Immunoassays based on microelectrodes arrayed on a silicon chip for high throughput screening of liver fibrosis markers in human serum

被引:31
作者
Shi, Mianhong
Peng, Youyuan
Zhou, Jia
Liu, Baohong
Huang, Yipin
Kong, Jilie [1 ]
机构
[1] Fudan Univ, Dept Chem, Shanghai 200433, Peoples R China
[2] Fudan Univ, Inst Microelect, Shanghai 200433, Peoples R China
基金
中国国家自然科学基金;
关键词
immunoassay; disease markers; micorchip; cyclic voltammetry;
D O I
10.1016/j.bios.2005.11.011
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel immunoassays for screening of disease markers in human serum are presented by miniaturizing interdigitated array (IDA) of microelectrodes via micro electro-mechanical system (MEMS) on a silicon chip for multi-channel electrochemical measurement. Different selected antibodies (Abs) are incorporated site-specifically into the electrochemically deposited polypyrrole (PPy) formed on the IDA of the silicon chip, which was characterized by fluorescence microscope photo and the electrochemical quartz crystal microbalance (EQCM) measurements. The selective recognition of Ab to the corresponding antigen (Ag) is monitored through the measurable conductivity change, which is directly visualized by cyclic voltammograms (CVs) in presence of the redox probe, Fe (CN)(6)(3-/4-). By using the strategy presented here, three liver fibrosis markers, hyaluronic acid (HA), lamin (LN) and collagen type IV (IV-C), are detected simultaneously and specifically at the surface of the chip with calibration curves, y = 21.75 + 0.84x (R = 0.995), y = 57.54 + 0.47x (R = 0.999) and y = 37.92 + 0.28x (R = 0.999), separately. Either the standard or the serum samples can be detected at ng/mL concentration level in a tiny amount of volume, similar to 50 mu L. The chip-based immunoassay shows the advantages of high sensitivity, good specificity, high throughput, low sample consumption, and the stability offered via batch production by MEMS as well, which is expected to benefit the multi-target screening of desired clinical analytes. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:2210 / 2216
页数:7
相关论文
共 33 条
[1]   Characterisation and analytical use of a polypyrrole electrode containing anti-human serum albumin [J].
Barisci, JN ;
Hughes, D ;
Minett, A ;
Wallace, GG .
ANALYTICA CHIMICA ACTA, 1998, 371 (01) :39-48
[2]   ELECTROCHEMICAL DOPING OF POLYPYRROLE - XPS STUDY [J].
BEELEN, E ;
RIGA, J ;
VERBIST, JJ .
SYNTHETIC METALS, 1991, 41 (1-2) :449-454
[3]  
BRUYNE AD, 1997, J APPL ELECTROCHEM, V27, P867
[4]   Application of a 32-microband electrode array detection system for liquid chromatography analysis [J].
Chao, MH ;
Huang, HJ .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :463-470
[5]   MECHANICAL-PROPERTIES OF ELECTROCHEMICALLY PREPARED POLYPYRROLE FILMS [J].
DIAZ, AF ;
HALL, B .
IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 1983, 27 (04) :342-347
[6]   Continuous separations with microfabricated electrophoresis-electrochemical array detection [J].
Gavin, PF ;
Ewing, AG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (37) :8932-8936
[7]   Permeability enhancement of electropolymerized thin organic films [J].
Gros, P ;
Gibson, T ;
Bergel, A ;
Comtat, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 437 (1-2) :125-134
[8]  
Habermüller K, 1998, ELECTROANAL, V10, P1281, DOI 10.1002/(SICI)1521-4109(199812)10:18<1281::AID-ELAN1281>3.0.CO
[9]  
2-I
[10]   Ultrathin alumina sol-gel-derived films: Allowing direct detection of the liver fibrosis markers by capacitance measurement [J].
Jiang, DC ;
Tang, J ;
Liu, BH ;
Yang, PY ;
Kong, JL .
ANALYTICAL CHEMISTRY, 2003, 75 (17) :4578-4584