Less range of motion with resurfacing arthroplasty than with total hip arthroplasty In vitro examination of 8 designs

被引:29
作者
Bengs, Benjamin C. [2 ]
Sangiorgio, Sophia N. [1 ]
Ebramzadeh, Edward [1 ]
机构
[1] Angeles Orthopaed Hosp, Implant Biomech Lab, Los Angeles, CA USA
[2] Univ Calif Los Angeles, Dept Orthopaed Surg, Los Angeles, CA 90024 USA
关键词
D O I
10.1080/17453670810016812
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose Hip resurfacing arthroplasty has had resurgence recently and is now a popular option for younger, active patients. We used an in vitro model to assess range of motion and impingement pro. le for hip resurfacing and compared them to those for conventional total hip arthroplasty. Methods 8 different hip replacement designs were implanted into adult composite femurs and pelvises. These were mounted onto a 3-dimensional compass allowing all motions, with the degrees and impingement recorded. The designs tested were the Conserve Plus Hip Resurfacing System, Depuy ASR, Birmingham Hip Resurfacing System, Charnley, McKee-Farrar metal-on-metal, SROM Hip metal-on-metal, SROM Hip metal-on-polyethylene, Prodigy metal-on-metal, and also a native intact composite femur and pelvic articulation. Femoral stems were tested at 0 and 20 degrees of anteversion. Results Conventional hip arthroplasty exhibited statistically significantly greater range of motion than resurfacing arthroplasty. Resurfacing showed neck impingement in 29/30 motions. Conventional arthroplasties showed femoral neck impingement in 41/100 motions. Interpretation In situ range of motion of resurfacing arthroplasty was less than that of conventional total hip arthroplasty. Resurfacing systems impinged almost entirely on the femoral neck, while conventional hip arthroplasties had a varied impingement profile. Our findings raise concern for early neck-on-cup impingement, which may cause component loosening and femoral neck fracture, both of which are observed after hip resurfacing.
引用
收藏
页码:755 / 762
页数:8
相关论文
共 15 条
[1]
ALBERTON GM, 2004, J BONE JOINT SURG AM, V12, P314
[2]
Amstutz H C, 1998, J Orthop Sci, V3, P169, DOI 10.1007/s007760050038
[3]
AMSTUTZ HC, 1975, CLIN ORTHOP RELAT R, P124
[4]
AMSTUTZ HC, 1996, METAL METAL HIP PROS, pS2
[5]
The influence of head and neck geometry on stability of total hip replacement - A mechanical test study [J].
Bader, R ;
Scholz, R ;
Steinhauser, E ;
Zimmermann, S ;
Busch, R ;
Mittelmeier, W .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (04) :415-421
[6]
Early results of conversion of a failed femoral component in hip resurfacing arthroplasty [J].
Ball, Scott T. ;
Le Duff, Michel J. ;
Amstutz, Harlan C. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (04) :735-741
[7]
Random inelasticity and velocity fluctuations in a driven granular gas [J].
Barrat, A ;
Trizac, E .
EUROPEAN PHYSICAL JOURNAL E, 2003, 11 (01) :99-104
[8]
CHANDLER DR, 1982, CLIN ORTHOP RELAT R, P284
[9]
Mechanical validation of whole bone composite femur models [J].
Cristofolini, L ;
Viceconti, M ;
Cappello, A ;
Toni, A .
JOURNAL OF BIOMECHANICS, 1996, 29 (04) :525-535
[10]
Dual energy X-ray absorptiometry analysis of peri-prosthetic stress shielding in the Birmingham resurfacing hip replacement [J].
Harty, JA ;
Devitt, B ;
Harty, LC ;
Molloy, M ;
McGuinness, A .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (10) :693-695