Further application of a procedure for molecular weight and molecular weight distribution measurement of polydisperse polymers from their matrix-assisted laser desorption/ionization time-of-flight mass spectra

被引:52
作者
Vitalini, D [1 ]
Mineo, P [1 ]
Scamporrino, E [1 ]
机构
[1] UNIV CATANIA,DIPARTIMENTO SCI CHIM,I-95125 CATANIA,ITALY
关键词
D O I
10.1021/ma9702206
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
A recently reported off-line procedure to estimate molecular weight (MW) averages and molecular weight distribution (MWD) index, also for polydisperse polymers, directly from their matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectra was applied here to poly(bisphenol A-carbonate) (PC), a poly(ether-sulfone) resin (PES), and poly(dimethylphenylene oxide) (PDMPO), all having a wide polydispersity index. The MW and MWD obtained Values were compared with those determined by GPC or supplied by makers. A structural characterization of these polymers was also performed by examining their MALDI-TOF mass spectra.
引用
收藏
页码:5285 / 5289
页数:5
相关论文
共 37 条
[11]  
DANIS PO, 1996, POLYM PREPR, V36, P311
[12]  
Garozzo D, 1995, RAPID COMMUN MASS SP, V9, P937
[13]   IMPROVEMENT OF SIGNAL REPRODUCIBILITY AND MATRIX/COMATRIX EFFECTS IN MALDI ANALYSIS [J].
GUSEV, AI ;
WILKINSON, WR ;
PROCTOR, A ;
HERCULES, DM .
ANALYTICAL CHEMISTRY, 1995, 67 (06) :1034-1041
[14]  
HILLENKAMP F, 1991, ANAL CHEM, V63, pA1193
[15]   Comparison of most probable peak values as measured for polymer distributions by MALDI mass spectrometry and by size exclusion chromatography [J].
Jackson, C ;
Larsen, B ;
McEwen, C .
ANALYTICAL CHEMISTRY, 1996, 68 (08) :1303-1308
[16]   LASER DESORPTION IONIZATION OF PROTEINS WITH MOLECULAR MASSES EXCEEDING 10000 DALTONS [J].
KARAS, M ;
HILLENKAMP, F .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2299-2301
[17]   POLYMER MOLECULAR-WEIGHT DISTRIBUTION - RESULTS FROM MATRIX-ASSISTED LASER-DESORPTION IONIZATION COMPARED WITH THOSE FROM GEL-PERMEATION CHROMATOGRAPHY [J].
LEHRLE, RS ;
SARSON, DS .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (01) :91-92
[18]   Degradation and selective desorption of polymer can cause uncertainty in MALDI (matrix-assisted laser desorption ionisation) measurements [J].
Lehrle, RS ;
Sarson, DS .
POLYMER DEGRADATION AND STABILITY, 1996, 51 (02) :197-204
[19]   A COMPARISON BETWEEN MATRIX-ASSISTED LASER-DESORPTION IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY AND SIZE-EXCLUSION CHROMATOGRAPHY IN THE MASS CHARACTERIZATION OF SYNTHETIC-POLYMERS WITH NARROW MOLECULAR-MASS DISTRIBUTIONS - POLY(METHYL METHACRYLATE) AND POLY(STYRENE) [J].
LLOYD, PM ;
SUDDABY, KG ;
VARNEY, JE ;
SCRIVENER, E ;
DERRICK, PJ ;
HADDLETON, DM .
EUROPEAN MASS SPECTROMETRY, 1995, 1 (03) :293-300
[20]   POLYMETHYLMETHACRYLATE END-GROUP ANALYSIS BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY (MALDI-TOF-MS) [J].
MALONEY, DR ;
HUNT, KH ;
LLOYD, PM ;
MUIR, AVG ;
RICHARDS, SN ;
DERRICK, PJ ;
HADDLETON, DM .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1995, (05) :561-562