Research on low-order current harmonics rejections for grid-connected LCL-filtered inverters

被引:32
作者
Xu, Jinming [1 ]
Tang, Ting [1 ]
Xie, Shaojun [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Nanjing 210016, Peoples R China
基金
中央高校基本科研业务费专项资金资助; 中国国家自然科学基金;
关键词
electric current control; feedforward; harmonic distortion; invertors; power grids; power harmonic filters; power system interconnection; voltage control; LC circuits; current harmonics rejection; grid connected LCL filtered inverter; current quality; grid voltage distortion; dead time effect; nonideal switch; DC link disturbance; injected grid current; harmonic resonant control; multiharmonic source impact rejection; grid voltage feedforward control; multiHR control; harmonics suppression; DESIGN; VOLTAGE;
D O I
10.1049/iet-pel.2013.0477
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The current quality is an important indicator to evaluate the performance of a grid-connected inverter. In practice, many factors including the grid voltage distortion, dead-time effect, non-ideal switches and dc-link disturbances would result in many low-order harmonics in the injected grid current. The inverter with either the typical grid voltage feedforward or the harmonic resonant (HR) control had some difficulties in rejecting the impact of multi-harmonic sources. In this study, the combination of the grid voltage feedforward and the multi-HR control is proposed to suppress low-order harmonics. It is found that all those harmonic sources are classified into two kinds, and a general way is provided to analyse the harmonic rejection of the inverter with the typical or the proposed strategy. The low-order current harmonics of the inverter with different strategies are clearly explained. The comparative analysis, simulations and experiments all indicate that the proposed strategy greatly improves the ability of the inverter to reject the current harmonics induced by multi-harmonic sources as long as the grid feedforward and the resonant control are complementary.
引用
收藏
页码:1227 / 1234
页数:8
相关论文
共 16 条
[1]   Overview of control and grid synchronization for distributed power generation systems [J].
Blaabjerg, Frede ;
Teodorescu, Remus ;
Liserre, Marco ;
Timbus, Adrian V. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) :1398-1409
[2]   Control Design Guidelines for Single-Phase Grid-Connected Photovoltaic Inverters With Damped Resonant Harmonic Compensators [J].
Castilla, Miguel ;
Miret, Jaume ;
Matas, Jose ;
Garcia de Vicuna, Luis ;
Guerrero, Josep M. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (11) :4492-4501
[3]   Investigation of Active Damping Approaches for PI-Based Current Control of Grid-Connected Pulse Width Modulation Converters With LCL Filters [J].
Dannehl, Joerg ;
Fuchs, Friedrich Wilhelm ;
Hansen, Steffan ;
Thogersen, Paul Bach .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (04) :1509-1517
[4]   Inverter nonlinearity effects in hign-frequency signal-injection-based sensorless control methods [J].
Guerrero, JM ;
Leetmaa, M ;
Briz, F ;
Zamarrón, A ;
Lorenz, RD .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (02) :618-626
[5]   Robust proportional resonant regulator for grid-connected voltage source inverter (VSI) using direct pole placement design method [J].
Li, B. ;
Yao, W. ;
Hang, L. ;
Tolbert, L. M. .
IET POWER ELECTRONICS, 2012, 5 (08) :1367-1373
[6]   Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values [J].
Liserre, M ;
Teodorescu, R ;
Blaabjerg, F .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2006, 21 (01) :263-272
[7]   Design and control of an LCL-filter-based three-phase active rectifier [J].
Liserre, M ;
Blaabjerg, F ;
Hansen, S .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (05) :1281-1291
[8]   Parameter Design of a Two-Current-Loop Controller Used in a Grid-Connected Inverter System With LCL Filter [J].
Liu, Fei ;
Zhou, Yan ;
Duan, Shanxu ;
Yin, Jinjun ;
Liu, Bangyin ;
Liu, Fangrui .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (11) :4483-4491
[9]   Analysis of a hybrid controlled three-phase grid-connected inverter with harmonics compensation in synchronous reference frame [J].
Sha, D. ;
Wu, D. ;
Liao, X. .
IET POWER ELECTRONICS, 2011, 4 (07) :743-751
[10]   A New Feedback Method for PR Current Control of LCL-Filter-Based Grid-Connected Inverter [J].
Shen, Guoqiao ;
Zhu, Xuancai ;
Zhang, Jun ;
Xu, Dehong .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (06) :2033-2041