Quantitative analysis of steroid hormones in human hair using a column-switching LC-APCI-MS/MS assay

被引:342
作者
Gao, Wei [1 ,2 ]
Stalder, Tobias [2 ]
Foley, Paul [2 ]
Rauh, Manfred [3 ]
Deng, Huihua [1 ]
Kirschbaum, Clemens [2 ]
机构
[1] Southeast Univ, Res Ctr Learning Sci, Nanjing 210096, Jiangsu, Peoples R China
[2] Tech Univ Dresden, Dept Psychol, D-01062 Dresden, Germany
[3] Univ Klinikum Erlangen, Kinder & Jugendklin, D-91054 Erlangen, Germany
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2013年 / 928卷
关键词
Steroid hormone; Hair; Mass spectrometry; Chromatography; On-line solid phase extraction; TANDEM MASS-SPECTROMETRY; ADRENAL-STEROIDS; CORTISOL; CORTICOSTEROIDS; QUANTIFICATION;
D O I
10.1016/j.jchromb.2013.03.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analysis of steroid hormones in hair is increasingly used in the field of stress-related research to obtain a retrospective index of integrated long-term hormone secretion. Here, most laboratories have so far relied on immunochemical assays originally developed for salivary analyses. Although these assays are fast and easy to perform, they have a reduced reliability and specificity due to cross-reactivity with other substances and are limited to the detection of one hormone at a time. Here, we report the development of a LC-MS/MS-based method for simultaneous identification of endogenous concentrations of seven steroid hormones (cortisol, cortisone, testosterone, progesterone, corticosterone, dehydroepiandrosterone (DHEA) and androstenedione) in human hair. Hair samples were washed with isopropanol and steroid hormones were extracted from 10 mg whole, nonpulverized hair by methanol incubation. A column switching strategy for on-line solid phase extraction (SPE) was applied, followed by analyte detection on an AB Sciex API5000 QTrap mass spectrometer. Results indicated linearity of the method for all steroids over ranges of 0.09-90 pg/mg (0.9-900 pg/mg for DHEA) with correlation coefficients ranging between 0.9995 and 0.9999. Intra- and inter-assay coefficients of variation were between 3.7 and 9.1%. The limits of quantification (LOQ) were below (or equal to) 0.1 pg/mg for all steroids, except of DHEA for which the LOQ was 0.9 pg/mg. An analysis of 30 natural hair samples (15 men/15 women) using this method confirmed that all steroid hormones could be quantified at endogenous levels in each individual. In addition, the use of whole hair samples and on-line SPE resulted in a significant reduction in sample throughput times, increasing the applicability of this method for research questions where a larger number of samples needs to be processed. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 19 条
[1]   Analysis of corticosteroids in hair by Liquid chromatography-electrospray ionization mass spectrometry [J].
Bévalot, F ;
Gaillard, Y ;
Lhermitte, MA ;
Pépin, G .
JOURNAL OF CHROMATOGRAPHY B, 2000, 740 (02) :227-236
[2]   Evaluation of neuroactive steroid levels by liquid chromatography-tandem mass spectrometry in central and peripheral nervous system: Effect of diabetes [J].
Caruso, Donatella ;
Scurati, Samuele ;
Maschi, Omar ;
De Angelis, Leonardo ;
Roglio, Ilaria ;
Giatti, Silvia ;
Garcia-Segura, Luis Miguel ;
Melcangi, Roberto C. .
NEUROCHEMISTRY INTERNATIONAL, 2008, 52 (4-5) :560-568
[3]   Simultaneous quantitation of seven endogenous C-21 adrenal steroids by liquid chromatography tandem mass spectrometry in human serum [J].
Carvalho, Valdemir Melechco ;
Nakamura, Odete Hirata ;
Henriques Vieira, Jose Gilberto .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 872 (1-2) :154-161
[4]   Automated Online Solid Phase Extraction Ultra High Performance Liquid Chromatography Method Coupled with Tandem Mass Spectrometry for Determination of Forty-Two Therapeutic Drugs and Drugs of Abuse in Human Urine [J].
Chiuminatto, Ugo ;
Gosetti, Fabio ;
Dossetto, Paolo ;
Mazzucco, Eleonora ;
Zampieri, Davide ;
Robotti, Elisa ;
Gennaro, Maria Carla ;
Marengo, Emilio .
ANALYTICAL CHEMISTRY, 2010, 82 (13) :5636-5645
[5]   GC-MS determination of steroids related to androgen biosynthesis in human hair with pentafluorophenyldimethylsilyl-trimethylsilyl derivatisation [J].
Choi, MH ;
Chung, BC .
ANALYST, 1999, 124 (09) :1297-1300
[6]   Identification of ten corticosteroids in human hair by liquid chromatography-ionspray mass spectrometry [J].
Cirimele, V ;
Kintz, P ;
Dumestre, V ;
Goullé, JP ;
Ludes, B .
FORENSIC SCIENCE INTERNATIONAL, 2000, 107 (1-3) :381-388
[7]   A generic fast solid-phase extraction high-performance liquid chromatography/mass spectrometry method for high-throughput drug discovery [J].
Gao, Lan ;
Cheng, Xueheng ;
Zhang, Jun ;
Burns, David J. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (21) :3497-3504
[8]   Quantitative measurements of corticosteroids in ex vivo samples using on-line SPE-LC/MS/MS [J].
Gao, Lan ;
Chiou, William J. ;
Camp, Heidi S. ;
Burns, David J. ;
Cheng, Xueheng .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (03) :303-310
[9]   HPLC-FLU detection of cortisol distribution in human hair [J].
Gao, Wei ;
Xie, Qiaozhen ;
Jin, Jing ;
Qiao, Ting ;
Wang, Haiyang ;
Chen, Liqin ;
Deng, Huihua ;
Lu, Zuhong .
CLINICAL BIOCHEMISTRY, 2010, 43 (7-8) :677-682
[10]   Simultaneous determination of 12 steroids by isotope dilution liquid chromatography-photo spray ionization tandem mass spectrometry [J].
Guo, Tiedong ;
Taylor, Robert L. ;
Singh, Ravinder J. ;
Soldin, Steven J. .
CLINICA CHIMICA ACTA, 2006, 372 (1-2) :76-82