Review of the assessment of single level and multilevel arterial occlusive disease in lower limbs by duplex ultrasound

被引:22
作者
Allard, L
Cloutier, G
Guo, ZY
Durand, LG
机构
[1] Inst Rech Clin Montreal, Lab Gen Biomed, Montreal, PQ H2W 1R7, Canada
[2] Univ Montreal, Dept Med, Montreal, PQ, Canada
[3] George Washington Univ, Dept Elect Engn, Washington, DC USA
基金
英国医学研究理事会;
关键词
Doppler ultrasound; power mode; arterial occlusive disease; stenosis; review;
D O I
10.1016/S0301-5629(98)00130-6
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of this article is to review the performance of duplex ultrasound scanning in assessing lower limb arterial disease with emphasis on patients with multisegmental occlusive lesions. Several studies have reported that duplex scanning can be as accurate as angiography to localize arterial stenoses, In spite of these promising results, there still remain some difficulties and controversies. Among them, it has been reported that multisegmental disease may affect the accuracy of duplex scanning. Indeed, some studies have indicated a lower sensitivity for detecting significant stenoses distal to severe or total occlusions. It also was demonstrated that second-order stenoses were detected with lower sensitivity compared to first-order stenoses, The main reason proposed to explain this lower sensitivity is that the highly reduced flow distal to occluded or highly stenotic segments increases the difficulty of detecting significant Doppler velocity changes in the distal or secondary stenoses, The intrinsic limitations of the peak systolic velocity ratio used as a classification criterion are presented. Finally, new and promising developments in power Doppler imaging and ultrasound contrast agents are discussed, because they may allow expansion of the capabilities of current ultrasound scanning systems and provide more accurate diagnosis of patients with multiple disease, (C) 1999 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:495 / 502
页数:8
相关论文
共 57 条
[1]   DOPPLER VELOCITY RATIO MEASUREMENTS EVALUATED IN A PHANTOM MODEL OF MULTIPLE ARTERIAL-DISEASE [J].
ALLARD, L ;
CLOUTIER, G ;
DURAND, LG .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (04) :471-480
[2]   LIMITATIONS OF ULTRASONIC DUPLEX SCANNING FOR DIAGNOSING LOWER-LIMB ARTERIAL STENOSES IN THE PRESENCE OF ADJACENT SEGMENT DISEASE [J].
ALLARD, L ;
CLOUTIER, G ;
DURAND, LG ;
ROEDERER, GO ;
LANGLOIS, YE .
JOURNAL OF VASCULAR SURGERY, 1994, 19 (04) :650-657
[3]   COMPUTER-ANALYSIS AND PATTERN-RECOGNITION OF DOPPLER BLOOD-FLOW SPECTRA FOR DISEASE CLASSIFICATION IN THE LOWER-LIMB ARTERIES [J].
ALLARD, L ;
LANGLOIS, YE ;
DURAND, LG ;
ROEDERER, GO ;
BEAUDOIN, M ;
CLOUTIER, G ;
ROY, P ;
ROBILLARD, P .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (03) :211-223
[4]   EFFECT OF MULTILEVEL SEQUENTIAL STENOSIS ON LOWER-EXTREMITY ARTERIAL DUPLEX SCANNING [J].
BERGAMINI, TM ;
TATUM, CM ;
MARSHALL, C ;
HALLDISSELKAMP, B ;
RICHARDSON, JD .
AMERICAN JOURNAL OF SURGERY, 1995, 169 (06) :564-566
[5]  
BERRITT CRB, 1987, J CLIN ULTRASOUND, V15, P591
[6]   Aorto-iliac reconstruction without arteriography [J].
Bodily, K ;
Buttorff, J ;
Nordesgaard, A ;
Osborne, R .
AMERICAN JOURNAL OF SURGERY, 1996, 171 (05) :505-507
[7]   COMPARISON OF CONTRAST ARTERIOGRAPHY TO ARTERIAL MAPPING WITH COLOR-FLOW DUPLEX IMAGING IN THE LOWER-EXTREMITIES [J].
COSSMAN, DV ;
ELLISON, JE ;
WAGNER, WH ;
CARROLL, RM ;
TREIMAN, RL ;
FORAN, RF ;
LEVIN, PM ;
COHEN, JL .
JOURNAL OF VASCULAR SURGERY, 1989, 10 (05) :522-529
[8]   Duplex velocity characteristics of aortoiliac stenoses [J].
deSmet, AAEA ;
Ermers, EJM ;
Kitslaar, PJEHM .
JOURNAL OF VASCULAR SURGERY, 1996, 23 (04) :628-636
[9]  
EDWARDS JM, 1991, J VASC SURG, V13, P69
[10]  
Elsman BH, 1996, CARDIOVASC INTER RAD, V19, P313