Prediction of pathological tumor volume in clinically localized prostate cancer: Value of endorectal coil magnetic resonance imaging

被引:23
作者
Lencioni, R
Menchi, I
Paolicchi, A
Carini, M
Amorosi, A
Bartolozzi, C
机构
[1] UNIV PISA,DEPT ONCOL,DIV RADIOL,I-56125 PISA,ITALY
[2] IPR RADIOL CTR,PRATO,ITALY
[3] UNIV FLORENCE,DIV UROL,FLORENCE,ITALY
[4] UNIV FLORENCE,DEPT PATHOL,FLORENCE,ITALY
关键词
magnetic resonance; surface coils; prostate; neoplasms;
D O I
10.1007/BF02592242
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to determine whether endorectal coil magnetic resonance imaging (MRI) enables accurate assessment of pathologic tumor volume in patients with clinically localized prostate carcinoma. Twenty-four patients with biopsy-proved prostate carcinoma underwent MRT at 0.5 T before radical prostatectomy. Tumor volumes were determined independently on axial fast-spin-echo (SE) T-2-weighted MR images and whole-mount pathology slides of the surgical specimens. At pathology, tumor volumes ranged from 0.17 to 9.42 cm(3) (mean +/- SD, 3.11 +/- 2.99 cm(3)). A strong correlation (r =.944) was found between measurements of tumor volume based on MR images and pathological specimens. The error was less than 0.5 cm(3) in 14 cases, in the range of 0.5-1 cm(3) in 7 cases, and more than 1 cm(3) in 3 cases. By using an MR tumor volume of 2 cm(3) as cutoff value, extracapsular tumor spread could be predicted with a sensitivity of 81.2%, a specificity of 100%, and an accuracy of 87.5%. Tumor volume determinations based on MR images seem to be accurate enough to be helpful in clinical decision-making.
引用
收藏
页码:117 / 121
页数:5
相关论文
共 35 条
  • [21] PROSTATE - MR IMAGING WITH AN ENDORECTAL SURFACE COIL
    SCHNALL, MD
    LENKINSKI, RE
    POLLACK, HM
    IMAI, Y
    KRESSEL, HY
    [J]. RADIOLOGY, 1989, 172 (02) : 570 - 574
  • [22] PROSTATE-CANCER - LOCAL STAGING WITH ENDORECTAL SURFACE COIL MR IMAGING
    SCHNALL, MD
    IMAI, Y
    TOMASZEWSKI, J
    POLLACK, HM
    LENKINSKI, RE
    KRESSEL, HY
    [J]. RADIOLOGY, 1991, 178 (03) : 797 - 802
  • [23] SILVERY E, 1990, CA-CANCER J CLIN, V40, P12
  • [24] DETERMINING THE VOLUME OF PROSTATIC-CARCINOMA - VALUE OF MR-IMAGING WITH AN EXTERNAL-ARRAY COIL
    SOMMER, FG
    NGHIEM, HV
    HERFKENS, R
    MCNEAL, J
    LOW, RN
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (01) : 81 - 86
  • [25] SPIGELMAN SS, 1986, J UROLOGY, V126, P1228
  • [26] STAMEY TA, 1988, J UROLOGY, V139, P1235
  • [27] STAMEY TA, 1993, CANCER, V71, P933, DOI 10.1002/1097-0142(19930201)71:3+<933::AID-CNCR2820711408>3.0.CO
  • [28] 2-L
  • [29] QUESTIONS REGARDING THE TREATMENT OF LOCALIZED PROSTATE-CANCER
    STEINFELD, AD
    [J]. RADIOLOGY, 1992, 184 (03) : 593 - 598
  • [30] STAGING OF PROSTATE-CANCER - RESULTS OF RADIOLOGY DIAGNOSTIC ONCOLOGY GROUP PROJECT COMPARISON OF 3 MR-IMAGING TECHNIQUES
    TEMPANY, CM
    ZHOU, X
    ZERHOUNI, EA
    RIFKIN, MD
    QUINT, LE
    PICCOLI, CW
    ELLIS, JH
    MCNEIL, BJ
    [J]. RADIOLOGY, 1994, 192 (01) : 47 - 54