Unsatisfactory Accuracy as Determined by Computer Navigation of VISIONAIRE Patient-Specific Instrumentation for Total Knee Arthroplasty

被引:79
作者
Lustig, Sebastien [1 ,2 ]
Scholes, Corey J. [1 ]
Oussedik, Sam I. [1 ]
Kinzel, Vera [1 ]
Coolican, Myles R. J. [1 ]
Parker, David A. [1 ]
机构
[1] Sydney Orthopaed Res Inst, Chatswood, NSW, Australia
[2] Lyon Univ Hosp, Albert Trillat Ctr, Lyon, France
关键词
total knee arthroplasty; patient-specific instrumentation; navigation; accuracy; CORONAL ALIGNMENT; TIBIAL ALIGNMENT; REPLACEMENT; METAANALYSIS;
D O I
10.1016/j.arth.2012.07.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
This investigation evaluated the Smith and Nephew VISIONAIRE patient-specific cutting block (PSCB) system for total knee arthroplasty. A consecutive series of 60 patients was recruited. Intraoperative computer navigation was used to evaluate the accuracy of the cutting blocks in the coronal and sagittal planes for the tibia, as well as rotational plane for the femur. The PSCB would have placed 79.3% of the sample within +/- 3 degrees of the preoperative plan in the coronal plane, while the rotational and sagittal alignment results within +/- 3 degrees were 77.2% and 54.5% respectively. The VISIONAIRE PSCB system achieved unacceptable accuracy when assessed by computer navigation. There might be many sources of error, but caution is recommended before using this system routinely without objective verification of alignment. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:469 / 473
页数:5
相关论文
共 29 条
[1]
Custom-Fit Total Knee Arthroplasty: Our Initial Experience in 32 Knees [J].
Bali, Kamal ;
Walker, Peter ;
Bruce, Warwick .
JOURNAL OF ARTHROPLASTY, 2012, 27 (06) :1149-1154
[2]
Are MRI-based, patient matched cutting jigs as accurate as the tibial guides? [J].
Conteduca, Fabio ;
Iorio, Raffaele ;
Mazza, Daniele ;
Caperna, Ludovico ;
Bolle, Gabriele ;
Argento, Giuseppe ;
Ferretti, Andrea .
INTERNATIONAL ORTHOPAEDICS, 2012, 36 (08) :1589-1593
[3]
Instability in Primary Total Knee Arthroplasty [J].
Del Gaizo, Daniel J. ;
Della Valle, Craig J. .
ORTHOPEDICS, 2011, 34 (09) :E519-E521
[4]
Dennis D A, 1993, J Arthroplasty, V8, P43, DOI 10.1016/S0883-5403(06)80106-3
[5]
Doro Lisa Case, 2008, Open Biomed Eng J, V2, P52, DOI 10.2174/1874120700802010052
[6]
Engh G A, 1990, J Arthroplasty, V5, P1, DOI 10.1016/S0883-5403(06)80002-1
[7]
Coronal Alignment in Total Knee Arthroplasty Just How Important is it? [J].
Fang, David M. ;
Ritter, Merrill A. ;
Davis, Kenneth E. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (06) :39-43
[8]
The effects of varus tibial alignment on proximal tibial surface strain in total knee arthroplasty - The posteromedial hot spot [J].
Green, GV ;
Berend, KR ;
Berend, ME ;
Glisson, RR ;
Vail, TP .
JOURNAL OF ARTHROPLASTY, 2002, 17 (08) :1033-1039
[9]
The Geometry of the Tibial Plateau and Its Influence on the Biomechanics of the Tibiofemoral Joint [J].
Hashemi, Javad ;
Chandrashekar, Naveen ;
Gill, Brian ;
Beynnon, Bruce D. ;
Slauterbeck, James R. ;
Schutt, Robert C., Jr. ;
Mansouri, Hossein ;
Dabezies, Eugene .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (12) :2724-2734
[10]
Meta-Analysis of Navigation vs Conventional Total Knee Arthroplasty [J].
Hetaimish, Bandar M. ;
Khan, M. Moin ;
Simunovic, Nicole ;
Al-Harhi, Hatem H. ;
Bhandari, Mohit ;
Zalzal, Paul K. .
JOURNAL OF ARTHROPLASTY, 2012, 27 (06) :1177-1182