摘要
Three-dimensional (3-D) angiographic methods are gaining acceptance for evaluation of atherosclerotic disease. However, measurement of vessel stenosis from 3-D angiographic methods can be problematic due to limited image resolution and contrast. We present a method for reconstructing vessel surfaces from 3-D angiographic methods that allows for objective measurement of vessel stenosis. The method is a deformable model that employs a tubular coordinate system. Vertex merging is incorporated into the coordinate system to maintain even vertex spacing and to avoid problems of self-intersection of the surface. The deformable model was evaluated on clinical magnetic resonance (MR) images of the carotid (n = 6) and renal (n = 2) arteries, on an MR image of a physical vascular phantom and on a digital vascular phantom. Only one gross error occurred for all clinical images. All reconstructed surfaces had a realistic, smooth appearance. For all segments of the physical vascular phantom, vessel radii from the surface reconstruction had an error of less than 0.2 of the average voxel dimension. Variability of manual initialization of the deformable model had negligible effect on the measurement of the degree of stenosis of the digital vascular phantom.
引用
收藏
页码:1411 / 1421
页数:11
相关论文
共 31 条
[1]   Volumetric assessment of carotid artery bifurcation using freehand-acquired, compound 3D ultrasound [J].
Allott, CP ;
Barry, CD ;
Pickford, R ;
Waterton, JC .
BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (855) :289-292
[2]  
AYLWARD S, 1996, IEEE WORKSH MATH MET
[4]   Spiral CT of abdominal aortic aneurysms: Comparison of segmentation with an automatic 3D deformable model and interactive segmentation [J].
Bulpitt, AJ ;
Berry, E .
MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 :938-946
[5]   Merging of intersecting triangulations for finite element modeling [J].
Cebral, JR ;
Löhner, R ;
Choyke, PL ;
Yim, PJ .
JOURNAL OF BIOMECHANICS, 2001, 34 (06) :815-819
[6]  
CEBRAL JR, 1999, P 8 INT MESH ROUNDT, P321
[7]   Improved imaging of carotid artery bifurcation using helical computed tomographic angiography [J].
Cinat, ME ;
Pham, H ;
Vo, D ;
Gordon, I ;
Wilson, SE .
ANNALS OF VASCULAR SURGERY, 1999, 13 (02) :178-183
[8]   3D SURFACE RENDERED MR IMAGES OF THE BRAIN AND ITS VASCULATURE [J].
CLINE, HE ;
LORENSEN, WE ;
SOUZA, SP ;
JOLESZ, FA ;
KIKINIS, R ;
GERIG, G ;
KENNEDY, TE .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (02) :344-351
[9]  
Foo TKF, 1999, NEUROIMAG CLIN N AM, V9, P263
[10]   Model-based quantitation of 3-D magnetic resonance angiographic images [J].
Frangi, AF ;
Niessen, WJ ;
Hoogeveen, RM ;
van Walsum, T ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (10) :946-956