A Bayesian Approach for Quantifying Trace Amounts of Antibody Aggregates by Sedimentation Velocity Analytical Ultracentrifugation

被引:27
作者
Brown, Patrick H. [1 ]
Balbo, Andrea [1 ]
Schuck, Peter [1 ]
机构
[1] Natl Inst Biomed Imaging & Bioengn, Dynam Macromol Assembly Sect, Lab Bioengn & Phys Sci, NIH, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
analytical ultracentrifugation; Bayesian analysis; hydrodynamic separation; sedimentation velocity; size-distribution; trace aggregates;
D O I
10.1208/s12248-008-9058-z
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Sedimentation velocity analytical ultracentrifugation (SV-AUC) has become an important tool for the characterization of the purity of protein therapeutics. The work presented here addresses a need for methods orthogonal to size-exclusion chromatography for ensuring the reliable quantitation of immunogenic oligomers, for example, in antibody preparations. Currently the most commonly used approach for SV-AUC analysis is the diffusion-deconvoluted sedimentation coefficient distribution c(s) method, previously developed by us as a general purpose technique and implemented in the software SEDFIT. In both practical and theoretical studies, different groups have reported a sensitivity of c(s) for trace oligomeric fractions well below the 1% level. In the present work we present a variant of c(s) designed for the purpose of trace detection, with customized Bayesian regularization. The original c(s) method relies on maximum entropy regularization providing the most parsimonious distribution consistent with the data. In the present paper, we use computer simulations of an antibody system as example to demonstrate that the standard maximum entropy regularization, due to its design, leads to a theoretical lower limit for the detection of oligomeric traces and a consistent underestimate of the trace populations by -0.1% (dependent on the level of regularization). This can be overcome with a recently developed Bayesian extension of c(s) (Brown et al., Biomacromolecules, 8:2011-2024, 2007), utilizing the known regions of sedimentation coefficients for the monomer and oligomers of interest as prior expectation for the peak positions in the distribution. We show that this leads to more clearly identifiable and consistent peaks and lower theoretical limits of quantization by approximately an order of magnitude for some experimental conditions. Implications for the experimental design of SV-AUC and practical detection limits are discussed.
引用
收藏
页码:481 / 493
页数:13
相关论文
共 36 条
[1]   Role of analytical ultracentrifugation in assessing the aggregation of protein biopharmaceuticals [J].
Berkowitz, Steven A. .
AAPS JOURNAL, 2006, 8 (03) :E590-E605
[2]   A new adaptive grid-size algorithm for the simulation of sedimentation velocity profiles in analytical ultracentrifugation [J].
Brown, Patrick H. ;
Schuck, Peter .
COMPUTER PHYSICS COMMUNICATIONS, 2008, 178 (02) :105-120
[3]   Using prior knowledge in the determination of macromolecular size-distributions by analytical ultracentrifugation [J].
Brown, Patrick H. ;
Balbo, Andrea ;
Schuck, Peter .
BIOMACROMOLECULES, 2007, 8 (06) :2011-2024
[4]   Characterizing biological products and assessing comparability following manufacturing changes [J].
Chirino, AJ ;
Mire-Sluis, A .
NATURE BIOTECHNOLOGY, 2004, 22 (11) :1383-1391
[5]  
CLELAND JL, 1993, CRIT REV THER DRUG, V10, P307
[6]   Protein aggregation and bioprocessing [J].
Cromwell, Mary E. M. ;
Hilario, Eric ;
Jacobson, Fred .
AAPS JOURNAL, 2006, 8 (03) :E572-E579
[7]  
Dam J, 2004, METHOD ENZYMOL, V384, P185
[8]   The use of asymmetrical flow field-flow fractionation in pharmaceutics and biopharmaceutics [J].
Fraunhofer, W ;
Winter, G .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2004, 58 (02) :369-383
[9]   Quantitation of aggregate levels in a recombinant humanized monoclonal antibody formulation by size-exclusion chromatography, asymmetrical flow field flow fractionation, and sedimentation velocity [J].
Gabrielson, John P. ;
Brader, Mark L. ;
Pekar, Allen H. ;
Mathis, Kathrin B. ;
Winter, Gerhard ;
Carpenter, John F. ;
Randolph, Theodore W. .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2007, 96 (02) :268-279
[10]   Sedimentation velocity analytical ultracentrifugation and SEDFIT/c(s):: Limits of quantitation for a monoclonal antibody system [J].
Gabrielson, John P. ;
Randolph, Theodore W. ;
Kendrick, Brent S. ;
Stoner, Michael R. .
ANALYTICAL BIOCHEMISTRY, 2007, 361 (01) :24-30