Respiratory gating of cardiac PET data in list-mode acquisition

被引:67
作者
Livieratos, L
Rajappan, K
Stegger, L
Schafers, K
Bailey, DL
Camici, PG
机构
[1] Guys Hosp, Dept Nucl Med, London SE1 9RT, England
[2] Hammersmith Hosp, Imperial Coll, MRC, Clin Sci Ctr,PET Cardiol, London, England
[3] St Thomas Hosp, Dept Nucl Med, London SE1 9RT, England
[4] Munster Univ Hosp, Dept Nucl Med, Munster, Germany
[5] Royal N Shore Hosp, Dept Nucl Med, Sydney, NSW, Australia
基金
英国医学研究理事会;
关键词
respiratory gating; respiratory motion; PET;
D O I
10.1007/s00259-005-0031-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Respiratory motion has been identified as a source of artefacts in most medical imaging modalities. This paper reports on respiratory gating as a means to eliminate motion-related inaccuracies in PET imaging. Methods: Respiratory gating was implemented in list mode with physiological signal recorded every millisecond together with the PET data. Respiration was monitored with an inductive respiration monitor using an elasticised belt around the patient's chest. Simultaneous ECG gating can be maintained independently by encoding ECG trigger signal into the list-mode data. Respiratory gating is performed in an off-line workstation with gating parameters defined retrospectively. The technique was applied on a preliminary set of patient data with (CO)-O-15. Results: Motion was visually observed in the cine displays of the sagittal and coronal views of the reconstructed respiratory gated images. Significant changes in the cranial-caudal position of the heart could be observed. The centroid of the cardiac blood pool showed an excursion of 4.5-16.5 mm (mean 8.5 +/- 4.8 mm) in the cranial-caudal direction, with more limited excursion of 1.1-7.0 mm (mean 2.5 +/- 2.2 mm) in the horizontal direction and 1.3-3.7 mm (mean 2.4 +/- 0.9 mm) in the vertical direction. Conclusion: These preliminary data show that the extent of motion involved in respiration is comparable to myocardial wall thickness, and respiratory gating may be considered in order to reduce this effect in the reconstructed images.
引用
收藏
页码:584 / 588
页数:5
相关论文
共 18 条
  • [1] Experience with fully 3D PET and implications for future high-resolution 3D tomographs
    Bailey, DL
    Miller, MP
    Spinks, TJ
    Bloomfield, PM
    Livieratos, L
    Young, HE
    Jones, T
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04) : 777 - 786
  • [2] The design and implementation of a motion correction scheme for neurological PET
    Bloomfield, PM
    Spinks, TJ
    Reed, J
    Schnorr, L
    Westrip, AM
    Livieratos, L
    Fulton, R
    Jones, T
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (08) : 959 - 978
  • [3] Boucher L, 2004, J NUCL MED, V45, P214
  • [4] Development of respiratory gated myocardial SPECT system
    Cho, K
    Kumiata, S
    Okada, S
    Kumazaki, T
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (01) : 20 - 28
  • [5] PET-CT image co-registration in the thorax: influence of respiration
    Goerres, GW
    Kamel, E
    Heidelberg, TNH
    Schwitter, MR
    Burger, C
    von Schulthess, GK
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (03) : 351 - 360
  • [6] HOFFMAN EJ, 1979, J COMPUT ASSIST TOMO, V3, P733
  • [7] ANALYTIC 3D IMAGE-RECONSTRUCTION USING ALL DETECTED EVENTS
    KINAHAN, PE
    ROGERS, JG
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 964 - 968
  • [8] Non-rigid summing of gated PET via optical flow
    Klein, GJ
    Reutter, BW
    Huesman, RH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (04) : 1509 - 1512
  • [9] Real-time system for respiratory-cardiac gating in positron tomography
    Klein, GJ
    Reutter, BW
    Ho, MH
    Reed, JH
    Huesman, RH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (04) : 2139 - 2143
  • [10] RESPIRATORY KINEMATICS OF THE UPPER ABDOMINAL ORGANS - A QUANTITATIVE STUDY
    KORIN, HW
    EHMAN, RL
    RIEDERER, SJ
    FELMLEE, JP
    GRIMM, RC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) : 172 - 178