Single-Catheter Technique for Pulmonary Vein Antrum Isolation: Is It Sufficient to Identify and Close the Residual Gaps Without a Circular Mapping Catheter?

被引:40
作者
Dong, Jianzeng [1 ]
Liu, Xingpeng [1 ]
Long, Deyong [1 ]
Yu, Ronghui [1 ]
Tang, Ribo [1 ]
Lue, Fei [2 ]
Ma, Changsheng [1 ]
机构
[1] Capital Med Univ, Beijing Anzhen Hosp, Ctr Atrial Fibrillat, Dept Cardiol, Beijing 100029, Peoples R China
[2] Univ Minnesota, Sch Med, Cardiac Electrophysiol Serv, Dept Cardiovasc Med, Minneapolis, MN 55455 USA
基金
美国国家科学基金会;
关键词
atrial fibrillation; pulmonary vein; ablation; PAROXYSMAL ATRIAL-FIBRILLATION; DOUBLE-LASSO TECHNIQUE; ABLATION; EFFICACY; TACHYARRHYTHMIAS; LESSONS; ANATOMY; SAFETY;
D O I
10.1111/j.1540-8167.2008.01324.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Single Catheter for Pulmonary Vein Isolation. Objectives: The present study was designed to investigate the feasibility and efficacy of single ablation catheter for complete circumferential pulmonary vein antrum (PVA) isolation. Background: Complete isolation of pulmonary veins is the mainstay for atrial fibrillation (AF) ablation. This is usually performed under the guidance of a circular catheter. Methods: One hundred and ten consecutive patients with paroxysmal AF were prospectively randomized into two groups: single-catheter approach (group 1) and double-catheter approach (group 2). After performing initial circumferential lesions, residual gaps were mapped and closed with single ablation catheter in group 1 or guided by a circular mapping catheter in group 2 using an electroanatomic mapping system (CARTO (TM) XP, Biosense-Webster Inc., Diamond Bar, CA, USA). Results: Complete bilateral PVA isolation was achieved in 22 of the 110 patients after initial ablation. All residual gaps could be correctly identified by activation mapping using single ablation catheter. The distribution of these residual gaps was asymmetric. In group 1, 25 gaps along the right PVA lesions and 49 gaps along the left PVA lesions were identified. All the residual gaps were closed with single-catheter approach. In group 2, 28 gaps on the right side and 53 gaps on the left side were identified using a circular catheter and closed with further ablations. The procedure data and clinical outcomes between the two groups were comparable. Conclusions: Single ablation catheter technique is feasible and as effective as circular catheter mapping in localizing the residual gaps for PVA isolation during ablation of paroxysmal AF. (J Cardiovasc Electrophysiol, Vol. 20, pp. 273-279, March 2009).
引用
收藏
页码:273 / 279
页数:7
相关论文
共 22 条
[11]   Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation - Impact of different catheter technologies [J].
Marrouche, NF ;
Dresing, T ;
Cole, C ;
Bash, D ;
Saad, E ;
Balaban, K ;
Pavia, SV ;
Schweikert, R ;
Saliba, W ;
Abdul-Karim, A ;
Pisano, E ;
Fanelli, R ;
Tchou, P ;
Natale, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (03) :464-474
[12]   A new approach for catheter ablation of atrial fibrillation: Mapping of the electrophysiologic substrate [J].
Nademanee, K ;
McKenzie, J ;
Kosar, E ;
Schwab, M ;
Sunsaneewitayakul, B ;
Vasavakul, T ;
Khunnawat, C ;
Ngarmukos, T .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (11) :2044-2053
[13]   Venice chart international consensus document on atrial fibrillation ablation [J].
Natale, Andrea ;
Raviele, Antonio ;
Arentz, Thomas ;
Calkins, Hugh ;
Chen, Shih-Ann ;
Haissaguerre, Michel ;
Hindricks, Gerhard ;
Ho, Yen ;
Kuck, Karl Heinz ;
Marchlinski, Francis ;
Napolitano, Carlo ;
Packer, Douglas ;
Pappone, Carlo ;
Prystowsky, Eric N. ;
Schilling, Richard ;
Shah, Dipen ;
Themistoclakis, Sakis ;
Verma, Atul .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (05) :560-580
[14]   Catheter ablation for paroxysmal atrial fibrillation - Segmental pulmonary vein ostial ablation versus left atrial ablation [J].
Oral, H ;
Scharf, C ;
Chugh, A ;
Hall, B ;
Cheung, P ;
Good, E ;
Veerareddy, S ;
Pelosi, F ;
Morady, F .
CIRCULATION, 2003, 108 (19) :2355-2360
[15]   A tailored approach to catheter ablation of paroxysmal atrial fibrillation [J].
Oral, H ;
Chugh, A ;
Good, E ;
Sankaran, S ;
Reich, SS ;
Igic, P ;
Elmouchi, D ;
Tschopp, D ;
Crawford, T ;
Dey, S ;
Wimmer, A ;
Lemola, K ;
Jongnarangsin, K ;
Bogun, F ;
Pelosi, F ;
Morady, F .
CIRCULATION, 2006, 113 (15) :1824-1831
[16]   Prevalence of asymptomatic recurrences of atrial fibrillation after successful radiofrequency catheter ablation [J].
Oral, H ;
Veerareddy, S ;
Good, E ;
Hall, B ;
Cheung, P ;
Tamirisa, K ;
Han, J ;
Fortino, J ;
Chugh, A ;
Bogun, F ;
Pelosi, F ;
Morady, F .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (08) :920-924
[17]   Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins -: Lessons from double lasso technique [J].
Ouyang, FF ;
Antz, M ;
Ernst, S ;
Hachiya, H ;
Mavrakis, H ;
Deger, FT ;
Schaumann, A ;
Chun, J ;
Falk, P ;
Hennig, D ;
Liu, XP ;
Bänsch, D ;
Kuck, KH .
CIRCULATION, 2005, 111 (02) :127-135
[18]   Complete isolation of left atrium surrounding the pulmonary veins -: New insights from the double-lasso technique in paroxysmal atrial fibrillation [J].
Ouyang, FF ;
Bänsch, D ;
Ernst, S ;
Schaumann, A ;
Hachiya, H ;
Chen, ML ;
Chun, JL ;
Falk, P ;
Khanedani, A ;
Antz, M ;
Kuck, KH .
CIRCULATION, 2004, 110 (15) :2090-2096
[19]   Prevention of iatrogenic atrial tachycardia after ablation of atrial fibrillation - A prospective randomized study comparing circumferential pulmonary vein ablation with a modified approach [J].
Pappone, C ;
Manguso, F ;
Vicedomini, G ;
Gugliotta, F ;
Santinelli, O ;
Ferro, A ;
Gulletta, S ;
Sala, S ;
Sora, N ;
Paglino, G ;
Augello, G ;
Agricola, E ;
Zangrillo, A ;
Alfieri, O ;
Santinelli, V .
CIRCULATION, 2004, 110 (19) :3036-3042
[20]  
Pappone C, 2000, CIRCULATION, V102, P2619