPTIMIZATION OF A DIRECT INJECTION NEBULIZER FOR INTRODUCTION OF ORGANIC-SOLVENTS AND VOLATILE ANALYTE SPECIES INTO AN INDUCTIVELY COUPLED PLASMA [J].
AVERY, TW ;
CHAKRABARTY, C ;
THOMPSON, JJ .
APPLIED SPECTROSCOPY, 1990, 44 (10) :1690-1698
[4]   EVAPORATION CHARACTERISTICS OF ORGANIC-SOLVENT AEROSOLS USED IN ANALYTICAL ATOMIC SPECTROMETRY [J].
BOORN, AW ;
CRESSER, MS ;
BROWNER, RF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1980, 35 (11-1) :823-832
[5]   Universal calibration for analysis of organic solutions by inductively coupled plasma atomic emission spectrometry [J].
Botto, RI ;
Zhu, JJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :675-681
[6]   USE OF AN ULTRASONIC NEBULIZER WITH MEMBRANE DESOLVATION FOR ANALYSIS OF VOLATILE SOLVENTS BY INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
BOTTO, RI ;
ZHU, JJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (09) :905-912
[7]   Determination of gold and platinum in the presence of blood plasma proteins using inductively coupled plasma mass spectrometry with direct injection nebulization [J].
Christodoulou, J ;
Kashani, M ;
Keohane, BM ;
Sadler, PJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (11) :1031-1035
[8]   A direct injection high-efficiency nebulizer for inductively coupled plasma mass spectrometry [J].
McLean, JA ;
Zhang, H ;
Montaser, A .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :1012-1020
[9]   REAL-TIME INTERNAL STANDARDIZATION FOR INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY USING A CUSTOM SEGMENTED-ARRAY CHARGE-COUPLED-DEVICE DETECTOR [J].
MERMET, JM ;
IVALDI, JC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (06) :795-801
[10]   Influence of the operating conditions on the efficiency of internal standardization in inductively coupled plasma atomic emission spectrometry [J].
Romero, X ;
Poussel, E ;
Mermet, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (04) :487-493